L3Campus Stackable Managed Switch
«
Caractéristiques
- Modèle : Omada Campus Stackable L3 Managed Switch
- Front Panel: Mode Selection Button, Management Port, LED,
Console Port USB2.0 Port (Type-C/RJ45), 1G RJ45 Port, 10G SFP+ Slot
DIRIGÉ - Indication LED:
- PWR1*: Green On (switch powered by PWR1), Off (PWR2
disconnected or not working properly) - PWR2: Green On (switch powered by PWR1 and PWR2 connected),
Yellow On** (PWR2 powered), Off (PWR1 disconnected or not working
correctement) - LED SYS FAN: Green On (all fans work properly), Yellow On (not
all fans work properly) - MGMT: On (device linked to port), Flashing (transmitting or
receiving data), Off (no device linked to port) - MST: On (device linked to port), Flashing (transmitting or
receiving data), Off (no device linked to port)
- PWR1*: Green On (switch powered by PWR1), Off (PWR2
Instructions d'utilisation du produit
Chapitre 2 : Installation
Avant de commencer le processus d'installation, assurez-vous d'avoir tous
the necessary tools and follow safety precautions.
- Contenu du colis : Check all items mentioned in
le paquet. - Précautions de sécurité : Suivez les directives pour
assurer une installation sûre. - Outils d'installation : Gather all tools required
pour l'installation. - Installation du produit: Suivez pas à pas
instructions provided in the manual for successful
installation.
Chapitre 3: Connexion
After installation, connect the switch to the network using
appropriate cables and ports as per your network setup.
Chapitre 4: Configuration
Configure the switch based on your requirements. You can choose
between Standalone Mode or Controller Mode as per your network
besoins.
FAQ
Q: What should I do if the LED indications show an error?
A: If the LED indications suggest improper functioning, check
the power sources and connections. Refer to the troubleshooting
section du manuel pour obtenir de l'aide.
« `
Solution de réseautage d'entreprise
Guide d'installation
Omada Campus Stackable L3 Managed Switch
À propos de ce guide d'installation
Ce guide d'installation décrit les caractéristiques matérielles, les méthodes d'installation et les points à prendre en compte lors de l'installation. Ce guide d'installation est structuré comme suit : Chapitre 1 Introduction Ce chapitre décrit les composants externes du commutateur. Chapitre 2 Installation Ce chapitre explique comment installer le commutateur. Chapitre 3 Connexion Ce chapitre explique comment effectuer la connexion physique du commutateur. Chapitre 4 Configuration Ce chapitre explique comment configurer le commutateur. Annexe A Dépannage Annexe B Spécifications
Public
Ce guide d'installation est destiné:
Ingénieur réseau
Administrateur réseau
Conventions
Certains modèles présentés dans ce guide peuvent être indisponibles dans votre pays ou région. Pour plus d'informations sur les ventes locales, consultez le site https://www.omadanetworks.com/.
· Les figures des chapitres 2, 3 et 4 sont uniquement à des fins de démonstration. L'apparence de votre commutateur peut différer de celle illustrée.
· Les calculs du budget PoE sont basés sur des tests en laboratoire. Le budget d’alimentation PoE réel n’est pas garanti et varie en fonction des limites du client et de facteurs environnementaux.
· Ce guide utilise les formats spécifiques pour mettre en évidence les messages spéciaux. Le tableau suivant répertorie les icônes de notification utilisées dans ce guide.
Rappelez-vous d'être prudent. Un avertissement indique un potentiel qui peut endommager l'appareil.
Rappelez-vous de prendre note. La note contient les informations utiles pour une meilleure utilisation du produit.
Document connexe
Le Guide de l'utilisateur et le Guide de référence CLI du produit sont fournis sur le Centre de téléchargement. Pour obtenir les dernières informations sur le produit, visitez le site officiel website : https://support.omadanetworks.com/document/.
Contenu
Chapitre 1 Introduction ———————- 01
1.1 Produit terminéview …………………………………………………..01 1.2 Aspect……………………………………………………………..01
Chapitre 2 Installation ———————- 12
2.1 Contenu de l'emballage ………………………………………………….12 2.2 Précautions de sécurité …………………………………………………12 2.3 Outils d'installation ……………………………………………………..14 2.4 Installation du produit ………………………………………………..14
Chapitre 3 Connexion ———————- 22
3.1 Ethernet Port …………………………………………………………..22 3.2 10G SFP+/25G SFP28/100G QSFP28 Slot ………..22 3.3 Console Port ……………………………………………………………22 3.4 Verify Installation…………………………………………………….23 3.5 Power On ………………………………………………………………….24 3.6 Initialization………………………………………………………………24 3.7 Stack Topology ……………………………………………………….24
Chapitre 4 Configuration ——————– 27
4.1 Configuration terminéeview…………………………………………27 4.2 Mode autonome……………………………………………………27 4.3 Mode contrôleur……………… ………………………………………28
Annexe A Dépannage —————- 32
Annexe B Spécifications —————— 33
Omada Campus Stackable L3 Managed Switch
Chapitre 1 Introduction
1.1 Produit terminéview
Conçu pour les entreprises et les campus, Omada Campus Stackable L3 Managed Switch provides wire-speed performance and abundant L2 and L3 management features. It provides a variety of service features and multiple powerful functions with high security. The EIA-standardized framework and smart configuration capacity can provide flexible solutions for a variable scale of networks. Static Routing, RIP, OSPF, BGP, IS-IS, PIM-SM/DM/SSM, and ECMP come with abundant Layer 3 routing protocols that support a scalable network. Physically stacking for builtin redundancy and performance. Redundant power supplies and fans make it an ideal choice for reliable networking architecture. VRRP allows a group of switches to dynamically back up each other. ERPS supports rapid protection and recovery in a ring topology. MACsec, secure boot, ACL, 802.1x and Dynamic ARP Inspection provide robust security strategies. QoS and IGMP snooping/filtering optimize voice and video application. Link aggregation (LACP) increases aggregated bandwidth, optimizing the transport of business critical data. SNMP, RMON, WEB, Netconf and CLI Log-in bring abundant management policies. These switches integrate multiple functions with excellent performance, and is friendly to manage, which can fully meet the need of the users demanding higher networking performance. S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is also a Power Sourcing Equipment (PSE*). The RJ45 ports that support Power over Ethernet (PoE*) function can automatically detect and supply power to those powered devices (PDs*) complying with IEEE 802.3af, IEEE 802.3at, and IEEE 802.3bt (only for S6500-24MPP4Y/S6500-48MPP6Y). *PSE: a device (switch or hub for instance) that provides power through an Ethernet cable. *PoE: This technology describes a system to transmit electrical power, along with data, to remote devices over standard twisted-pair cable in an Ethernet. *PD: a device powered by a PSE and thus consumes energy. ExampLes fichiers incluent l'alimentation des caméras réseau, des points d'accès LAN sans fil, des téléphones IP, des concentrateurs réseau, des ordinateurs embarqués, etc.
1.2 Apparence
Front Panel (The figure is for demonstration only. It may differ from your actual product. )
The front panel of S6500-24G4XF is shown as the following figure.
Bouton de sélection de mode
Port de gestion
DIRIGÉ
Port de console Port USB2.0 (Type-C/RJ45)
Port RJ1 45G
10G SFP+ Slot LED
The front panel of S6500-48G6XF is shown as the following figure.
Bouton de sélection de mode
Port de gestion
DIRIGÉ
Port de console Port USB2.0 (Type-C/RJ45)
Port RJ1 45G
10G SFP+ Slot LED
Introduction 01
Omada Campus Stackable L3 Managed Switch
Indication LED
REP1*
REP2
Vert allumé
Désactivé
Vert allumé
Jaune allumé**
Désactivé
Vert allumé
Désactivé
Désactivé
Indication
Le commutateur est alimenté par PWR1. PWR2 est déconnecté ou fonctionne mal.
Le commutateur est alimenté par PWR1. PWR1 et PWR2 sont connectés.*
Le commutateur est alimenté par PWR2. PWR1 est déconnecté ou fonctionne mal.
L'interrupteur est éteint ou PWR1 et PWR2 fonctionnent mal.
LED SYS FAN
GESTION
MST
Port 1-24 of S6500-24G4XF/ Port 1-48 of S6500-48G6XF
(Lorsque la LED SPEED est allumée)
Port 1-24 of S6500-24G4XF/ Port 1-48 of S6500-48G6XF
(Lorsque la LED STK est allumée)
Port 25-28 of S6500-24G4XF/ Port 49-54 of S6500-48G6XF ***
Indication
Clignotant : l'interrupteur fonctionne correctement. On ou Off : l'interrupteur ne fonctionne pas correctement.
Vert allumé : Tous les ventilateurs fonctionnent correctement. Jaune allumé : tous les ventilateurs ne fonctionnent pas correctement.
Allumé : un périphérique est lié au port. Clignotant : transmission ou réception de données. Éteint : aucun périphérique n'est lié au port.
Activé : l'appareil fonctionne comme commutateur principal dans la topologie de pile ou individuellement. Désactivé : l'appareil fonctionne comme commutateur membre dans la topologie de pile.
Vert allumé : Fonctionnement à 1000 1000 Mbit/s, mais aucune activité. Vert clignotant : fonctionne à 10 100 Mbps et transmet ou reçoit des données. Jaune allumé : Fonctionnement à 10 Mbps/100 Mbps, mais aucune activité. Jaune clignotant : fonctionne à XNUMX Mbps/XNUMX Mbps et transmet ou reçoit des données. Éteint : Aucun appareil n'est lié au port correspondant.
Activé : le numéro de port indique l'ID de l'unité dans la topologie de la pile.
Vert allumé : fonctionne à 10 Gbit/s, mais aucune activité. Vert clignotant : fonctionne à 10 Gbit/s et transmet ou reçoit des données. Jaune allumé : Fonctionnement à 1 Gbit/s, mais aucune activité. Jaune clignotant : fonctionne à 1 Gbit/s et transmet ou reçoit des données. Éteint : Aucun appareil n'est lié au port correspondant.
*PWR1 is the primary power supply and it takes priority over PWR2. When the device is powered by PWR1, PWR2 will be working in the backup mode.
**Lorsque PWR1 et PWR2 fonctionnent correctement et que l'interrupteur est alimenté par PWR1, il faut 10 à 20 secondes pour que la LED PWR2 (jaune) s'éteigne une fois que PWR2 est débranché.
***All 10 Gbps SFP+ slots can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.
02 Introduction
Omada Campus Stackable L3 Managed Switch The front panel of S6500-24GP4XF is shown as the following figure.
Bouton de sélection de mode
Port de gestion
Port de console LED Port USB2.0 (Type-C/RJ45)
Port RJ1 45G
10G SFP+ Slot LED
Le panneau avant du S6500-48GP6XF est illustré comme la figure suivante.
Bouton de sélection de mode
Port de gestion
Port de console LED Port USB2.0 (Type-C/RJ45)
Port RJ1 45G
10G SFP+ Slot LED
The front panel of S6500-24M4Y is shown as the following figure.
Bouton de sélection de mode
Port de gestion
Port de console LED Port USB2.0 (Type-C/RJ45)
Port RJ2.5 45G
25G SFP28 Slot LED
The front panel of S6500-24MPP4Y is shown as the following figure.
Bouton de sélection de mode
Port de gestion
Port de console LED Port USB2.0 (Type-C/RJ45)
Port RJ2.5 45G
25G SFP28 Slot LED
Introduction 03
Omada Campus Stackable L3 Managed Switch The front panel of S6500-48M6Y is shown as the following figure.
Bouton de sélection de mode
Port de gestion
Port de console LED Port USB2.0 (Type-C/RJ45)
Port RJ2.5 45G
The front panel of S6500-48MPP6Y is shown as the following figure.
25G SFP28 Slot LED
Bouton de sélection de mode
Port de gestion
Port de console LED Port USB2.0 (Type-C/RJ45)
Port RJ2.5 45G
25G SFP28 Slot LED
LED Indication LED
REP1* REP2
SYS FAN PoE MAX
(For S6500-24GP4XF, S6500-48GP6XF, S6500-24MPP4Y, S6500-48MPP6Y)
GESTION
MST
Indication
Green On: The power supply works properly. Green Flashing: The power supply module is not plugged in properly or not compatible with the switch. Yellow On: The power supply works properly but the switch is powered by the other power supply.** Yellow Flashing: The power supply module is plugged in properly but there’s is no AC power input; abnormal power supply. Off: No power supply module is inserted.
Clignotant : l'interrupteur fonctionne correctement. On ou Off : l'interrupteur ne fonctionne pas correctement.
Vert allumé : Tous les ventilateurs fonctionnent correctement. Jaune allumé : tous les ventilateurs ne fonctionnent pas correctement.
Allumé : la puissance PoE restante est de 7 W. Clignotant : la puissance PoE restante reste de 7 W après que cette LED soit allumée pendant 2 minutes. Éteint : la puissance PoE restante est > 7 W.
Allumé : un périphérique est lié au port. Clignotant : transmission ou réception de données. Éteint : aucun périphérique n'est lié au port.
Activé : l'appareil fonctionne comme commutateur principal dans la topologie de pile ou individuellement. Désactivé : l'appareil fonctionne comme commutateur membre dans la topologie de pile.
04 Introduction
Omada Campus Stackable L3 Managed Switch
DIRIGÉ
Indication
Port 1-24 of S6500-24GP4XF/
Port 1-48 of S6500-48GP6XF
(Lorsque la LED SPEED est allumée)
Vert allumé : Fonctionnement à 1000 1000 Mbit/s, mais aucune activité. Vert clignotant : fonctionne à 10 100 Mbps et transmet ou reçoit des données. Jaune allumé : Fonctionnement à 10 Mbps/100 Mbps, mais aucune activité. Jaune clignotant : fonctionne à XNUMX Mbps/XNUMX Mbps et transmet ou reçoit des données. Éteint : Aucun appareil n'est lié au port correspondant.
Port 1-24 of S6500-24M4Y & S6500-24MPP4Y/
Port 1-48 of S6500-48M6Y & S6500-48MPP6Y
(Lorsque la LED SPEED est allumée)
Green On: Running at 2.5 Gbps, but no activity. Green Flashing: Running at 2.5 Gbps and transmitting or receiving data. Yellow On: Running at 10 Mbps/100 Mbps/1000 Mbps, but no activity. Yellow Flashing: Running at 10 Mbps/100 Mbps/1000 Mbps and transmitting or receiving data. Off: No device is linked to the corresponding port.
Port 1-24 of S6500-24GP4XF, S6500-24M4Y &
S6500-24MPP4Y/
Port 1-48 of S6500-48GP6XF, S6500-48M6Y &
S6500-48MPP6Y
(Lorsque la LED STK est allumée)
Activé : le numéro de port indique l'ID de l'unité dans la topologie de la pile.
Port 1-24 of S6500-24GP4XF & S6500-24MPP4Y/
Port 1-48 of S6500-48GP6XF & S6500-48MPP6Y
(Lorsque le voyant PoE est allumé)
Green On: The port is supplying power normally. Green Flashing: The supply power exceeds the correponding port’s maximum power. Yellow On: Overload or short circuit is detected. Off: Not providing PoE power on the port
Port 25-28 of S6500-24GP4XF/ Port 49-54 of S6500-48GP6XF ***
Vert allumé : fonctionne à 10 Gbit/s, mais aucune activité. Vert clignotant : fonctionne à 10 Gbit/s et transmet ou reçoit des données. Jaune allumé : Fonctionnement à 1 Gbit/s, mais aucune activité. Jaune clignotant : fonctionne à 1 Gbit/s et transmet ou reçoit des données. Éteint : Aucun appareil n'est lié au port correspondant.
Port 25-28 of S6500-24M4Y & S6500-24MPP4Y/
Port 49-54 of S6500-48M6Y & S6500-48MPP6Y***
Vert allumé : fonctionne à 25 Gbit/s, mais aucune activité. Vert clignotant : fonctionne à 25 Gbit/s et transmet ou reçoit des données. Jaune allumé : Fonctionnement à 1 Gbit/s/10 Gbit/s, mais aucune activité. Jaune clignotant : fonctionne à 1 Gbit/s/10 Gbit/s et transmet ou reçoit des données. Éteint : Aucun appareil n'est lié au port correspondant.
*By default, S6500-24GP4XF is shipped with a PSM500-AC power supply module, S6500-24M4Y/S650048M6Y is shipped with a PSM550-AC power supply module, and S6500-48GP6XF/S6500-24MPP4Y/ S6500-48MPP6Y is shipped with a PSM900-AC power supply module. One more power supply module needs to be purchased separately.
**By default, both PWR1 and PWR2 will work simultaneously in the load sharing mode. They can also work simultaneously in the redundant power supply mode: for S6500-24GP4XF/S6500-48GP6XF/S650024MPP4Y/S6500-48MPP6Y, you can specify the primary power supply and the backup power supply according to your needs; for S6500-24M4Y/S6500-48M6Y, you can only set PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
***All 10 Gbps SFP+ slots and 25 Gbps SFP28 slots can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.
Introduction 05
Omada Campus Stackable L3 Managed Switch The front panel of S7500-26XF6Y is shown as the following figure.
Port de gestion
DIRIGÉ
Port de consolePort USB3.0
(RJ45/Type-C)
Sélection du mode
Bouton
10G SFP+ Slot (Port 1-26)
The front panel of S7500-48XF4C is shown as the following figure.
LED 25G SFP28 Slot (Port 27-32)
Bouton de sélection de mode
Port de gestion
Port de console LED Port USB3.0 (Type-C/RJ45)
10G SFP+ Slot (Port 1-48)
The front panel of S7500-24Y4C is shown as the following figure.
100G QSFP28 Slot LED (Port 49-52)
Port de gestion
DIRIGÉ
Port USB3.0
Port de console
(RJ45/Type-C)
Bouton de sélection de mode
Emplacement SFP25 28G
DIRIGÉ
(Ports 1-24)
The front panel of S7500-48Y8C is shown as the following figure.
Emplacement QSFP100 28G (ports 25-28)
LED Mode Selection Button
25G SFP28 Slot (Port 1-48)
06 Introduction
Emplacement QSFP100 28G (ports 49-56)
Omada Campus Stackable L3 Managed Switch The front panel of S7500-32C is shown as the following figure.
Bouton de sélection de mode
Voyant du port de gestion
Port USB3.0
Console Port (Type-C/RJ45)
Emplacement QSFP100 28G
DIRIGÉ
Note: S7500-24Y4C and S7500-48Y8C are designed for installation in Network Telecommunications Facilities (NTFs) where ambient temperature and humidity are controlled.
LED Indication LED
REP1* REP2
VENTILATEUR DU SYSTÈME
GESTION
MST
Port 1-26 of S7500-26XF6Y/ Port 1-48 of S7500-48XF4C
(Lorsque la LED SPD est allumée)
Port 1-24 of S7500-24Y4C/ Port 1-48 of S7500-48Y8C
(When the SPD/SPEED LED is on)
Indication
Green On: The power supply works properly. Green Flashing: The power supply module is not plugged in properly or not compatible with the switch. Yellow On: The power supply works properly but the switch is powered by the other power supply.** Yellow Flashing: The power supply module is plugged in properly but there’s is no AC power input; abnormal power supply. Off: No power supply module is inserted.
Clignotant : l'interrupteur fonctionne correctement. On ou Off : l'interrupteur ne fonctionne pas correctement.
Vert : Tous les ventilateurs fonctionnent correctement. Jaune : Tous les ventilateurs ne fonctionnent pas correctement.
Allumé : un périphérique est lié au port. Clignotant : transmission ou réception de données. Éteint : aucun périphérique n'est lié au port.
Note:
For S7500-48Y8C, this LED lights green at 1 Gbps and orange at sub-1 Gbps.
Activé : l'appareil fonctionne comme commutateur principal dans la topologie de pile ou individuellement. Désactivé : l'appareil fonctionne comme commutateur membre dans la topologie de pile.
Vert allumé : fonctionne à 10 Gbit/s, mais aucune activité. Vert clignotant : fonctionne à 10 Gbit/s et transmet ou reçoit des données. Jaune allumé : Fonctionnement à 1 Gbit/s, mais aucune activité. Jaune clignotant : fonctionne à 1 Gbit/s et transmet ou reçoit des données. Éteint : Aucun appareil n'est lié au port correspondant.
Vert allumé : fonctionne à 25 Gbit/s, mais aucune activité. Vert clignotant : fonctionne à 25 Gbit/s et transmet ou reçoit des données. Jaune allumé : Fonctionnement à 1 Gbit/s/10 Gbit/s, mais aucune activité. Jaune clignotant : fonctionne à 1 Gbit/s/10 Gbit/s et transmet ou reçoit des données. Éteint : Aucun appareil n'est lié au port correspondant.
Introduction 07
Omada Campus Stackable L3 Managed Switch
DIRIGÉ
Indication
Port 27-32 of S7500-26XF6Y ***
(Lorsque la LED SPD est allumée)
Vert allumé : fonctionne à 25 Gbit/s, mais aucune activité. Vert clignotant : fonctionne à 25 Gbit/s et transmet ou reçoit des données. Jaune allumé : Fonctionnement à 1 Gbit/s/10 Gbit/s, mais aucune activité. Jaune clignotant : fonctionne à 1 Gbit/s/10 Gbit/s et transmet ou reçoit des données. Éteint : Aucun appareil n'est lié au port correspondant.
Port 49-52 of S7500-48XF4C/
Port 25-28 of S7500-24Y4C/ Port 49-56 of S7500-48Y8C/ Port 1-32 of S7500-32C***
(When the SPD/SPEED LED is on)
Vert allumé : fonctionne à 100 Gbit/s, mais aucune activité. Vert clignotant : fonctionne à 100 Gbit/s et transmet ou reçoit des données. Jaune allumé : Fonctionnement à 40 Gbit/s, mais aucune activité. Jaune clignotant : fonctionne à 40 Gbit/s et transmet ou reçoit des données. Éteint : Aucun appareil n'est lié au port correspondant.
Note:
For S7500-48XF4C/S7500-48Y8C/S7500-32C, the indication above applies only when the 100 Gbps QSFP28 slots work with common cables. When the slots work with 1-to-4 breakout cables, a single slot is split into four 25 Gbps interfaces. In such scenario, the LED will light green only when all four interfaces are working at 25 Gbps (maximum speed), otherwise it will light yellow. When no device is connected to any of the four interfaces, the LED will be off. (The 100 Gbps QSFP28 slots will support 1-to-4 breakout cables in a future software release.)
Port 1-32 of S7500-26XF6Y/
Port 1-48 of S7500-48XF4C/ Port 1-28 of S7500-24Y4C/ Port 1-56 of S7500-48Y8C
(Lorsque la LED STK est allumée)
Activé : le numéro de port indique l'ID de l'unité dans la topologie de la pile.
*By default, S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S7500-32C is shipped with a PSM550-AC power supply module installed respectively. One more power supply module needs to be purchased separately. **By default, both PWR1 and PWR2 will work simultaneously in the load sharing mode. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply. ***All 25 Gbps SFP28 slots of S7500-26XF6Y and 100 Gbps QSFP28 slots of S7500-48XF4C/S7500-24Y4C/ S7500-48Y8C/S7500-32C can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.
Port Introduction (The Management Port, Console Ports, and USB Ports of S7500-48Y8C are located on the rear panel.)
Port de gestion Conçu pour connecter l'appareil pour la gestion via web, CLI or SNMP. Do not connect this port to any outdoor device, as this may induce surge and lightning damage. Console Port Designed to connect with a computer for monitoring and configuring the switch. When the switch has an RJ45 console port and a Type-C console port, console input is active on only one console port at a time. By default, the Type-C connector takes priority over the RJ45 connector, or you can change the priority through the web. Do not connect this port to any outdoor device, as this may induce surge and lightning damage. USB Port Designed to install the USB flash disk for data storage. 1000M RJ45 Port Designed to connect to the device with a bandwidth of 10Mbps, 100 Mbps or 1000 Mbps. For PoE switches, the port can also provide power for PDs.
08 Introduction
Omada Campus Stackable L3 Managed Switch
2.5G RJ45 Port Designed to connect to the device with a bandwidth of 10 Mbps, 100 Mbps, 1000 Mbps or 2.5 Gbps. For PoE switches, the port can also provide power for PDs. 10G SFP+ Slot Designed to install the 10 Gbps/1 Gbps optical module. 25G SFP28 Slot Designed to install the 25 Gbps/10 Gbps/1 Gbps optical module. 100G QSFP28 Slot Designed to install the 100 Gbps/40 Gbps optical module. Port Feature
Modèle
1000 millions
2.5G 10G SFP+ 25G SFP28 100G QSFP28 Management Console USB
RJ45 Port RJ45 Port Slot
Fente
Fente
Port
Port Port
S6500-24G4XF
24
/
4
/
/
S6500-48G6XF
48
/
6
/
/
S6500-24GP4XF
24
/
4
/
/
S6500-48GP6XF
48
/
6
/
/
S6500-24M4Y
/
24
/
4
/
S6500-24MPP4Y
/
24
/
4
/
S6500-48M6Y
/
48
/
6
/
S6500-48MPP6Y
/
48
/
6
/
S7500-26XF6Y
/
/
26
6
/
S7500-48XF4C
/
/
48
/
4
S7500-24Y4C
/
/
/
24
4
S7500-48Y8C
/
/
/
48
8
S7500-32C
/
/
/
/
32
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
Rear Panel (The figure is for demonstration only. It may differ from your actual product. )
The rear panel of S6500-24G4XF/S6500-48G6XF is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.
Kensington Security Slot Grounding Terminal Power Socket
Locking Strap Slot
Remarque : PWR1 est l'alimentation principale et elle est prioritaire sur PWR2.
Introduction 09
Omada Campus Stackable L3 Managed Switch
The rear panel of S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.
Fente de sécurité Kensington
DIRIGÉ
Borne de mise à la terre
Module d'alimentation électrique
DIRIGÉ
Locking Strap Slot
Note: By default, S6500-24GP4XF is shipped with a PSM500-AC power supply module, and S650048GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is shipped with a PSM900-AC power supply module. One more power supply module needs to be purchased separately. Both PWR 1 and PWR2 can work simultaneously, or you can specify the primary power supply and the backup power supply according to your needs. Generally, the primary power supply takes priority over the backup power supply.
The rear panel of S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.
Borne de mise à la terre
DIRIGÉ
Power Supply Module Locking Strap Slot
DIRIGÉ
Fente de sécurité Kensington
Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode: for S6500-24M4Y/S6500-48M6Y, you can only set PWR1 as the primary power supply and PWR2 as the backup power supply; for S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C, you can specify the primary power supply and the backup power supply according to your needs; Generally, the primary power supply takes priority over the backup power supply.
Le panneau arrière du S7500-48Y8C est illustré ci-dessous. Cette illustration est fournie à titre de démonstration uniquement. L'apparence de votre commutateur peut différer de celle illustrée.
Borne de mise à la terre
DIRIGÉ
DIRIGÉ
Sangle de verrouillage
Fente
Module d'alimentation électrique
10 Introduction
ManagemeC(nTtoyPnposeor-tCle/RPJoU4rt5S)B3P.o0wPeorrSt upplyLoMcokdiSnulgoletStraLpED
Omada Campus Stackable L3 Managed Switch
Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
The rear panel of S7500-32C is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.
DEL DEL
Locking Strap Slot
Module d'alimentation Emplacement de sécurité Kensington
Borne de mise à la terre
DIRIGÉ
Locking Strap Slot
Module d'alimentation électrique
Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
Power Supply Module The pluggable power supply module PSM500-AC/PSM900-AC/PSM550-AC is an AC-input power supply module. It can convert the input voltage to 53.5 V (12 V for PSM550-AC) with the maximum output power of 500 W/900 W/550 W respectively. Kensington Security Slot Secure the lock (not provided) into the security slot to prevent the device from being stolen.
Grounding Terminal The switch already comes with lightning protection mechanism. You can also ground the switch through the PE (Protecting Earth) cable of AC cord or with Ground Cable. For detailed lightning protection measures, refer to the Lightning Protection Guide from: https://support.omadanetworks.com/r/1004/. Locking Strap Slot Remove the instruction label and insert the AC power cable locking strap into the slot to secure the power cable.
Introduction 11
Omada Campus Stackable L3 Managed Switch
Chapitre 2 Installation
2.1 Contenu du paquet
Assurez-vous que le paquet contient les éléments suivants. Veuillez contacter votre distributeur si l'un des éléments répertoriés est endommagé ou manquant. Les chiffres sont uniquement à titre de démonstration. Les articles réels peuvent différer en apparence et en quantité de ceux représentés.
Changer
Cordon d'alimentation et câble de console
Guide d'installation
Solution de réseautage d'entreprise
Guide d'installation
Omada Campus Stackable L3 Managed Switch
Supports de montage, vis et pieds en caoutchouc
2.2 Précautions de sécurité
Pour éviter tout dommage à l'appareil et toute blessure corporelle causée par une mauvaise utilisation, vous devez respecter les règles suivantes.
Précautions de sécurité Gardez l'appareil hors tension pendant l'installation. Portez un bracelet antistatique et assurez-vous que le bracelet est en bon contact avec la peau et qu'il est
bien fondé. Utilisez uniquement le cordon d'alimentation fourni avec l'interrupteur. Assurez-vous que le volume d'alimentationtage correspond aux spécifications indiquées sur le panneau arrière du
changer. Assurez-vous que l'interrupteur est installé dans un environnement bien ventilé et que son trou de ventilation n'est pas
bloqué. N'ouvrez pas et ne retirez pas le couvercle de l'interrupteur. Avant de nettoyer l'appareil, coupez l'alimentation électrique. Ne le nettoyez pas avec un chiffon légèrement aqueux et ne
use any other liquid cleaning method. Place the device with its bottom surface facing downwards. Only instructed person or skilled person can be allowed to install, replace, or service this device.
Exigences du site
Température/Humidité
12 Installation
Omada Campus Stackable L3 Managed Switch Keep the equipment room at an appropriate level of temperature and humidity. Too much or too little humidity may lead to bad insulation, leakage of electricity, mechanical property changes, and corrosion. High temperatures may accelerate aging of the insulation materials, significantly shortening the service life of the device. To find out the best temperature and humidity conditions for the device, check the Appendix B Specifications. Clearness
La poussière accumulée sur l'interrupteur peut être absorbée par l'électricité statique et entraîner un mauvais contact des points de contact métalliques. Certaines mesures ont été prises pour empêcher l'électricité statique, mais une électricité statique trop forte peut causer des dommages mortels aux éléments électroniques du circuit imprimé interne. Pour éviter l'effet de l'électricité statique sur le fonctionnement de l'interrupteur, accordez une grande importance aux éléments suivants : Dépoussiérez régulièrement l'appareil et gardez l'air intérieur propre. Gardez l'appareil bien mis à la terre et assurez-vous que l'électricité statique a été transférée. Interférence électromagnétique
Les éléments électroniques, notamment la capacité et l'inductance du dispositif, peuvent être affectés par des interférences externes, telles que l'émission conduite par couplage capacitif, couplage par inductance et couplage par impédance. Pour réduire les interférences, veillez à prendre les mesures suivantes : Utilisez une alimentation capable de filtrer efficacement les interférences du réseau électrique. Gardez l'appareil loin des appareils à haute fréquence et à fort courant tels que les transmissions radio.
gare. Utilisez un blindage électromagnétique si nécessaire. Protection contre la foudre
Installation 13
Omada Campus Stackable L3 Managed Switch
Vol extrêmement élevétagLes courants peuvent être produits instantanément en cas de foudre et l'air dans le trajet de décharge électrique peut être instantanément chauffé jusqu'à 20,000 XNUMX °C. Comme ce courant instantané est suffisamment puissant pour endommager les appareils électroniques, des mesures de protection contre la foudre plus efficaces doivent être prises. Assurez-vous que le rack et l'appareil sont bien mis à la terre. Assurez-vous que la prise de courant a un bon contact avec le sol. Conservez un système de câblage raisonnable et évitez la foudre induite. Utilisez le signal SPD (dispositif de protection contre les surtensions) lors du câblage à l'extérieur.
Remarque : Pour des mesures détaillées de protection contre la foudre, reportez-vous au Guide de protection contre la foudre à l'adresse : https://support.omadanetworks.com/r/1004/. Site d'installation
Lors de l'installation de l'appareil sur un rack ou un établi plat, accordez une grande importance aux éléments suivants : Installez l'appareil avec sa surface inférieure tournée vers le bas uniquement. Cet équipement ne convient pas à une utilisation dans des endroits où des enfants sont susceptibles d'être présents. Le support ou l'établi est plat, stable et suffisamment robuste pour supporter un poids d'au moins 9.5 kg. Le rack ou l'établi dispose d'un bon système de ventilation. Le local technique est bien ventilé. Le rack est bien mis à la terre. Gardez l'appareil à moins de 1.5 mètres de la prise de courant.
2.3 Outils d'installation
Tournevis Phillips Enveloppe de poignet antistatique Câbles
Remarque : ces outils ne sont pas inclus avec notre produit. Si nécessaire, vous pouvez les acheter séparément.
2.4 Installation du produit
Le commutateur est conçu avec une fonction de dissipation thermique d’avant en arrière. Lorsqu'il fonctionne, l'air circule comme indiqué ci-dessous. Pour une meilleure dissipation de la chaleur, veuillez installer l'appareil dans un environnement bien ventilé et laisser un espace de 5 à 10 cm autour de l'appareil.
14 Installation
Figure 2-1
Circulation d'air
Omada Campus Stackable L3 Managed Switch
Installation sur le bureau
Pour installer l'appareil sur le bureau, suivez les étapes :
1. Placez l'appareil sur une surface plane suffisamment solide pour supporter tout le poids de l'appareil avec tous les accessoires.
2. Retirez les papiers adhésifs des pieds en caoutchouc.
3. Fixez les pieds en caoutchouc au bas de l'appareil pour éviter qu'il ne glisse lorsqu'il est placé sur un bureau.
Figure 2-2
Installation sur le bureau
Pieds en bas de l'appareil Encoche
Installation en rack
Le paquet comprend 6 paires de supports de montage en rack différents, leurs images sont illustrées ci-dessous et peuvent différer des produits réels.
Figure 2-3
Supports de montage
Groupe de trous de vis 2
Bracket D Bracket C Bracket B Bracket A
Groupe de trous de vis 1
Groupe de trous de vis 3
Support F
Screw Hole Group 4-2 (for device with 420mm depth)
Groupe de trous de vis 5
Trou de vis
Groupe 4-1
Screw Hole Group 4-3
(for device with 380mm depth)
(for device with
460mm depth)
Support E
Installation 15
Omada Campus Stackable L3 Managed Switch
Before installing the device in an EIA standard-sized, 19-inch rack, please check the efficiency of the grounding system and the stability of the rack, then wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded. Bracket B, C & E have two adjustable ears, please measure the distance between the front-post rack and the rear-post rack, and determine a suitable mounting method from below:
Méthode
Démonstration
Front: Bracket A Rear: Bracket D (Screw Hole Group 1) + Bracket B (Ear towards back)
Distance des racks
(Pour appareil d'une profondeur de 380 mm)
Distance des racks
(Pour appareil d'une profondeur de 420 mm)
Distance des racks
(Pour appareil d'une profondeur de 460 mm)
498-640mm 538-680mm 578-720mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 1) + Bracket C (Ear towards back)
477-498mm 517-538mm 557-578mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket C (Ear towards back)
429-477mm 469-517mm 509-557mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket C (Ear towards front)
410-429mm 450-469mm 490-509mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 3) + Bracket C (Ear towards back)
357-410mm 397-450mm 437-490mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket B (Ear towards back)
282-410mm 322-450mm 362-490mm
16 Installation
Omada Campus Stackable L3 Managed Switch
Front: Bracket A Rear: Bracket F (Screw Hole Group 4) + Bracket E (Ear towards back)
555-936mm 555-936mm 555-936mm
Front: Bracket A Rear: Bracket F (Screw Hole Group 5) + Bracket E (Ear towards back)
743-1121mm 743-1121mm 743-1121mm
Pour installer l'appareil, suivez les instructions décrites ci-dessous :
1. Fixez les écrous M6 aux racks.
Figure 2-4
Fixation des écrous M6
×8
2. Attach the mounting brackets (B, C or E) to the rear-post racks and secure them with the provided M6 screws, as illustrated in the following figure.
Figure 2-5
Installation des supports sur les racks
or
3. Attach the brackets A & D/F to the switch with the provided M3 screws.
Installation 17
Omada Campus Stackable L3 Managed Switch
Figure 2-6
Installation des supports sur le commutateur
4. After the brackets are attached to the device, hold the switch with attached brackets up until it aligns with the brackets on the racks, and gently push the switch backwards until it is in place, then secure the device on the racks with M6 screws and fix brackets B/C or E to brackets D or F with M4 screws on both sides.
Figure 2-7
Installation du commutateur sur des racks
Caution: Leave 5 to 10 cm gaps around the devices for air circulation. Avoid placing heavy things on the device. Mount devices in the order demonstrated above and ensure a certain clearance between devices for
the purpose of heat dissipation.
18 Installation
Omada Campus Stackable L3 Managed Switch
Installation du module d'alimentation
S6500-24GP4XF is shipped with a PSM500-AC power supply module installed, S6500-48GP6XF/ S6500-24MPP4Y/S6500-48MPP6Y is shipped with a PSM900-AC power supply module installed, and S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S750032C is shipped with a PSM550-AC power supply module installed. It looks like below, and the image may differ from your actual product.
Figure 2-8
Apparence du module d'alimentation
Connecteur du cordon d'alimentation CA
FAN
Clips de retenue
Poignée d'extraction
DIRIGÉ
Locking Strap Slot Release Handle
Si vous devez ajouter un module d'alimentation supplémentaire, veuillez suivre les étapes :
1. Portez un bracelet antistatique et assurez-vous qu'il est bien en contact avec la peau et qu'il est bien mis à la terre.
2. Appuyez d'une main sur la poignée d'extraction du module et maintenez le bas du module de l'autre main. Poussez doucement le module le long du rail de guidage du logement.
3. Relâchez la poignée d'extraction pour fixer le module d'alimentation en place.
Figure 2-9
Installation du module d'alimentation
Poignée de libération
Caution: Do not plug the power cord until the power supply module installation is completed. When installing a power supply module, make sure it is set correctly in the operation of installation. Do not use too much force in the installation. If resistance is encountered or positions of the power
supply module appear larger during installation, you must first remove the module and then reinstall the module. If the Retainer Clips cannot spring up naturally and the power module is blocked, it may be due to the power supply module is not installed properly. Please check carefully.
The power supply module is designed with a locking strap slot. If you need to secure the power cable with the included locking strap, please follow the steps:
1. Portez un bracelet antistatique et assurez-vous qu'il est bien en contact avec la peau et qu'il est bien mis à la terre.
Installation 19
Omada Campus Stackable L3 Managed Switch
2. Remove the instruction label on the AC power cable locking strap slot. 3. Attach the clamp to the AC power cable and insert the locking strap into the slot. 4. Adjust tightness and distance of the locking strap using clips to ensure the cable is securely fastened.
Figure 2-10 Installing the Locking Strap
Si vous devez retirer le module d'alimentation, veuillez suivre les étapes :
1. Portez un bracelet antistatique et assurez-vous qu'il est bien en contact avec la peau et qu'il est bien mis à la terre.
2. Depress the retainer clip to release the locking strap, and then remove the power cord from the external power supply system and the power module.
3. Press the extraction handle of the module with one hand, and pull the extraction handle using your other hand, until the module completely comes out of the chassis.
Caution: Unplug the power cord first, then remove the power supply module. When removing a power supply module, make sure that the power supply module is set correctly in the
operation of installation. In order to better protect the power supply module during removal, it is recommended that you
package it in an antistatic bag.
Installation du module de ventilation
S6500-24GP4XF/S6500-48GP6XF/S6500-24M4Y/S6500-24MPP4Y/S6500-48M6Y/S650048MPP6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S7500-32C is shipped with hot-swappable fan modules installed. They look like below, and the images may differ from your actual product.
Figure 2-11 Apparence du module de ventilateur
DIRIGÉ
20 Installation
Extraction Handle Retainer Clips Release Handle
Omada Campus Stackable L3 Managed Switch For normal operation of the switch, please ensure that models with 5 fan modules maintain at least 4 operational modules, while models with 4 fan modules maintain at least 3 operational modules. If one fan module is damaged, please replace it as follows: 1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well
fondé. 2. Appuyez sur la poignée d'extraction du module d'une main et tirez la poignée d'extraction jusqu'à ce que le
Le module sort complètement du châssis.
Figure 2-12 Retrait d'un module de ventilateur endommagé
3. Appuyez d'une main sur la poignée d'extraction d'un nouveau module de ventilateur et maintenez le bas du module de l'autre main. Poussez doucement le module le long du rail de guidage du logement.
4. Release the extraction handle to fix the power supply module in place. Caution: S6500-24GP4XF/S6500-48GP6XF/S6500-24M4Y/S6500-24MPP4Y/S6500-48M6Y/S6500-48MPP6Y/ S7500-26XF6Y uses hot-swappable fan modules with a maximum speed of 9,000 RPM. S7500-48XF4C/ S7500-24Y4C/S7500-48Y8C/S7500-32C uses hot-swappable fan modules with a maximum speed of 18,000 RPM. Please do not interchange or mix fan modules between models. Sharp edges on the fan module may cause injury, so please operate with caution. Make sure the damaged fan module is in place before you are going to replace it. DO NOT unplug the damaged fan module until the replacement operation. Do not use too much force in the replacement. If resistance is encountered or positions of the fan module appear larger during installation, you must first remove the module and then reinstall the module. If the Retainer Clips cannot spring up naturally and the power module is blocked, it may be due to the fan module is not installed properly. Please check carefully.
Installation 21
Omada Campus Stackable L3 Managed Switch
Chapitre 3 Connexion
3.1 port Ethernet
Connectez un port Ethernet du commutateur à l'ordinateur à l'aide d'un câble RJ45 comme le montre la figure suivante.
Figure 3-1
Connexion du port RJ45
Port RJ45
RJ45 câble
3.2 10G SFP+/25G SFP28/100G QSFP28 Slot
The following figure demonstrates the connection of 10G SFP+/25G SFP28/100G QSFP28 slot to an optical module
Figure 3-2
Inserting the Fiber Module
Slot Fiber Module
3.3 port de console
CLI (Command Line Interface) vous permet de gérer le commutateur, vous pouvez donc charger la CLI après avoir connecté les PC ou les terminaux au port de console du commutateur via un câble (un câble de console RJ45 est fourni, tandis que le câble de type C n'est pas fourni)
Connectez le port de console RJ45 de l'appareil à votre ordinateur à l'aide du câble de console, comme le montre la figure suivante.
22 Connexion
Figure 3-3
Connexion du port de console (RJ45)
Omada Campus Stackable L3 Managed Switch
Connectez le port console Type-C de l'appareil à votre ordinateur à l'aide du câble Type-C (non fourni), comme le montre la figure suivante.
Figure 3-4
Connexion du port de console (USB)
Note: RJ45 console port and Type-C console port cannot be used concurrently. Type-C Console port takes
priority over the RJ45 console port. The Type-C console port is hot-pluggable while the RJ45 console port is not. Keep the device power
off when plugging the console cable into the RJ45 console port. Do not connect the console port with other ports by RJ45 cable.
3.4 Vérifier l'installation
Une fois l'installation terminée, vérifiez les éléments suivants : Il doit y avoir un espace libre de 5 à 10 cm autour de l'appareil pour la ventilation et assurez-vous que la circulation de l'air
est adéquat. Le voltage de l'alimentation électrique répond aux exigences du volume d'entréetage de l'appareil. La prise de courant, l'appareil et le rack sont bien mis à la terre. L'appareil est correctement connecté aux autres périphériques réseau.
Connexion 23
Omada Campus Stackable L3 Managed Switch
3.5 Mise sous tension
Branchez le connecteur femelle du cordon d'alimentation fourni dans la prise de courant de l'appareil et branchez le connecteur positif dans une prise de courant comme le montre la figure suivante. Assurez-vous que le voltage de l'alimentation électrique répond aux exigences du volume d'entréetage (100-240 V~ 50/60 Hz).
Figure 3-5
Connexion à l'alimentation électrique
Note: The figure is to illustrate the application and principle. The provided plug and module in your region
may differ from the figures above. Generally PWR1 takes priority over PWR2.
3.6 Initialisation
Une fois l'appareil mis sous tension, il commence l'autotest de mise sous tension. Une série de tests s'exécute automatiquement pour s'assurer que l'appareil fonctionne correctement. Pendant ce temps, ses indicateurs LED répondront dans l'ordre suivant :
1. L'indicateur LED PWR s'allume en permanence. La LED SYS et les indicateurs LED de tous les ports restent éteints.
2. Après environ une minute, la LED SYS et les indicateurs LED de tous les ports clignoteront momentanément puis s'éteindront.
3. Quelques secondes plus tard, l'indicateur LED SYS clignote, ce qui représente une initialisation réussie.
3.7 Topologie de la pile
With stackable design, the switches can be stacked into one stack topology for higher reliability, larger bandwidth, and simpler networking. To build the stack topology, you need to prepare 2-12 switches and enough 10G SFP+/25G SFP28/100G QSFP28 modules/cables. For more details, see the table below:
Changer
Modèle(s) compatible(s)
Quantité
S6500-24G4XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-48G6XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-24GP4XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-48GP6XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-24M4Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y S6500-24MPP4Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y
2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode)
24 Connexion
Omada Campus Stackable L3 Managed Switch
S6500-48M6Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y
S6500-48MPP6Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y
S7500-26XF6Y S7500-26XF6Y
S7500-48XF4C S7500-48XF4C
S7500-24Y4C S7500-24Y4C
S7500-48Y8C S7500-48Y8C
S7500-32C
S7500-32C
2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode)
Il existe trois structures de topologie de pile pour différents scénarios. Veuillez créer la topologie appropriée en fonction de vos besoins :
1. Topologie en chaîne : La topologie en chaîne est relativement simple et ne nécessite pas de connexion par câble entre la première et la dernière unité. Il convient à l’empilage sur de longues distances, mais sa fiabilité est relativement faible.
Figure 3-6
Topologie en chaîne
Groupe de ports d'empilement 2
Groupe de ports d'empilement 1
…
2. Topologie en anneau : la topologie en anneau a une fiabilité plus élevée que la topologie en chaîne. Lorsqu'une des chaînes de la topologie en anneau est déconnectée, la topologie en anneau devient une topologie en chaîne, mais l'ensemble du système de pile peut toujours fonctionner normalement. La topologie en anneau nécessite une connexion par câble entre la première et la dernière unité, elle n'est donc pas adaptée à un empilage sur de longues distances.
Figure 3-7
Topologie de l'anneau
Groupe de ports d'empilement 2
Groupe de ports d'empilement 1
…
Connexion 25
Omada Campus Stackable L3 Managed Switch
3. Topologie en étoile : la topologie en étoile connecte les commutateurs à un commutateur principal central, par conséquent, elle peut augmenter considérablement le taux de transfert de données entre les commutateurs membres tout en offrant une gestion unifiée.
Figure 3-8
Topologie en étoile
Groupe de ports d'empilement 2
Groupe de ports d'empilement 3
Groupe de ports d'empilement 1
…
Note: The stacking port is not allowed to connect to non-stacking port, as it may affect the operation of the
device. Stacking ports with the same group ID are not allowed to connect to stacking ports with different
group IDs, neither to different devices. A stacking port group is a logical port dedicated to stacking and needs to be bound to a stacking port.
A stacking port group can be bound to one or more stacking ports to improve bandwidth and reliability.
26 Connexion
Omada Campus Stackable L3 Managed Switch
Chapitre 4 Configuration
4.1 Configuration terminéeview
Le commutateur prend en charge deux options de configuration :
Mode autonome : configurez et gérez le commutateur individuellement. Mode contrôleur : configurez et gérez les périphériques réseau de manière centralisée. Il est recommandé dans le
réseau à grande échelle, composé de dispositifs de masse tels que des points d'accès, des commutateurs et des passerelles.
Remarque : lorsque le commutateur passe du mode autonome au mode contrôleur, les configurations du commutateur seront perdues. Pour plus de détails, reportez-vous aux documents connexes sur le centre de téléchargement de notre site officiel website : https://support.omadanetworks.com/product/.
4.2 Mode autonome
En mode autonome, utilisez un ordinateur pour configurer et gérer le commutateur à l'aide de l'interface graphique (interface utilisateur graphique) ou de la CLI (interface de ligne de commande).
Figure 4-1
Topologie pour le mode autonome
Changer
PC
Utilisation de l'interface graphique
1. Pour accéder à la page de gestion du commutateur, assurez-vous que le commutateur et l'ordinateur se trouvent dans le même sous-réseau. Ouvrez un navigateur et saisissez l'adresse IP du commutateur dans le champ d'adresse, puis appuyez sur la touche Entrée.
Si le commutateur obtient l'adresse IP du serveur DHCP (généralement une passerelle), recherchez l'adresse IP du commutateur sur le serveur DHCP.
Sinon, utilisez l'adresse IP par défaut 192.168.0.1 pour lancer la page de gestion du commutateur.
2. Lors de votre première connexion, définissez un nom d'utilisateur et un mot de passe pour mieux protéger votre réseau et vos appareils. Le système vous redirigera ensuite automatiquement vers l'interface de connexion pour vous authentifier avec vos nouveaux identifiants.
3. Après une connexion réussie, la page principale apparaîtra. Vous pouvez cliquer sur les menus en haut et à gauche pour configurer les fonctions correspondantes.
Pour les configurations détaillées, reportez-vous au Guide de l'utilisateur et au Guide CLI. Les guides peuvent être trouvés sur le centre de téléchargement de notre site officiel website : https://support.omadanetworks.com/product/.
Utilisation de la CLI Configurez une connexion Telnet ou SSH pour accéder au commutateur via la CLI.
Configuration 27
Omada Campus Stackable L3 Managed Switch
Utilisez le port console pour accéder au commutateur. Lorsque vous utilisez le port console, démarrez le programme d'émulation de terminal (tel que Hyper Terminal) sur le PC et configurez le programme d'émulation de terminal comme suit :
Débit en bauds 38400 XNUMX bps
Bits de données 8
Parité Aucune
Bits d'arrêt 1
Contrôle de flux Aucun
Pour les configurations détaillées, reportez-vous au Guide de l'utilisateur et au Guide CLI. Les guides peuvent être trouvés sur le centre de téléchargement de notre site officiel website : https://support.omadanetworks.com/product/.
Note: You may need to change the password the first time you log in, which will better protect your network and devices.
4.3 Mode contrôleur
Controller Mode applies to the large scale network with mass devices. All devices can be centrally configured and monitored via Omada Pro Hardware Controller (C5300), Omada Pro Software Controller, or Omada Pro Cloud-Based Controller.
Note: Before the following configurations, make sure the switch can access the internet. When using Omada Pro Hardware/Software/Cloud-based Controller, make sure the switch and the controller are in the same subnet. Typically, the switch obtains IP address from the DHCP server. You can check the switch’s IP address on the DHCP server.
Via Omada Pro Hardware Controller (C5300)
Omada Pro Hardware Controller (C5300) is a good alternative if you have no spare PC to keep running Omada Pro Software Controller in the network. It needs to be purchased additionally. Follow the steps below to configure the Omada Pro Hardware Controller (C5300).
Figure 4-2
Manage the network via Omada Pro Hardware Controller (C5300)
Commutateur de passerelle
Omada Pro Hardware Controller (C5300) EAP
28 Configuration
PAE
PAE
Clients
Omada Campus Stackable L3 Managed Switch
Note: Before you start, be sure to power up and connect your devices according to the topology figure. A DHCP server (typically a gateway with DHCP function enabled) is required to assign IP addresses to
the EAPs and clients in your local network. Omada Pro Controller must have network access to some Omada campus devices (the gateway,
switch, or APs) in order to find, adopt, and manage them.
1. Trouvez l'adresse IP de la passerelle. Ouvrez l'invite de commande sur votre PC et saisissez ipconfig. Dans la liste des résultats, recherchez la passerelle par défaut, qui correspond également à l'adresse IP de la passerelle.
2. Lancez un web navigateur et saisissez l'adresse IP de la passerelle. Connectez-vous à la passerelle web page. Allez ensuite dans Réseau > LAN > Liste des clients DHCP pour trouver l'adresse IP de votre contrôleur en fonction de son adresse MAC.
3. Saisissez l'adresse IP de votre contrôleur dans la barre d'adresse pour ouvrir son web page.
4. Sur le contrôleur Omada Pro web page, suivez l'assistant pour terminer la configuration rapide.
5. Après la configuration rapide, la page de connexion apparaît. Saisissez le nom d'utilisateur et le mot de passe que vous avez créés et cliquez sur Connexion. Vous pouvez ensuite configurer davantage le contrôleur.
6. Si vous souhaitez gérer les appareils à distance, suivez les étapes suivantes :
a. Assurez-vous que l'accès au cloud est activé sur votre contrôleur. Par défaut, l'accès au cloud est activé. Assurez-vous que le voyant Cloud clignote lentement.
b. Lancer un web navigateur et entrez https://omada.tplinkcloud.com dans la barre d'adresse. Entrez votre identifiant TP-Link et votre mot de passe pour vous connecter. Cliquez sur + Ajouter un contrôleur et choisissez Contrôleur matériel pour ajouter votre contrôleur. Ensuite, vous pouvez configurer davantage le contrôleur.
For more details, refer to the Installation Guide of C5300.
Via le contrôleur logiciel Omada Pro
Download the Omada Pro Software Controller on a PC with Windows OS or Linux OS. Then run the file and follow the wizard to install the Omada Pro Software Controller. Follow the steps below to configure the Controller.
Figure 4-3
Gérer le réseau via Omada Pro Software Controller
Porte
Changer
Contrôleur
Contrôleur logiciel Omada Pro AP
AP
AP
s'exécutant sur le PC hôte
Clients
Configuration 29
Omada Campus Stackable L3 Managed Switch
1. Launch the Omada Pro Software Controller on your PC. After the initiation process, the controller automatically opens its web page. Sinon, cliquez sur Lancer un navigateur pour gérer le réseau.
2. Sur le contrôleur Omada Pro web page, suivez l'assistant pour terminer la configuration rapide.
3. Après la configuration rapide, la page de connexion apparaît. Saisissez le nom d'utilisateur et le mot de passe que vous avez créés et cliquez sur Connexion. Vous pouvez ensuite configurer davantage le contrôleur.
4. Si vous souhaitez gérer les appareils à distance, suivez les étapes suivantes :
a. Make sure that Cloud Access is enabled on your controller and your controller has been bound with your TP-Link ID. On the Omada Pro Controller’s web Sur la page, accédez à Paramètres > Accès au cloud pour activer l'accès au cloud et lier votre identifiant TP-Link. Si vous l'avez configuré lors de la configuration rapide, ignorez cette étape.
b. Lancer un web navigateur et entrez https://omada.tplinkcloud.com dans la barre d'adresse. Entrez votre identifiant TP-Link et votre mot de passe pour vous connecter. Une liste des contrôleurs qui ont été liés à votre identifiant TP-Link apparaîtra. Ensuite, vous pouvez cliquer sur Lancer pour configurer davantage le contrôleur.
Note: To manage your devices, Omada Pro Software Controller needs to keep running on your computer.
Via le contrôleur basé sur le cloud Omada Pro
Omada Pro Cloud-Based Controller est une bonne alternative sans qu'il soit nécessaire d'installer le contrôleur logiciel sur un PC.
Les licences doivent être achetées en plus.
Figure 4-4
Gérer le réseau via le contrôleur basé sur le cloud Omada Pro
Nuage d'Omada
Porte
Changer
AP
AP
AP
AP
Clients
1. Contact the sales staff to grant the Omada Pro Cloud-Based Controller permission. 2. Launch a web et saisissez https://omada.tplinkcloud.com dans la barre d'adresse. Connectez-vous avec
your TP-Link ID.
30 Configuration
Omada Campus Stackable L3 Managed Switch 3. Click + Add Controller and choose Cloud-Based Controller to add an Omada Pro Controller. Then
Vous pouvez lancer le contrôleur pour adopter et gérer des appareils. * Application Omada : avec l'application Omada, vous pouvez également gérer votre contrôleur, localement ou à distance, depuis votre appareil mobile. Pour les configurations détaillées, consultez le guide d'utilisation du contrôleur. Ce guide est disponible sur le centre de téléchargement de notre site officiel. website : https://support.omadanetworks.com/product/.
Configuration 31
Omada Campus Stackable L3 Managed Switch
Annexe A Dépannage
Q1. Que puis-je faire si j'oublie le nom d'utilisateur et le mot de passe du commutateur ?
1. Connectez le port console du PC au port console du commutateur et ouvrez un programme d'émulation de terminal.
2. Éteignez et redémarrez le commutateur. Effectuez l'action indiquée par le programme d'émulation de terminal pour accéder au menu bootUtil. L'action diffère d'un produit à l'autre. Les actions possibles sont répertoriées ci-dessous : · Appuyez sur n'importe quelle touche pour arrêter le démarrage automatique. · Appuyez sur CTRL-B pour accéder au menu bootUtil.
3. Le menu bootUtil s'affiche. Saisissez le chiffre 6 pour sélectionner l'option « Récupération du mot de passe » et saisissez Y pour supprimer tous les utilisateurs et mots de passe. Vous pourrez ensuite réinitialiser le nom d'utilisateur et le mot de passe.
Q2. Pourquoi le voyant d'alimentation (PWR) fonctionne-t-il anormalement ? Le voyant d'alimentation (PWR/Power) devrait être allumé lorsque le système d'alimentation fonctionne normalement. Si le voyant d'alimentation (PWR/Power) fonctionne anormalement, procédez comme suit :
1. Assurez-vous que le câble d'alimentation est correctement connecté et que le contact d'alimentation est normal. 2. Assurez-vous que le volumetage de l'alimentation électrique répond aux exigences du volume d'entréetage de la
changer.
Q3. Que dois-je faire si je ne peux pas accéder au web page de gestion ? Essayez ce qui suit :
1. Vérifiez chaque voyant de port du commutateur et assurez-vous que le câble Ethernet est correctement connecté. 2. Essayez un autre port du commutateur et assurez-vous que le câble Ethernet est adapté et fonctionne normalement. 3. Éteignez l'interrupteur et, après un certain temps, rallumez-le. 4. Assurez-vous que l'adresse IP de votre PC est définie dans le sous-réseau du commutateur. 5. Si vous ne parvenez toujours pas à accéder à la page de configuration, réinitialisez le commutateur à ses paramètres d'usine par défaut. Alors
l'adresse IP de votre PC doit être définie sur 192.168.0.x (« x » est n'importe quel nombre compris entre 2 et 254) et le masque de sous-réseau sur 255.255.255.0.
Q4. Pourquoi le programme d'émulation de terminal ne s'affiche-t-il pas correctement ? Essayez la solution suivante :
1. Assurez-vous que l'alimentation électrique est normale et que le câble de la console est correctement connecté. 2. Vérifiez si le câble de la console est du bon type. 3. Assurez-vous que les paramètres du programme d'émulation de terminal sont corrects : configurez Bits par seconde
comme 38400, les bits de données comme 8, la parité comme Aucune, les bits d'arrêt comme 1 et le contrôle de flux comme Aucun.
32 Annexe A Dépannage
Omada Campus Stackable L3 Managed Switch
Annexe B Spécifications
Specifications for S6500 Series Switches
Article
Contenu
IEEE 802.3, IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z, IEEE 802.3ae, IEEE 802.3x
Normes
IEEE 802.3af/at (For S6500-24GP4XF, S6500-48GP6XF) IEEE 802.3af/at/bt (For S6500-24MPP4Y, S6500-48MPP6Y)
IEEE 802.3bz, IEEE 802.3by, IEEE 802.3cc (For S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y)
10BASE-T: 2-pair UTP/STP of Cat. 3,4,5 (maximum 100 m) 100BASE-TX: 2-pair UTP/STP of Cat. 5 or above (maximum 100 m) 1000BASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m) 2.5GBASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m) Transmission Medium 1000BASE-SX/LX/LX10/BX10: MMF, SMF 10GBASE-SR/LR: MMF, SMF 10G SFP+ Direct Attach Cable (SM5220-1M, SM5220-3M) 25GBASE-SR/LR: MMF, SMF (SM6110-SR, SM6110-LR) 25G SFP28 Direct Attach Cable (SM6220-1M)
S6500-24G4XF/S6500-24M4Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, Port 1-24, Port 25-28 S6500-24GP4XF/S6500-24MPP4Y: PWR1, PWR2, SYS, FAN, PoE Max, MGMT, MST, SPEED, STK, PoE, Port 1-24, Port 25-28 LED S6500-48G6XF/S6500-48M6Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, Port 1-48, Port 49-54 S6500-48GP6XF/S6500-48MPP6Y: PWR1, PWR2, SYS, FAN, PoE Max, MGMT, MST, SPEED, STK, PoE, Port 1-48, Port 49-54
Annexe B Spécifications 33
Omada Campus Stackable L3 Managed Switch
Budget PoE
For S6500-24GP4XF: 402W (with 1*PSM500-AC, by default) 720W (with 1*PSM900-AC) 720W (with 2*PSM500-AC) 720W (with 1*PSM500-AC and 1*PSM900-AC) 720W (with 2*PSM900-AC) For S6500-48GP6XF: 764W (with 1*PSM900-AC, by default) 384W (with 1*PSM500-AC) 812W (with 2*PSM500-AC) 1176W (with 1*PSM500-AC and 1*PSM900-AC) 1440W (with 2*PSM900-AC) For S6500-24MPP4Y: 751W (with 1*PSM900-AC, by default) 378W (with 1*PSM500-AC) 802W (with 2*PSM500-AC) 1168W (with 1*PSM500-AC and 1*PSM900-AC) 1534W (with 2*PSM900-AC) For S6500-48MPP6Y: 701W (with 1*PSM900-AC, by default) 328W (with 1*PSM500-AC) 752W (with 2*PSM500-AC) 1118W (with 1*PSM500-AC and 1*PSM900-AC) 1484W (with 2*PSM900-AC)
Température et altitude de fonctionnement
For S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y: -5 °C to 50 °C (23 °F to 122 °F) @ 300 meters -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters For S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y: -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters
Température de stockage -40 °C à 70 °C (-40 °F à 158 °F)
Humidité de fonctionnement 10 % à 90 % HR sans condensation
Humidité de stockage
5% à 90% HR sans condensation
34 Annexe B Spécifications
Omada Campus Stackable L3 Managed Switch
Specifications for S7500 Series Switches
Article
Contenu
Normes
IEEE 802.3, IEEE 802.3x IEEE 802.3z, IEEE 802.3ae (For S7500-26XF6Y, S7500-48XF4C, S7500-24Y4C, S7500-48Y8C IEEE 802.3by, IEEE 802.3cc (For S7500-26XF6Y, S7500-24Y4C, S7500-48Y8C) IEEE 802.3 ba, IEEE 802.3bm (For S7500-48XF4C , S7500-24Y4C, S7500-48Y8C, S7500-32C)
1000BASE-SX/LX/LX10/BX10: MMF, SMF 10GBASE-SR/LR: MMF, SMF 10G SFP+ Direct Attach Cable (SM5220-1M, SM5220-3M) 25GBASE-SR/LR: MMF, SMF (SM6110-SR, SM6110-LR) 25G SFP28 Direct Attach Cable (SM6220-1M) 40GBASE-SR4/LR4: MMF, SMF (For S7500-48XF4C, S7500-24Y4C, Transmission Medium S7500-48Y8C, S7500-32C) 40G QSFP+ Direct Attach Cable (For S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C) 100GBASE-SR4/LR4: MMF, SMF (SM9110-SR4 for S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C) 100G QSFP28 Direct Attach Cable (SM9220-1M for S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C)
DIRIGÉ
Température et altitude de fonctionnement
S7500-26XF6Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPD, STK, SFP+, SFP28 S7500-48XF4C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, SFP+, QSFP28 S7500-24Y4C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPD, STK, SFP28, QSFP28 S7500-48Y8C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, SFP28, QSFP28 S7500-32C: PWR1, PWR2, SYS, MGMT, FAN, MST, SPEED, STK, QSFP28 -5 °C to 45 °C (23 °F to 113 °F) @ 300 meters -5 °C to 40 °C (23 °F to 104 °F) @ 2,000 meters -5 °C to 35 °C (23 °F to 95 °F) @ 3,000 meters
Température de stockage -40 °C à 70 °C (-40 °F à 158 °F)
Humidité de fonctionnement 10 % à 90 % HR sans condensation
Humidité de stockage
5% à 90% HR sans condensation
For S7500-26XF6Y, S7500-48XF4C, and S7500-24Y4C, the maximum operating temperature supported can reach 50 °C (122 °F) @ 300 meters, 45 °C (113 °F) @ 2,000 meters, and 40 °C (104 °F) @ 3,000 meters.
L'altitude supportée est du niveau de la mer jusqu'à 5000 m. Il convient de noter que lorsque l'altitude est supérieure à 2000 220 m, pour chaque 1 mètres d'augmentation d'altitude, la température maximale de fonctionnement baissera de 1.8°C (XNUMX°F).
Annexe B Spécifications 35
Omada Campus Stackable L3 Managed Switch
Spécifications des modules d'alimentation
PSM500-AC
(For S6500-24GP4XF/ S6500-48GP6XF/ S6500-24MPP4Y/ S6500-48MPP6Y)
PSM900-AC
(For S6500-24GP4XF/ S6500-48GP6XF/ S6500-24MPP4Y/ S6500-48MPP6Y)
PSM550-AC
(For S6500-24M4Y/ S6500-48M6Y/ S7500-26XF6Y/ S7500-48XF4C/ S7500-24Y4C/ S7500-48Y8C/ S7500-32C)
Puissance d'entrée
100 V240 V~ 50/60 Hz 8A
100-120 V (inclus) ~ 50/60 Hz 12 A (pour les emplacements utilisant un faible volumetage, voir les spécifications pour les pays/régions spécifiques)
120 (non inclus)240V~ 50/60Hz 10A (pour autres emplacements)
100 V240 V~ 50/60 Hz 7A
Volume de sortietage
Primaire : 53.5 VCC Veille : 12 VCC
Primaire : 53.5 VCC Veille : 12 VCC
Primaire : 12 VCC Veille : 12 VCC
Courant de sortie
9.35 A (maximum)
16.5 A (maximum)
45 A (maximum)
Puissance de sortie
500 W (maximum)
900 W (maximum)
550 W (maximum)
Altitude de fonctionnement
Pour PSM500-AC/PSM900-AC : niveau de la mer jusqu'à 3000 550 m Pour PSM5000-AC : niveau de la mer jusqu'à XNUMX XNUMX m
36 Annexe B Spécifications
Avertissement concernant le marquage CE
Il s'agit d'un produit de classe A. Dans un environnement domestique, ce produit peut provoquer des interférences radioélectriques, auquel cas l'utilisateur peut être amené à prendre des mesures adéquates.
Déclaration de conformité UE
TP-Link déclare par la présente que le commutateur est conforme aux exigences essentielles et aux autres dispositions pertinentes des directives 2014/30/UE, 2014/35/UE, 2011/65/UE et (UE) 2015/863. La déclaration de conformité UE originale est disponible à l'adresse https://www.tp-link.com/en/support/ce/
Déclaration de conformité du Royaume-Uni
TP-Link déclare par la présente que le commutateur est conforme aux exigences essentielles et aux autres dispositions pertinentes du Règlement de 2016 sur la compatibilité électromagnétique et du Règlement de 2016 sur les équipements électriques (sécurité). La déclaration de conformité originale du Royaume-Uni est disponible à l'adresse https://www.tp-link.com/support/ukca/
, .
PRUDENCE:
Fusible bipolaire et neutre. Débranchez le secteur avant l'entretien.
Consignes de sécurité
· Gardez l'appareil à l'écart de l'eau, du feu, de l'humidité ou des environnements chauds. · N'essayez pas de démonter, réparer ou modifier l'appareil. Si vous avez besoin d'un service, veuillez nous contacter. · Placez l'appareil avec sa surface inférieure vers le bas. · La fiche du cordon d'alimentation est utilisée comme dispositif de déconnexion, la prise de courant doit être
facile d'accès. · Branchez le produit sur les prises murales avec connexion à la terre via le cordon d'alimentation
or plug. · The socket-outlet shall be installed near the equipment and shall be easily accessible. · The PoE ports shall not be used to charge lithium batteries or devices supplied by lithium
piles.
· Operating temperature: For S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/ S7500-48XF4C/S7500-24Y4C: -5 °C to 50 °C (23 °F to 122 °F) @ 300 meters -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters For S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y: -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters S7500-48Y8C/S7500-32C: -5 °C to 45 °C (23 °F to 113 °F) @ 300 meters -5 °C to 40 °C (23 °F to 104 °F) @ 2,000 meters -5 °C to 35 °C (23 °F to 95 °F) @ 3,000 meters
· : S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/ S7500-24Y4C -5°C 50°C23°F 122°F@ 300 -5°C 45°C23°F 113°F@ 2,000 -5°C 40°C23°F 104°F@ 3,000 S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y -5°C 45°C23°F 113°F@ 2,000 -5°C 40°C23°F 104°F@ 3,000 S7500-48Y8C/S7500-32C -5°C 45°C23°F 113°F@ 300 -5°C 40°C23°F 104°F@ 2,000 -5°C 35°C23°F 95°F@ 3,000
This equipment is not suitable for use in locations
where children are likely to be present.
Veuillez lire et respecter les consignes de sécurité ci-dessus lors de l'utilisation de l'appareil. Nous ne pouvons garantir qu'aucun accident ou dommage ne surviendra en raison d'une utilisation incorrecte de l'appareil. Veuillez utiliser ce produit avec précaution et l'utiliser à vos propres risques.
Pour obtenir une assistance technique, des guides d'utilisation et d'autres informations, veuillez visiter https://support.omadanetworks.com/ ou scannez simplement le code QR.
© 2026 TP-Link 7100002759 RÉV2.0.1