Contenu
cacher
LTECH KBS Switch Module

Diagramme du système

Présentation du produit
- Bluetooth 5.2 SIG Mesh communication protocol, offering strong networking capabilities, reliability, and stability.
- Equipped with dual-relay functionality, enabling control of two sets of lighting devices.
- Supports both mechanical and push switches. Even if the light is manually turned off, remote control via the APP remains available, meeting diverse needs.
- Supports OTA (Over-the-Air) online upgrades, ensuring timely feature updates and usage safety, keeping the product up-to-date.
- Supports direct connection to devices via smartphone, allowing direct control through the APP. Supports gateway-free control, enabling LAN remote control, wireless panels, group control, and more. Supports integration with a smart gateway to enable remote control of home devices, making life more convenient.
- Compact size, allowing easy installation in European, American, and national standard junction boxes, suitable for various installation scenarios.
- Supports power-off reset functionality and mechanical key reset functionality.
Spécifications techniques
| Modèle | KBS |
| Type sans fil | Maillage SIG Bluetooth 5.2 |
| Changer de chaîne | 2CH |
| Vol. de fonctionnementtage | 100-240V~, 50/60Hz, |
| Max. load current of the relay | 10A |
| Max. load parameters of the relay | Resistive load: 1000W@230Vac/CH, 500W@110Vac/CH, Max.2000W Capacitive load: 400W@230Vac/CH, 200W@110Vac/CH, Max.800W |
| Courant de surtension du relais | 70 A à 10 ms |
| Température de fonctionnement | -25°C~50°C |
| Taille du produit | L45 × l45.5 × H20.5 (mm) |
| Poids du produit | 30g |
| Normes | UL 8750、EN 61347-2-13:2014+A1:2017、EN 61347-1:2015+A1:2021、EN 62493:2015/A1:2022 |
Images du produit

Taille du produit

Schéma de câblage
- Two mechanical switches control one relay each.
- One mechanical switch controls two relays.

- Two push switches control one relay each.
- One push switch controls two relays.

Applications recommandées
- commande d'éclairage sans fil
- After setting up the remote control association with the switch module via the APP, both the APP and the remote control can be used to control the device.

- Supports local scenes, gateway-free operation, and controllable even when offline.
- Work with intelligent gateway, it can realize visual control, cloud scene and automatic linkage.

- Intelligent control. Set up more app configs as you like
Mode d'emploi de l'application
- Créer un compte
Scannez le code QR ci-dessous avec votre téléphone mobile et suivez les instructions pour terminer l'installation de l'application.
- Réglage des paramètres
More settings such as editable binding interface, group control, local scenes, cloud scenes, and automation.
- Binding interface settings
After pairing is completed, enter the binding interface for the smart remote control/smart wireless switch. Select the switch module device to associate it, and then you can control the device’s on/off function using the smart remote control/smart wireless switch. You can also unbind the device from this interface.
- Light fixture group
The same type of lighting fixtures can be grouped together, allowing users to control power on/off and other operations for the entire group, making operations more convenient. Switch to the “Group” menu, click the “+” icon in the upper right corner, follow the prompts to modify the group name, then click “Next,” select the devices you want to include in the group, and save.
- Scène locale
Switch to the 【Smart】 page, click “+” in the upper right corner to create a local scene, and after setting the execution action, you can realize the local linkage of Bluetooth devices.
- Scènes de cloud et automatisation
Make sure that a smart gateway, such as SP-GW-6S,has been added to the family.
Cloud scenes: Switch to the 【Smart】 interface and click “+” to create a cloud scene. After setting the execution action, remote linkage can be achieved.
Automation: Select “Automation” in the【Smart】page and click “+” to create automation. You can choose local/cloud execution mode,and set trigger conditions and execution actions. When the set trigger conditions are met, a series of device actions are automatically triggered to achieve remote linkage
Réinitialiser aux paramètres d'usine
- Mechanical Reset: Connect device to lighting fixture. Hold reset button for 15s until indicator light flashes red rapidly, then release. Press reset button 3 times briefly within 3s. Slow red flash means factory settings restored; rapid blue flash means setup is complete.
- Power Cycle Reset: With power off, switch device on for 15s then off. Repeat power on/off 6 times (2s on, 5s off each). On 7th power-on, connected fixture blinks 3 times, showing factory settings restored.
- APP Reset: Click the ” ” on the switch module to enter the main interface, then click the ” ” in the upper right corner to access the settings interface. Click “Delete Device” to complete the reset.

Attention
- Product installation and commissioning should be done by a qualified professional. Our company products are and not lightning proof non-waterproof(special models excepted). Please avoid the sun and rain. When installed outdoors, please ensure they are mounted in a water proof enclosure or in an area equipped with lightning protection devices Good heat dissipation will prolong the working life of products. Please ensure good ventilation.
- Veuillez vérifier si le volume de travailtage utilisé est conforme aux exigences des paramètres des produits.
- Le diamètre du fil utilisé doit être en mesure de charger les luminaires que vous connectez et d'assurer un câblage ferme.
- Avant d'allumer les produits, assurez-vous que tout le câblage est correct en cas de connexion incorrecte qui endommage les luminaires.
- En cas de panne, n'essayez pas de réparer les produits par vous-même. Si vous avez des questions, veuillez contacter vos fournisseurs.
Accord de garantie
Délais de garantie à compter de la date de livraison : 5 ans.
Des services de réparation ou de remplacement gratuits pour les problèmes de qualité sont fournis pendant les périodes de garantie.
Exclusions de garantie ci-dessous :
Les conditions suivantes ne font pas partie de la garantie des services de réparation ou de remplacement gratuits :
- Au-delà des périodes de garantie.
- Tout dommage artificiel causé par un vol élevétage, surcharge ou opérations incorrectes. Produits avec de graves dommages physiques.
- Dommages causés par des catastrophes naturelles et des cas de force majeure.
- Les étiquettes de garantie et les codes-barres ont été endommagés.
- Aucun contrat n'a été signé par notre société.
- La réparation ou le remplacement constituent le seul recours pour les clients. Notre société décline toute responsabilité pour les dommages indirects ou consécutifs, sauf dans les limites prévues par la loi.
- Notre société se réserve le droit de modifier ou d'ajuster les termes de cette garantie, et toute modification apportée sous forme écrite fera foi.
Ce manuel est sujet à modifications sans préavis. Les fonctions du produit dépendent des marchandises. N'hésitez pas à contacter nos distributeurs officiels si vous avez des questions.