1. Consignes de sécurité
Operating a generator requires adherence to strict safety guidelines to prevent injury or property damage. Always read and understand the entire manual before operating the GENMAX GM12500iET generator.
Sécurité au monoxyde de carbone (CO)
This generator is equipped with a built-in CO sensor for enhanced safety. The CO sensor is designed to shut down the generator if harmful levels of carbon monoxide accumulate in the operating area. However, this feature is a supplement and does not replace safe operating practices.
- Operate Outdoors Only: Always operate the generator outdoors in a well-ventilated area, far away from windows, doors, and vents to prevent carbon monoxide from entering enclosed spaces.
- Direction des gaz d'échappement : Ensure the exhaust is directed away from people and buildings.
- Alarmes CO : Install battery-operated carbon monoxide alarms in your home or RV and check them regularly.
Sécurité du carburant
- Flammable Fuels: Gasoline, propane (LPG), and natural gas (NG) are highly flammable. Handle all fuels with extreme caution.
- Interdiction de fumer: Do not smoke or allow open flames near the generator or fuel storage areas.
- Ravitaillement: Always turn off the generator and allow it to cool before refueling with gasoline.
- Stockage: Store fuels in approved containers in a well-ventilated area, away from ignition sources.
Sécurité électrique
- Conditions sèches : Never operate the generator in wet conditions, rain, or snow. Keep hands dry when handling electrical components.
- Mise à la terre : Assurez-vous que le générateur est correctement mis à la terre conformément aux normes électriques locales.
- Protection contre les surcharges : Do not overload the generator. Utilize the circuit breakers to prevent damage.
- Prises GFCI : The generator features GFCI outlets for protection against electric shock.
2. Produit terminéview
The GENMAX GM12500iET is a powerful and versatile tri-fuel inverter generator designed for various applications, including home backup, RV use, and camping. It offers flexible fueling options, clean power output, and multiple starting methods.

Image: The GENMAX GM12500iET Tri-Fuel Inverter Generator shown with gasoline, propane, and natural gas options, highlighting its versatile fuel technology.
Caractéristiques principales
- Capacité tri-carburant : Operates on Gasoline (12500 surge, 10500 running watts), Propane (LPG 11500 surge, 9500 running watts), and Natural Gas (NG 10000 surge, 8500 running watts).
- Clean Inverter Power: Delivers less than 3% Total Harmonic Distortion (THD), making it safe for sensitive electronics.
- High-Capacity Output: Features a 458cc OHV engine with multiple outlets including 120V/240V 50A (NEMA 14-50R), 120V 30A, 120V 20A, 12V DC, and dual USB ports.
- Smart Digital Control: Digital display shows wattage, voltage, frequency, runtime, fuel level, and alerts.
- 4-Way Start: Electric Start, Bluetooth App, 2-Wire Auto Start, and Recoil Backup.
- Mode éco : Automatically adjusts engine speed to load, reducing noise and extending runtime.
- Conception portable : Equipped with a robust frame, wheels, and a foldable handle for easy transport.
- Caractéristiques de sécurité : Includes a built-in CO sensor and comprehensive protection against overload, over/under voltage, court-circuit et surchauffe.

Image: The GENMAX GM12500iET generator is depicted as suitable for multiple scenarios, including home backup, RV travel, camping, and powering tools at job sites.
3. Installation
Before starting the generator, proper setup is crucial for safe and efficient operation.
3.1 Déballage et inspection
- Retirez soigneusement le générateur et tous ses accessoires de leur emballage.
- Inspect the generator for any signs of shipping damage. If damage is found, contact customer support immediately.
- Verify all included components are present as listed in the 'What Comes in the Box' section.

Image: A visual representation of the items included in the GENMAX GM12500iET package, such as a spark plug wrench, screwdriver, remote control key, funnel, battery charger, NG quick connector, LPG hose, NG hose, and automatic start/stop cable.
3.2 Assemblage de la roue et de la poignée
Attach the wheels and foldable handle using the provided hardware. This design facilitates easy transport of the generator.

Image: A person easily transporting the GENMAX GM12500iET generator across a lawn, demonstrating its easy transport design with a foldable handle and durable wheels.
3.3 Ajouter de l'huile moteur
- Repérez le bouchon de remplissage d'huile/la jauge.
- Assurez-vous que le générateur est placé sur une surface plane.
- Using the provided funnel, slowly add the recommended engine oil (refer to specifications for type and capacity) until it reaches the upper mark on the dipstick. Do not overfill.
- Remettez correctement le bouchon de remplissage d'huile.
3.4 Connectez la batterie
- Localisez le compartiment à piles.
- Raccordez le câble positif (+) de la batterie (rouge) à la borne positive (+) et le câble négatif (-) de la batterie (noir) à la borne négative (-). Assurez-vous que les connexions sont bien serrées.
3.5 Raccordement au carburant
The GM12500iET supports three fuel types: Gasoline, Propane (LPG), and Natural Gas (NG).
- Essence: Fill the fuel tank with fresh, unleaded gasoline. Do not use E85 or mixed fuels.
- Propane (GPL): Connect a standard propane tank to the dedicated LPG inlet using the provided LPG hose. Ensure all connections are tight to prevent leaks.
- Gaz Naturel (GN): Connect to a natural gas supply line using the provided NG hose and quick connector. Ensure connections are secure and leak-free.
Important: Only use one fuel type at a time. Select the desired fuel using the fuel selector switch on the control panel.
Video: A detailed instructional video (22:55) covering the setup and initial preparation of the GENMAX GM12500iET Tri-Fuel Inverter Generator.
4. Mode d'emploi
Follow these steps to safely start and operate your GENMAX GM12500iET generator.
4.1 Panneau de configuration terminéview
Familiarisez-vous avec les composants du panneau de commande avant utilisation.

Image : Un gros plan view of the generator's control panel, showing the digital display, main switch, fuel source switch, LPG/NG inlet, AC breakers, ground terminal, various AC outlets (50A, 30A, 20A), DC 12V outlet, USB ports, and the battery charging port.
4.2 Démarrage du générateur
The GM12500iET offers four starting methods:
- Démarrage électrique :
- Assurez-vous que le générateur est placé sur une surface plane et que toutes les connexions sont bien fixées.
- Select the desired fuel type using the fuel source switch.
- Turn the main switch to the 'ON' position.
- Maintenez le bouton « START/STOP » enfoncé jusqu’à ce que le moteur démarre.
- Bluetooth App Start:
- Download the GENMAX app to your smartphone.
- Pair your device with the generator via Bluetooth.
- Follow the in-app instructions to start the generator remotely.
- 2-Wire Auto Start (for Home Backup):
- Connect the provided 2-wire auto start cable to a compatible automatic transfer switch (ATS) or home backup system.
- Ensure the 'AUTO GEN START SW' is in the 'ON' position.
- The generator will automatically start when power is lost and shut down when utility power returns.

Image: The GENMAX GM12500iET generator is shown providing power to an RV, illustrating the convenience of its Auto Gen Start feature with a communication cable for automatic starting and stopping.
- Recoil Backup Start:
- Ensure the main switch is 'ON' and fuel is selected.
- Tirez fermement et en douceur sur la poignée du lanceur à rappel jusqu'à ce que le moteur démarre.
4.3 Fonctionnement en mode éco
Engage Eco-Mode by pressing the 'ECO' button on the control panel. In Eco-Mode, the engine speed automatically adjusts to the electrical load, which reduces fuel consumption and noise levels, especially during light load conditions. This feature extends runtime and is ideal for quiet environments.

Image: The GENMAX GM12500iET generator operating outdoors, demonstrating its stable sine wave and low-noise technology, with a sound level indicator showing 62 dB at 7 meters.
4.4 Raccordement des charges électriques
- Once the generator is running stably, plug in your electrical devices or connect to your transfer switch.
- Ne pas dépasser la puissance nominale de fonctionnement du générateur.tage. Monitor the digital display for wattage sortie.
- Ensure all connected devices are in good working order and their power requirements are within the generator's capacity.
Video: An instructional video (4:28) demonstrating the operational procedures and features of the GENMAX GM12500iET generator.
5. Entretien
Regular maintenance ensures the longevity and reliable performance of your GENMAX GM12500iET generator.
Huile moteur 5.1
- Vérifier le niveau d'huile : Before each use, check the engine oil level and add if necessary.
- Vidange: Change the engine oil after the first 20 hours of operation, then every 100 hours or annually, whichever comes first. Refer to the specifications for recommended oil type.
5.2 Filtre à air
- Inspection: Inspect the air filter element every 50 hours or monthly.
- Nettoyage/Remplacement : Clean or replace the air filter element as needed, especially in dusty conditions. A dirty air filter can reduce engine performance and increase fuel consumption.
5.3 Bougie d'allumage
- Inspection: Inspectez la bougie d'allumage toutes les 100 heures ou une fois par an.
- Nettoyage/Remplacement : Clean or replace the spark plug if it is fouled or worn. Ensure the gap is set correctly according to the engine specifications.
5.4 Système d'alimentation en carburant
- Filtre à carburant : Inspect and clean or replace the fuel filter as recommended in the full manual.
- Stockage du carburant : For gasoline, use a fuel stabilizer if storing the generator for extended periods. Drain the carburetor if storing for more than 30 days without stabilizer.
5.5 Nettoyage et stockage généraux
- Gardez le générateur propre et exempt de débris.
- Store the generator in a dry, well-ventilated area, away from direct sunlight and extreme temperatures.
- If storing for an extended period, perform all necessary maintenance, including draining fuel (for gasoline) or disconnecting propane/natural gas lines.
6. Dépannage
This section provides solutions to common operational issues. For more complex problems, contact GENMAX technical support.
| Problème | Cause possible | Solution |
|---|---|---|
| Le moteur ne démarre pas |
|
|
| Low power output / Engine stalls under load |
|
|
| Generator runs but no power output |
|
|
| CO sensor shutdown |
|
|
Video: A brief instructional video (3:36) that may cover common troubleshooting steps or specific features of the generator.
7. Spécifications
Detailed technical specifications for the GENMAX GM12500iET Tri-Fuel Inverter Generator.
| Fonctionnalité | Spécification |
|---|---|
| Nom du modèle | GM12500iET |
| Marque | GENMAX |
| Type de moteur | 4 Stroke, OHV |
| Cylindrée du moteur | 458 centimètres cubes |
| Type de carburant | Tri Fuel (Gasoline, Propane, Natural Gas) |
| Gasoline Starting Wattage | 12500 watts |
| Gasoline Running Wattage | 10500 watts |
| Propane (LPG) Starting Wattage | 11500 watts |
| Propane (LPG) Running Wattage | 9500 watts |
| Natural Gas (NG) Starting Wattage | 10000 watts |
| Natural Gas (NG) Running Wattage | 8500 watts |
| Volume du réservoir | 6.1 gallons |
| Distorsion harmonique totale (THD) | ≤3% |
| Niveau sonore (25 % de charge) | Aussi bas que 62 dB(A) |
| Dimensions du produit (L x l x H) | 30.9" x 22.63" x 29.33" |
| Poids de l'article | 251.92 livres |
| Caractéristiques spéciales | CO Sensor, Bluetooth, 2-Wire Auto Start, Eco-Mode |
| Composants inclus | Spark Plug Socket Wrench, Wrench, Remote Control Key, Funnel, Battery Charger, NG Quick Connector, LPG Hose, NG Hose, Automatic Start/Stop Cable |
8. Garantie et assistance
GENMAX is committed to providing reliable products and customer satisfaction.
8.1 Informations sur la garantie
The GENMAX GM12500iET Tri-Fuel Inverter Generator is backed by a Garantie limitée de 3 ansCette garantie couvre les défauts de matériaux et de fabrication dans des conditions normales d'utilisation et d'entretien. Veuillez conserver votre preuve d'achat pour toute réclamation au titre de la garantie.
For specific terms and conditions of the warranty, please refer to the warranty card included with your product or visit the official GENMAX website.
8.2 Assistance technique
Should you encounter any issues or require assistance with your generator, GENMAX offers ongoing technical support. Please have your model number (GM12500iET) and serial number ready when contacting support.
Contact information for technical support can typically be found on the GENMAX website or in the documentation provided with your generator.





