FireAngel FA6812

FireAngel FA6812 Digital LCD Carbon Monoxide Detector User Manual

Modèle: FA6812

1. Introduction

The FireAngel FA6812 is a digital carbon monoxide (CO) detector designed to provide reliable protection against the dangers of CO gas. Carbon monoxide is an invisible, odorless, and potentially fatal gas. This device features an electrochemical sensor with a 10-year lifespan and an LCD screen for clear display of CO levels and device status. Early detection and warning are crucial for preventing CO poisoning.

FireAngel FA6812 Carbon Monoxide Detector on a kitchen counter

Figure 1: FireAngel FA6812 Carbon Monoxide Detector

This manual will guide you through the installation, operation, and maintenance of your FA6812 detector to ensure optimal performance and safety.

2. Configuration et installation

2.1 Contenu du paquet

  • Avertisseur de monoxyde de carbone FireAngel FA6812
  • 2 piles AA
  • Vis de fixation et chevilles
  • Manuel d'utilisation

2.2 Installation de la batterie

The FA6812 detector requires 2 AA batteries for operation. These are included in the package. To install the batteries:

  1. Localisez le compartiment à piles à l’arrière de l’appareil.
  2. Ouvrez le couvercle du compartiment à piles.
  3. Insérez les 2 piles AA en veillant à respecter la polarité (+ et -).
  4. Fermez soigneusement le couvercle du compartiment à piles.

The device will emit a short beep and the LCD will activate, indicating successful battery installation.

2.3 Recommandations de stage

For optimal CO detection, consider the following placement guidelines:

  • General Placement: Install the detector at mid-height in a room, as carbon monoxide mixes evenly with air. Avoid placing it near the floor or ceiling.
  • Proximity to Appliances: Place the detector at least 3 meters (10 feet) away from any fuel-burning appliances (e.g., boilers, gas stoves, fireplaces).
  • Zones de couchage : For maximum protection, install a detector in or near sleeping areas.
  • Évitez les obstacles : Ensure the detector is not obstructed by furniture, curtains, or other objects that could block the sensor.
  • Facteurs environnementaux : Avoid placing the detector in direct sunlight, in areas of high humidity (e.g., bathrooms), or near ventilation openings.

2.4 options de montage

The FA6812 can be used freestanding or wall-mounted.

  • Sur pied: The compact and portable design allows the unit to be placed on a flat surface, such as a shelf or table.
  • Montage mural : Use the integrated mounting bracket and provided screws to securely attach the detector to a wall. Ensure the mounting location adheres to the placement recommendations above.
FireAngel FA6812 Carbon Monoxide Detector with packaging showing 10-year sensor and replaceable AA batteries

Figure 2 : Produit surview avec des fonctionnalités clés

3. Fonctionnement

3.1 LCD Display Indications

The digital LCD screen provides real-time information about the detector's status:

  • Mode veille: Displays the current CO level in parts per million (ppm). If no CO is detected, it will show '0 ppm'.
  • Alarme CO : When dangerous CO levels are detected, the screen will display the CO concentration in ppm, accompanied by an audible alarm and a flashing red light.
  • "AL" (Alarm in Absence): If a CO alarm triggers while you are away, the device will enter "Alarm in Absence" mode. The screen will display "AL", and the unit will beep every 40 seconds with a red flashing light until deactivated.
  • État de la batterie : An icon indicates the battery level. A flashing orange "!" and continuous beep signify low batteries.
  • "EOL" (End of Life): This indicator signals that the device has reached the end of its 10-year operational life and needs replacement.
FireAngel FA6812 LCD screen showing various functions and indicators

Figure 3: Multifunction LCD Screen

3.2 Activation de l'alarme

In the event of CO detection, the FA6812 will:

  • Emit four loud beeps (85 dB(A) at 3m minimum).
  • Flash a red LED light.
  • Display the CO concentration in ppm on the LCD screen.

Si l'alarme retentit :

  1. Sortez immédiatement prendre l'air ou ouvrez toutes les portes et fenêtres.
  2. Effectuez un comptage pour vérifier que toutes les personnes sont présentes.
  3. Ne pénétrez pas de nouveau dans les locaux tant que l'alarme n'a pas cessé et que la zone n'a pas été entièrement aérée.
  4. Consultez un médecin si vous présentez des symptômes d'intoxication au CO (maux de tête, nausées, vertiges).
  5. Contact the appropriate emergency services or a qualified technician to investigate the source of the CO.

3.3 Sleep Easy™ Function

The Sleep Easy™ function allows you to temporarily silence the low battery warning for 8 hours. To activate:

  • Press and hold the test button when the low battery warning sounds.

During this period, the orange indicator light will continue to flash, and the device remains fully functional for CO detection. This feature is designed for convenience, but batteries should be replaced as soon as possible.

FireAngel FA6812 showing advanced functions like 'Alarm in your absence' and 'Sleep Easy'

Figure 4 : Fonctions avancées

4. Entretien

4.1 Tests réguliers

It is recommended to test your CO detector monthly to ensure it is functioning correctly. To perform a test:

  • Press and hold the 'TEST' button on the front of the unit.
  • The alarm will sound, and the red LED will flash, indicating the alarm is working.
  • Relâchez le bouton pour arrêter le test.

4.2 Remplacement de la batterie

When the batteries are low, the detector will indicate this with a flashing orange "!" on the LCD and a continuous beep. Replace the batteries immediately to maintain continuous protection. Refer to section 2.2 for battery installation instructions.

4.3 End of Life (EOL) Indication

The FA6812 has a 10-year lifespan. When the device reaches its end of life, the LCD will display "EOL". At this point, the detector should be replaced with a new unit to ensure continued safety.

4.4 Nettoyage

Dust and debris can affect the detector's performance. Gently clean the exterior of the unit with a soft, damp cloth. Do not use cleaning agents or solvents, as these can damage the sensor or casing. Do not paint the detector.

5. Dépannage

ProblèmeCause possibleSolution
Alarm sounds and LCD shows CO levelMonoxyde de carbone détectéFollow alarm activation procedures (Section 3.2). Evacuate, ventilate, seek medical help if needed, and identify CO source.
Flashing orange "!" and continuous beepAvertissement de batterie faibleReplace batteries immediately (Section 4.2). Use Sleep Easy™ function if temporary silence is needed.
LCD displays "AL" and beeps every 40 secondsAlarm in Absence triggeredA CO alarm occurred while you were away. Investigate potential CO sources and ventilate the area.
LCD displays "EOL"Fin de vie du produitReplace the detector with a new unit. The sensor is no longer reliable after 10 years.
No display or unit unresponsiveNo batteries, incorrect battery installation, or faulty unitCheck battery installation and polarity. Replace batteries. If still unresponsive, the unit may be faulty and require replacement.

6. Spécifications

FonctionnalitéSpécification
Numéro de modèleFA6812-EUX10
Type de capteurÉlectrochimique
Durée de vie du capteur10 années
Source d'énergie2 piles alcalines AA (incluses)
Volume de l'alarme85 dB(A) at 3 meters (minimum)
AfficherLCD numérique
Dimensions (L x l x H)120 x 73 x 35.5 mm
Poids145 gramme
Température de fonctionnement0°C à 40°C
Humidité de fonctionnement30% à 90% HR (sans condensation)
ConformitéBS EN 50291-1:2018, BS EN 50291-2:2019, CE Marked
Code UPC816317006860

7. Garantie et assistance

7.1 Informations sur la garantie

The FireAngel FA6812 Carbon Monoxide Detector is designed for long-term reliability. For specific warranty terms and conditions, please refer to the documentation included with your product or visit the official FireAngel webLe site. Les périodes de garantie peuvent varier selon la région.

7.2 Assistance clientèle

If you have any questions, require technical assistance, or need to report an issue with your FireAngel FA6812 detector, please contact FireAngel customer support. Contact details can typically be found on the product packaging or the official FireAngel website (www.fireangeltech.com).

Documents connexes - FA6812

Préview Manuel d'utilisation du détecteur de monoxyde de carbone FireAngel FA6812/FA6813
Manuel d'utilisation des détecteurs de monoxyde de carbone (CO) FireAngel FA6812 et FA6813, fournissant des instructions d'installation, de fonctionnement, de sécurité et d'entretien.
Préview Manuel d'utilisation du détecteur de monoxyde de carbone FireAngel CO-9X (durée de vie de 7 ans)
Manuel d'utilisation complet du détecteur de monoxyde de carbone FireAngel CO-9X (durée de vie de 7 ans). Découvrez l'installation, le fonctionnement, l'entretien, les consignes de sécurité et le dépannage.
Préview Manuel d'utilisation du détecteur multisensoriel FireAngel Plus : détecteur de fumée, de chaleur et de monoxyde de carbone
Manuel d'utilisation complet pour les détecteurs FireAngel Multisensor Plus et Multisensor Plus Kitchen, détaillant l'installation, le fonctionnement, la sécurité, le dépannage et les spécifications techniques pour la détection de fumée, de chaleur et de monoxyde de carbone.
Préview Manuel d'utilisation du détecteur de fumée sans fil FireAngel WST-630N
Manuel d'utilisation complet du détecteur de fumée sans fil FireAngel WST-630N. Découvrez la technologie Thermoptek, l'installation, le fonctionnement et les dispositifs de sécurité pour une détection incendie domestique fiable.
Préview Manuel d'utilisation du détecteur de monoxyde de carbone FireAngel NM-CO-10X-INT
This user manual provides essential information for the FireAngel NM-CO-10X-INT Carbon Monoxide Alarm, covering installation, positioning, operation, safety guidelines, and warranty. Suitable for homes, caravans, and boats, it helps protect against the dangers of carbon monoxide poisoning.
Préview FireAngel ST-620 Smoke Alarm User Manual: 10 Year Life
This user manual provides comprehensive instructions for the FireAngel ST-620 smoke alarm, detailing its 10-year lifespan, Thermoptek™ sensor technology, installation, operation, testing, maintenance, and troubleshooting. Ensure optimal fire safety with this essential guide.