Banner Engineering M18TUP14

Manuel d'utilisation du capteur de température industriel M18TUP14

Model: M18TUP14 | Brand: Banner Engineering

1. Introduction et plusview

The Banner Engineering M18TUP14 is an industrial temperature sensor designed for precise temperature measurement in various industrial applications. This sensor features a 1 Germanium Lens, providing accurate readings within a temperature range of -20°C to +300°C. It offers an analog 0-10V output for continuous temperature monitoring and a PNP alarm output for threshold detection. The robust design, including an IP67 rating, ensures reliable performance in demanding environments. This manual provides essential information for the safe and effective installation, operation, and maintenance of your M18TUP14 sensor.

2. Consignes de sécurité

Read all instructions carefully before installing or operating the M18TUP14 sensor. Failure to follow these instructions may result in product damage, property damage, or serious injury.

3. Contenu du colis

Vérifiez que tous les articles sont présents et non endommagés lors du déballage :

Si des composants sont manquants ou endommagés, contactez immédiatement votre fournisseur.

4. Spécifications

ModèleM18TUP14
FabricantIngénierie de la bannière
Plage de température-20°C à +300°C (-4°F à +572°F)
Vol d'approvisionnement d'exploitationtage12 V à 30 V CC
Type de sortieAnalog 0-10V, PNP Alarm
Type de lentille1 Germanium Lens
Longueur du câble2 m (6.5 pi)
Indice de protection IPIP67
Poids de l'article6.99 livre (environ 3.17 kg)

5. Configuration et installation

Proper installation is crucial for the accurate and reliable operation of the M18TUP14 sensor.

5.1 Montage

The M18TUP14 sensor features an M18 threaded barrel for easy mounting. Use appropriate mounting hardware (not included) to secure the sensor in the desired location. Ensure the sensor's lens is unobstructed and has a clear line of sight to the target area for temperature measurement. The IP67 rating ensures protection against dust and temporary immersion in water, making it suitable for harsh industrial environments.

M18TUP14 Industrial Temperature Sensor showing its threaded body, power and output indicators, and TEACH button.

Figure 1: M18TUP14 Industrial Temperature Sensor. The image displays the cylindrical, threaded body of the sensor, with a black end housing the power (PWR) and output (OUT) indicator LEDs, and a 'TEACH' button. The sensor terminates in a threaded connector for wiring.

5.2 Câblage

Connect the sensor to your control system according to the following general guidelines. Refer to the specific wiring diagram provided with your sensor for detailed connections. Ensure power is OFF before wiring.

6. Fonctionnement

Once installed and wired, the M18TUP14 sensor is ready for operation.

6.1 Power-Up and Indicators

Upon applying power, the PWR (Power) indicator LED on the sensor will illuminate, typically green, indicating that the sensor is receiving power. The DEHORS (Output) indicator LED will illuminate when the PNP alarm output is active (i.e., when the measured temperature exceeds the set alarm threshold).

6.2 Analog Output Reading

The 0-10V analog output provides a continuous representation of the measured temperature. You will need to scale this voltage reading in your control system (PLC, HMI, etc.) to convert it into a temperature value (e.g., degrees Celsius or Fahrenheit) based on the sensor's specified temperature range (-20°C to +300°C).

Par exempleample, 0V might correspond to -20°C and 10V to +300°C. Consult the sensor's data sheet for the exact scaling factor if not provided here.

6.3 Setting Alarm Threshold (TEACH Function)

The 'TEACH' button on the sensor is used to set the PNP alarm threshold. The exact procedure may vary slightly, but typically involves:

  1. Place the sensor in the environment or at the temperature you wish to set as the alarm threshold.
  2. Press and hold the 'TEACH' button for a specified duration (e.g., 2-5 seconds) until the OUT indicator flashes, indicating it has learned the new threshold.
  3. Release the button. The sensor is now configured, and the PNP alarm will activate when the temperature exceeds this newly taught value.

Refer to the detailed programming instructions in the full Banner Engineering product manual for advanced teaching modes or specific timing requirements.

7. Entretien

The M18TUP14 sensor is designed for minimal maintenance. However, periodic checks can ensure optimal performance and longevity.

8. Dépannage

If you encounter issues with your M18TUP14 sensor, consider the following common troubleshooting steps:

ProblèmeCause possibleSolution
Pas d'alimentation (voyant PWR éteint)No power supply; Incorrect wiring; Faulty power supply.Vérifiez les connexions d'alimentation et le volume.tage (12-30V DC). Verify wiring polarity. Test power supply.
Incorrect Analog Output ReadingSensor lens obstructed/dirty; Incorrect scaling in controller; Sensor outside temperature range.Clean sensor lens. Verify scaling parameters in your control system. Ensure target temperature is within -20°C to +300°C.
PNP Alarm Not TriggeringIncorrect alarm threshold set; Wiring issue; Temperature not reaching threshold.Re-teach the alarm threshold using the 'TEACH' button. Check PNP output wiring. Verify actual temperature.
Lectures intermittentesLoose wiring connections; Electrical interference; Unstable power supply.Secure all wiring connections. Ensure proper grounding. Use shielded cables if interference is suspected.

If the problem persists after attempting these steps, contact Banner Engineering technical support or your authorized distributor for further assistance.

9. Garantie et assistance

For information regarding the warranty of your M18TUP14 Industrial Temperature Sensor, please refer to the warranty statement provided by Banner Engineering or contact your point of purchase (e.g., Neutron USA). Technical support and additional resources can typically be found on the official Banner Engineering website ou en contactant leur service clientèle.

Fabricant: Ingénierie de la bannière

ASIN: B0F4JSFBPY

Documents connexes - M18TUP14

Préview Capteur de température infrarouge T-GAGE série M18T de Banner avec sortie analogique
Informations détaillées sur le capteur de température infrarouge T-GAGE de la série Banner M18T, y compris les caractéristiques, les modèles, les spécifications, le câblage, la configuration et la maintenance.
Préview Banner T-GAGE M18T Series Infrared Temperature Sensors: Features, Specifications, and Applications
Comprehensive guide to Banner Engineering's T-GAGE M18T Series Infrared Temperature Sensors, detailing features, model specifications, sensing capabilities, programming methods, dimensions, and accessories for industrial temperature measurement.
Préview Banner M18T Series T-GAGE® Temperature Sensor with Discrete Outputs | Technical Specifications
Detailed technical specifications, features, applications, and configuration guide for the Banner M18T Series T-GAGE® temperature sensor with discrete outputs. Includes wiring diagrams, sensor configuration, and product support information.
Préview WLS70 Industrial LED Strip Light (AC) - Product Manual & Specifications
Comprehensive product manual and specifications for the Banner WLS70 Industrial LED Strip Light (AC), detailing features, installation, technical data, accessories, and warranty. This guide provides essential information for industrial and harsh environment applications.
Préview Manuel d'utilisation du capteur radar Q90R R-GAGE® | Banner Engineering
Manuel d'utilisation complet du capteur radar Banner Q90R R-GAGE®, incluant la description du produit, son installation, sa configuration, ses spécifications et l'assistance technique. Découvrez comment installer et utiliser ce capteur radar industriel.
Préview Convertisseur de sortie analogique Banner R45C vers périphérique IO-Link : Guide de démarrage rapide
Guide de démarrage rapide du convertisseur de sortie analogique Banner R45C vers périphérique IO-Link. Découvrez la configuration, l'installation, les spécifications et le dépannage de ce convertisseur de capteur industriel robuste, conforme à la norme IP.