1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of the RAB Lighting B17 LED Bollard Light. This outdoor luminaire features field-adjustable wattage and selectable color temperature (CCT), designed for various outdoor applications.
Les principales caractéristiques comprennent :
- Energy-efficient LED with a 50,000-hour lifespan.
- Wat réglabletage : 24 W, 19 W ou 14 W.
- Selectable CCT: 3000K (Warm White), 4000K (Neutral White), or 5000K (Cool White).
- 0-10V dimming capability.
- Homologué UL pour les endroits humides.
- Durable metal construction with a glass shade.

Figure 1: RAB Lighting B17 LED Bollard Light (Model B17D shown).
2. Consignes de sécurité
AVERTISSEMENT: Risque d'électrocution. Coupez l'alimentation avant toute installation ou intervention. L'installation doit être effectuée par un électricien qualifié, conformément aux normes électriques nationales et locales en vigueur.
- Assurer le vol d'alimentationtage is correct for the fixture.
- Do not handle live components.
- Portez un équipement de protection individuelle (EPI) approprié.
- This fixture is suitable for wet locations. Ensure all connections are properly sealed to prevent water ingress.
- Ne modifiez pas le dispositif. Toute modification peut annuler la garantie et engendrer des risques pour la sécurité.
3. Contenu du colis
Vérifiez que tous les composants sont présents avant de commencer l'installation :
- B17 LED Bollard Light Fixture
- On-Off Switch (Included Components)
- Installation Hardware (e.g., mounting bolts, gaskets) - (Assumed, not explicitly listed but typical for such products)
- Manuel d'instructions (ce document)
4. Configuration et installation
Follow these steps for proper installation of the B17 LED Bollard Light:
- Préparez le site d'installation : Ensure the mounting surface is stable and level. Run electrical conduit and wiring to the desired location according to local codes.
- Débrancher l'alimentation : Coupez le courant au disjoncteur avant de commencer tout travail électrique.
- Mount the Bollard: Secure the bollard base to the mounting surface using appropriate hardware. Ensure a watertight seal if required by local codes.
- Effectuer les connexions électriques : Connect the fixture's wires to the supply wires. Follow standard wiring practices:
- Black to Line (L)
- Blanc à neutre (N)
- Green/Ground to Ground (G)
- Purple to Dimming (+) (for 0-10V dimming)
- Gray to Dimming (-) (for 0-10V dimming)
- Sélectionnez Wattage et CCT : Before closing the fixture, adjust the wattage and CCT switches located inside the fixture head. Refer to Section 5 for details.
- Secure the Fixture Head: Attach the fixture head to the bollard body, ensuring all seals are properly seated to maintain the wet location rating.
- Restaurer l'alimentation : Turn on power at the circuit breaker and test the light.

Figure 2: The B17 Bollard Light is UL Listed and rated for wet locations, ensuring durability in outdoor environments.
5. Mode d'emploi
5.1. Field-Adjustable Wattage
The B17 bollard light allows you to select the desired wattage output to optimize brightness and energy consumption. A switch located inside the fixture head enables selection between 24W, 19W, and 14W.
- 24W: Luminosité maximale.
- 19W: Medium brightness, reduced energy use.
- 14W: Lower brightness, maximum energy savings.
Pour régler : Disconnect power. Open the fixture head. Locate the wattage selection switch and move it to the desired setting. Close the fixture head and restore power.
5.2. Selectable Color Temperature (CCT)
The fixture offers three color temperature options to suit different aesthetic preferences and applications. A separate switch inside the fixture head allows selection between 3000K, 4000K, and 5000K.
- 3000 K : Warm White, ideal for creating a cozy and inviting atmosphere.
- 4000 K : Neutral White, suitable for general illumination and task lighting.
- 5000 K : Cool White, provides bright, crisp light, often used for security or modern aesthetics.
Pour régler : Disconnect power. Open the fixture head. Locate the CCT selection switch and move it to the desired setting. Close the fixture head and restore power.

Figure 3: Visual representation of adjustable wattage and selectable CCT settings.
5.3. Gradation 0-10 V
The B17 bollard light is compatible with 0-10V dimming systems. Connect the purple and gray dimming wires to a compatible 0-10V dimmer control. This allows for smooth adjustment of light output from 100% down to 10% (or lower, depending on dimmer specifications).
Ensure the dimmer is rated for LED loads and is compatible with 0-10V dimming protocols.
6. Entretien
The B17 LED Bollard Light is designed for minimal maintenance due to its long LED lifespan of 50,000 hours.
- Nettoyage: Nettoyez périodiquement l'extérieur du luminaire avec un chiffon doux et sec.amp cloth to remove dirt and debris. Do not use abrasive cleaners or solvents. Ensure power is off before cleaning.
- Inspection: Annually inspect the fixture for any signs of damage, loose connections, or wear. Ensure all seals remain intact to maintain weather resistance.
- Remplacement des LED : LEDs are integrated and not user-replaceable. The long lifespan minimizes the need for replacement.

Figure 4: The B17 LED Bollard Light offers a long 50,000-hour operational lifespan.
7. Dépannage
| Problème | Cause possible | Solution |
|---|---|---|
| La lumière ne s'allume pas. | Pas d'alimentation électrique. Connexion de câblage desserrée. Mot incorrecttage/CCT setting. | Check circuit breaker. Ensure power is on. Vérifiez que toutes les connexions des câbles sont bien fixées (coupez l'alimentation au préalable). Confirmer quoitage/CCT switches are set correctly. |
| La lumière vacille ou faiblit de façon inattendue. | Variateur incompatible. Loose dimming wire connection. Voltage fluctuations. | Ensure 0-10V dimmer is compatible with LED loads. Check purple and gray dimming wire connections. Consultez un électricien pour vérifier la stabilité de l'alimentation électrique. |
| L'intensité lumineuse est trop faible/élevée. | Mot incorrecttage réglage. | Ajustez le wattage selection switch inside the fixture head (power off first). |
| Une couleur claire n'est pas souhaitée. | Paramètre CCT incorrect. | Adjust the CCT selection switch inside the fixture head (power off first). |
8. Spécifications
| Fonctionnalité | Détail |
|---|---|
| Nom du modèle | B17 |
| Marque | Éclairage RAB |
| Quoitage | Field-Adjustable: 24W / 19W / 14W |
| Température de couleur (CCT) | Température de couleur sélectionnable : 3 000 K / 4 000 K / 5 000 K |
| Atténuation | 0-10V Dimmable |
| Durée de vie | 50,000 heures |
| Matériel | Metal body, Glass shade |
| Cote environnementale | Homologué UL pour les emplacements humides |
| Composants inclus | Interrupteur marche / arrêt |
| Code UPC | 192552028424 |
| ASIN | B0DY2FPPNS |
9. Garantie et assistance
For warranty information and technical support, please contact RAB Lighting directly. Refer to the official RAB Lighting webConsultez le site ou votre documentation d'achat pour connaître les conditions de garantie spécifiques et les coordonnées de contact.
RAB Lighting Contact: www.rablighting.com