1. Introduction
This manual provides essential information for the safe and efficient installation, operation, and maintenance of the TRU COMPONENTS Signal Pillar, model TC-12835336. This device is designed for industrial signaling applications, featuring red and green LED indicators with continuous or flashing light modes and an IP65 protection rating.
2. Consignes de sécurité
- Lisez attentivement toutes les instructions avant l'installation et l'utilisation.
- L'installation ne doit être effectuée que par du personnel qualifié.
- Assurez-vous que l'alimentation électrique est débranchée avant toute installation, maintenance ou dépannage.
- Vérifiez le bon voltage (24V) is supplied to prevent damage to the unit.
- Do not expose the device to conditions beyond its specified IP65 rating.
- Évitez toute exposition directe des yeux à la lumière LED pendant des périodes prolongées.
3. Produit terminéview
The TRU COMPONENTS Signal Pillar TC-12835336 is a robust signaling device with two LED segments (red and green) for clear visual indication in various industrial environments.

Figure 1 : TRU COMPONENTS Signal Pillar TC-12835336. This image displays the signal pillar with its black base, threaded mounting shaft, and two translucent LED segments: red on top and green below. A bundle of multi-colored wires extends from the base for electrical connection.
Composants:
- Segments LED : Red and Green, providing visual status.
- Logement: Durable black housing with a diameter of 55 mm.
- Filetage de montage : Pour une installation sécurisée.
- Faisceau de câblage: Multi-colored wires for power and control connections.
4. Spécifications
| Fonctionnalité | Détail |
|---|---|
| Numéro de modèle | TC-12835336 |
| Couleurs claires | Rouge, Vert |
| Modes d'éclairage | Continuous or Flashing |
| Diamètre | Ø 55 mm |
| Indice de protection | IP65 |
| Voltage | 24V |
| Fabricant | COMPOSANTS TRU |
| Pays d'origine | Chine |
5. Configuration et installation
- Coupure de courant : Ensure all power to the installation area is disconnected before beginning.
- Montage: Securely mount the signal pillar using its threaded base. Ensure the mounting surface is stable and capable of supporting the device.
- Câblage : Connect the signal pillar's wires to the appropriate 24V power supply and control system. Refer to the wiring diagram (if provided separately with the product) for specific connections for continuous or flashing modes. Typically, different wires control each LED segment and the flashing function.
- Label environnemental : Ensure the IP65 rating is maintained after installation by properly sealing all connections and mounting points, especially in environments where dust or water ingress is a concern.
- Connexion électrique : Une fois toutes les connexions sécurisées et vérifiées, rétablissez l'alimentation électrique du système.
6. Mode d'emploi
The TRU COMPONENTS Signal Pillar operates by receiving a 24V signal to illuminate its LED segments. The specific wiring configuration determines whether a segment illuminates continuously or flashes.
- Éclairage continu : Apply 24V to the designated wire for the desired LED segment (e.g., red or green) to achieve continuous illumination.
- Flashing Lighting: If wired for flashing operation, applying 24V to the corresponding wire will activate the flashing mode for that LED segment. Consult your system's wiring diagram for specific control signals.
- Multiple Segments: Both red and green segments can be activated independently or simultaneously, depending on the control system's design.
7. Entretien
The TRU COMPONENTS Signal Pillar is designed for low maintenance. Regular checks can ensure optimal performance.
- Nettoyage: Periodically clean the exterior of the signal pillar with a soft, damp chiffon. N'utilisez pas de nettoyants abrasifs ou de solvants.
- Inspection: Regularly inspect the housing and wiring for any signs of damage, wear, or loose connections.
- Intégrité du joint : For IP65 rated protection, ensure all seals and cable glands remain intact and properly tightened.
- Coupure de courant : Débranchez toujours l’alimentation avant d’effectuer toute opération de maintenance.
8. Dépannage
| Problème | Cause possible | Solution |
|---|---|---|
| Signal pillar does not illuminate. | No power supply; incorrect wiring; faulty LED segment. | Check 24V power supply; verify wiring connections against diagram; if power and wiring are correct, the LED segment may require replacement. |
| LED segment illuminates continuously instead of flashing (or vice-versa). | Incorrect wiring for flashing/continuous mode. | Review wiring diagram and ensure correct connections for the desired operating mode. |
| Fonctionnement intermittent. | Connexion électrique desserrée ; alimentation électrique instable. | Inspect all wiring connections for tightness; check power supply stability. |
Si les étapes de dépannage ne résolvent pas le problème, contactez le service client ou un technicien qualifié.
9. Garantie et assistance
For information regarding warranty coverage, technical support, or replacement parts, please refer to the documentation provided with your purchase or contact TRU COMPONENTS customer service. Keep your purchase receipt as proof of purchase.
Manufacturer: TRU COMPONENTS