FireAngel SW1-R

Manuel d'utilisation du détecteur de fumée optique FireAngel SW1-R alimenté par secteur

Model: SW1-R

1. Produit terminéview

The FireAngel SW1-R is a mains-powered optical smoke alarm designed to provide early warning of fire. It features a 9V backup battery to ensure continuous protection during power outages. The alarm emits a loud 85dB sound at 3 meters and includes LED visual indicators for clear alerts.

This optical smoke alarm is particularly effective at detecting slow-burning fires that produce thick white smoke, making it suitable for general living areas.

Caractéristiques principales :

FireAngel SW1-R Smoke Alarm front view

Figure 1 : Face avant view of the FireAngel SW1-R Mains Powered Optical Smoke Alarm.

FireAngel SW1-R Smoke Alarm with packaging and key features

Figure 2: FireAngel SW1-R Smoke Alarm highlighting its 9V backup battery, audible/visual alerts, and large test button.

2. Informations importantes sur la sécurité

Veuillez lire attentivement toutes les instructions avant l'installation et l'utilisation. Conservez ce manuel pour toute consultation ultérieure.

FireAngel SW1-R Smoke Alarm placement guidelines

Figure 3: Illustration of recommended placement guidelines for the smoke alarm, showing distance from walls and light fittings, and unsuitable locations.

3. Contenu du colis

Vérifiez que tous les articles sont présents et non endommagés à l'ouverture du colis :

4. Guide d'installation

Important: Installation should only be performed by a competent person or qualified electrician. Ensure the mains power supply is switched off at the consumer unit before commencing installation.

4.1. Étapes de pré-installation :

  1. Sélectionnez l'emplacement: Choose a suitable location on the ceiling, adhering to the placement guidelines (refer to Section 2).
  2. Débrancher l'alimentation : Turn off the mains electricity supply to the circuit where the alarm will be installed.
  3. Installer la batterie de secours : Open the battery compartment on the alarm unit and insert the supplied 9V battery, observing polarity. Close the compartment securely.

4.2. Mounting the Alarm:

  1. Points de forage marqués : Hold the base plate against the ceiling at your chosen location and mark the two drilling points.
  2. Trous de forage : Drill holes at the marked points and insert the rawl plugs.
  3. Plaque de base de montage : Secure the base plate to the ceiling using the provided screws.
  4. Connecter le câblage : Connect the mains wiring (Live, Neutral, Earth, and Interlink if applicable) to the terminal block provided. Ensure connections are secure and correct. The alarm unit connects to this terminal block.
  5. Attach Alarm Unit: Align the smoke alarm unit with the base plate and twist clockwise until it clicks securely into place.
FireAngel SW1-R Smoke Alarm easy installation steps

Figure 4: Visual guide for easy installation, showing steps like installing the backup battery, mounting the bracket, attaching the alarm, and connecting to mains power.

4.3. Interlinking Multiple Alarms:

The SW1-R can be hardwired and interconnected with up to 12 compatible FireAngel mains-powered smoke (SW1), heat (HW1), or carbon monoxide (CW1) alarms. To interlink, connect the interlink wire between the designated terminals on each alarm's base plate. When one interlinked alarm detects a hazard, all connected alarms will sound simultaneously.

4.4. Vérification après l'installation :

  1. Restaurer l'alimentation : Turn the mains electricity supply back on.
  2. Alarme de test : Press and hold the Test/Silence button for 5 seconds to confirm the alarm is functioning correctly. A loud, high-pitched sound indicates proper operation.

5. Mode d'emploi

5.1. Fonctionnement normal :

Under normal conditions, the alarm will periodically flash its LED indicator to show it is powered and monitoring for smoke. If smoke is detected, the alarm will sound a loud siren and the LED will flash rapidly.

5.2. Test/Silence Button:

5.3. Sleep Easy Function:

If the 9V backup battery is low, the alarm will emit a regular "chirp" sound. To temporarily silence these low battery chirps for up to 8 hours, press the Test/Silence button. This allows for an uninterrupted night's sleep while still maintaining protection. Replace the battery as soon as possible after using this function.

6. Entretien

Regular maintenance ensures the continued reliability and effectiveness of your smoke alarm.

FireAngel SW1-R Smoke Alarm maintenance tips

Figure 5: Visual summary of key maintenance recommendations for the smoke alarm, including monthly testing and quarterly vacuuming.

7. Dépannage

If your smoke alarm is not operating as expected, refer to the following table for common issues and solutions:

ProblèmeCause possibleSolution
L'alarme émet des bips intermittentsPile de secours 9V faible.Replace the 9V battery immediately. Use the Sleep Easy function if needed for temporary silence.
Alarm sounds without visible smoke (false alarm)Poussière ou débris dans la chambre de détection ; humidité élevée ; fumées de cuisson ; vapeur.Press the Test/Silence button to temporarily silence. Vacuum the alarm thoroughly. Relocate the alarm if it's consistently affected by cooking fumes or steam.
L'alarme ne sonne pas pendant le testNo mains power; flat 9V backup battery; faulty unit.Check mains power supply. Replace 9V battery. If problem persists, contact customer support.
Interlinked alarms do not all soundFaulty interlink wiring; incompatible alarms; too many alarms interlinked.Check interlink wiring connections. Ensure all interlinked alarms are compatible FireAngel models. Do not exceed 12 interlinked alarms.

8. Spécifications techniques

Numéro de modèleSW1-R
Type de capteurOptique (Photoélectrique)
Source d'énergieMains Powered (230V AC) with 9V DC Battery Backup
Volume de l'alarme85dB à 3 mètres
Interlink CapabilityUp to 12 compatible FireAngel mains-powered alarms
Dimensions du produit (P x L x H)4.2 cm (P) x 12.6 cm (L) x 12.6 cm (H)
Poids de l'article220 gramme
Température de fonctionnementConsultez l'emballage du produit pour connaître la gamme spécifique.
Taux d'humiditéConsultez l'emballage du produit pour connaître la gamme spécifique.
NormesBS EN 14604 : 2005
Code UPC816317004422
FireAngel SW1-R Smoke Alarm with UKCA and CE marks

Figure 6: The FireAngel SW1-R Smoke Alarm displaying its UKCA and CE certifications, indicating compliance with safety standards.

9. Garantie et support client

9.1. Informations sur la garantie :

The FireAngel SW1-R Mains Smoke Alarm comes with a Garantie de 5 ans À compter de la date d'achat. Cette garantie couvre les défauts de matériaux et de fabrication dans des conditions normales d'utilisation. Veuillez conserver votre preuve d'achat pour toute réclamation au titre de la garantie.

The warranty does not cover damage caused by misuse, accidental damage, unauthorized modifications, or failure to follow the instructions in this manual.

9.2. Assistance clientèle :

For technical assistance, warranty claims, or further information regarding your FireAngel SW1-R smoke alarm, please contact FireAngel customer support. Refer to the FireAngel official webPour obtenir les coordonnées les plus récentes, veuillez consulter le site web ou l'emballage du produit.

Website: www.fireangel.co.uk (Example lien (le lien réel peut varier selon la région)

Documents connexes - SW1-R

Préview Manuel d'utilisation du détecteur de fumée optique FireAngel SW1
User manual for the FireAngel SW1 Optical Smoke Alarm, providing installation, operation, maintenance, troubleshooting, warranty, and disposal information.
Préview Manuel d'utilisation du détecteur de chaleur FireAngel HW1 alimenté par secteur
Manuel d'utilisation complet du détecteur de chaleur FireAngel HW1 alimenté par secteur et doté d'une pile de secours 9 V. Ce manuel inclut des informations sur l'installation, le positionnement, la mise en sourdine, les options de connexion, l'entretien, le dépannage et la garantie.
Préview Manuel d'utilisation des détecteurs de fumée et de chaleur FireAngel : FA6611, FA6615, FA6620, FA6720
Manuel d'utilisation complet pour les détecteurs de fumée optiques FireAngel FA6611, FA6615 et FA6620 et le détecteur de chaleur FA6720. Ce manuel couvre l'installation, la maintenance, le dépannage, la garantie et la mise au rebut.
Préview Manuel d'utilisation du détecteur de fumée FireAngel ST-625-INT
Manuel d'utilisation complet du détecteur de fumée FireAngel ST-625-INT : installation, fonctionnalités, entretien et garantie. Ce guide fournit les informations essentielles de sécurité et les instructions d'utilisation.
Préview Manuel d'utilisation des détecteurs de fumée FireAngel FA6111, FA6115, FA6120 et du détecteur de chaleur FA6215
Manuel d'utilisation complet pour les détecteurs de fumée optiques FireAngel FA6111, FA6115, FA6120 et le détecteur de chaleur FA6215, couvrant l'installation, la maintenance, le dépannage, les fonctionnalités telles que Silence et Sleep Easy, la garantie et la mise au rebut.
Préview Manuel d'utilisation de l'avertisseur combiné de fumée et de monoxyde de carbone FireAngel SCB10
Manuel d'utilisation du FireAngel SCB10, un détecteur combiné de fumée et de monoxyde de carbone, fournissant des instructions complètes sur l'installation, le fonctionnement, l'entretien et la sécurité pour une utilisation résidentielle.