1. Introduction
This manual provides essential information for the safe and efficient operation of your Generac 12,500 Starting Watt Tri-Fuel Portable Generator, Model GP9500E TF. Please read all instructions carefully before operating the generator.

Image 1: The Generac GP9500E TF Portable Generator providing power during an outage.
2. Installation
2.1 Déballage et montage
Your generator comes with several components that require assembly before first use. Ensure all parts are present and undamaged.
- Huile moteur
- LP Hose with Regulator
- Batterie (pour démarrage électrique)
- Kit poignée et roue
- Manuel du propriétaire

Image 2: Included components in the Generac GP9500E TF package.
Installation de la roue et de la poignée : Attach the wheels and handles to the generator frame using the provided hardware. This enhances portability.
Ajout d'huile moteur : Locate the oil fill cap/dipstick. Add the provided engine oil to the crankcase. Do not overfill. Refer to the oil capacity in the specifications section.
Connexion de la batterie : Connect the battery terminals, ensuring correct polarity (red to positive, black to negative). The battery powers the electric start feature.
2.2 Alimentation du générateur
The Generac GP9500E TF is a tri-fuel generator, capable of running on gasoline, liquid propane (LP), or natural gas.
- Essence: Fill the 7.5-gallon fuel tank with fresh, unleaded gasoline. Do not use E85 or other ethanol blends exceeding 10%.
- Liquid Propane (LP): Connect the provided LP hose and regulator to a standard LP tank and the generator's LP inlet.
- Gaz naturel: Connect the generator to a natural gas supply line using appropriate fittings and hoses (not included). Consult a qualified professional for natural gas connections.
WARNING: Always operate the generator in a well-ventilated outdoor area, far from windows, doors, and vents, to prevent carbon monoxide poisoning.

Image 3: Tri-Fuel capabilities and estimated runtimes.
For a visual guide on initial setup, including adding oil and connecting the battery, please watch the following video:
Video 1: Demonstrates the initial setup, including adding oil, connecting the battery, and starting the Generac GP8000E generator.
3. Mode d'emploi
3.1 Panneau de configuration terminéview
Familiarize yourself with the generator's control panel before operation.

Image 4: Control Panel of the Generac GP9500E TF.
3.2 Démarrage du générateur
- Assurez-vous que le générateur soit placé sur une surface plane et dans un endroit extérieur bien ventilé.
- Vérifier les niveaux d'huile et de carburant.
- Select the desired fuel type (Gasoline, LP, or Natural Gas) using the fuel selector dial.
- Turn the engine switch to the 'START' position for electric start. If manual start is required, pull the recoil starter handle firmly.
- Once the engine starts, release the switch (for electric start) or the recoil handle.
- Laissez le générateur fonctionner quelques minutes pour qu'il chauffe avant de brancher des charges.
Watch this video for a demonstration of starting the generator:
Video 2: Demonstrates the starting procedure and features of a Generac portable generator.
3.3 Raccordement des appareils
Connect your appliances to the appropriate outlets on the control panel. The generator features multiple outlets:
- 20A, 120V 5-20R GFCI outlets
- 30A, 120/240V L14-30R outlet
- 40A, 120/240V 14-50R outlet
Assurez-vous que la quantité totale d'eautage of connected appliances does not exceed the generator's running wattage (9500 Watts on Gas). Overloading the generator can cause circuit breakers to trip.
4. Consignes de sécurité
4.1 Carbon Monoxide Safety
Your Generac GP9500E TF is equipped with Technologie COsense®, which automatically shuts down the generator if hazardous levels of carbon monoxide are detected. This feature provides powerful protection against carbon monoxide poisoning.
NEVER operate the generator indoors, in a garage, or in any enclosed space. Carbon monoxide is an odorless, colorless, and deadly gas.

Image 5: Key features of the Generac GP9500E TF, including COsense® Technology.
4.2 Précautions générales de sécurité
- Gardez les enfants et les animaux domestiques éloignés du générateur.
- Ne faites pas fonctionner le générateur dans des conditions humides.
- Assurez-vous que la génératrice est correctement mise à la terre.
- Never refuel a hot or running engine.
- Store fuel in approved containers in a well-ventilated area away from ignition sources.
5. Entretien
5.1 Entretien régulier
Regular maintenance is crucial for the longevity and performance of your generator. Refer to the maintenance schedule in the full owner's manual for detailed intervals.
- Vérifier le niveau d'huile : Before each use, check the engine oil level and add if necessary.
- Changer l'huile: Changez l'huile moteur après les 20 premières heures de fonctionnement, puis toutes les 100 heures ou une fois par an.
- Nettoyer/remplacer le filtre à air : Inspectez et nettoyez régulièrement le filtre à air. Remplacez-le s'il est très encrassé ou endommagé.
- Bougie d'allumage: Inspectez et nettoyez la bougie d'allumage chaque année. Remplacez-la si elle est usée.
- Système d'alimentation en carburant : Drain the fuel system if storing the generator for an extended period (over 30 days) or use a fuel stabilizer.
The generator features a low oil shutdown feature to protect the engine from damage when oil levels are insufficient.
6. Dépannage
6.1 Problèmes courants
- Le moteur ne démarre pas :
- Check fuel level and type.
- Ensure engine oil is at the correct level.
- Verify the engine switch is in the 'START' position.
- Vérifiez que la bougie d'allumage n'est pas encrassée ou endommagée.
- Aucune puissance de sortie :
- Vérifiez si des disjoncteurs ont sauté sur le tableau électrique. Réarmez-les si nécessaire.
- Assurez-vous que toutes les connexions sont sécurisées.
- Confirm the generator is running at the correct RPM.
- Le moteur s'arrête inopinément :
- Low oil level (check and refill).
- Overload (reduce connected appliances).
- COsense® activation (move generator to a more open, well-ventilated area).
7. Spécifications
| Fonctionnalité | Spécification |
|---|---|
| Marque | Générac |
| Nom du modèle | GP9500E TF |
| Numéro de modèle | 8061 |
| Wat de départtage | 12,500 watts |
| Courir Wattage (Gas) | 9,500 watts |
| Type de carburant | Gasoline, Liquid Propane, Natural Gas |
| Type de moteur | 4 temps |
| Volume du réservoir | 7.5 gallons |
| Runtime (Gas, 50% load) | Jusqu'à 10.5 XNUMX heures |
| Système d'allumage | Démarrage électrique |
| Caractéristiques spéciales | CO Sense, Electric Start, Low Oil Shutdown, Portable, Tri-Fuel |
| Dimensions du produit (L x l x H) | 27.2" x 26.94" x 27" |
| Poids de l'article | 227 livres |

Image 6: Generac GP9500E TF dimensions and weight.

Image 7: Guide to estimating power needs for various devices.
8. Garantie et assistance
8.1 Informations sur la garantie
Your Generac GP9500E TF Portable Generator comes with a Garantie limitée d'un an. Please refer to the full owner's manual for complete warranty terms and conditions.
8.2 Assistance clientèle
For technical assistance, parts, or service, please contact Generac customer support. Refer to the contact information provided in your owner's manual or visit the official Generac website.