ELEGRP 72611-BL

Manuel d'instructions de l'interrupteur à bascule triple ELEGRP Decorator, modèle 72611-BL

Model: 72611-BL

1. Introduction

Thank you for choosing the ELEGRP Decorator Triple Rocker Switch. This manual provides essential information for the safe installation, operation, and maintenance of your new switch. Please read these instructions thoroughly before beginning installation and retain them for future reference.

Informations importantes sur la sécurité

  • AVERTISSEMENT : RISQUE DE CHOC ÉLECTRIQUE. Always turn off power at the circuit breaker or fuse box before installation, servicing, or removing the switch.
  • Install in accordance with all national and local electrical codes. If you are unsure about any part of these instructions, consult a qualified electrician.
  • Utiliser uniquement avec du fil de cuivre ou recouvert de cuivre.
  • Ne pas utiliser dans des endroits humides.
  • Assurez-vous que toutes les connexions filaires sont sécurisées.

2. caractéristiques du produit

The ELEGRP Decorator Triple Rocker Switch is designed for reliable performance and ease of use, offering control for three separate lighting loads from a single gang box.

  • Rational Design: Features three smooth ON and OFF paddles with tactile feedback to prevent accidental operation.
  • Construction de haute qualité : Made from impact-resistant polycarbonate thermoplastic and solid steel for extended durability.
  • Mise à la terre automatique : Includes a self-grounding clip for automatic connection in properly grounded metal wall boxes.
  • Installation facile : Supports both back wiring and side wiring. Features break-off plaster ears for flush alignment and a shallow body design to fit standard junction boxes.
  • UL & CUL Listed: Strictly tested to UL Standards for safety and quality assurance.
Image showing the ELEGRP Triple Rocker Switch with features like Polycarbonate Thermoplastic, High Impact Resistant, Self-Grounding, Easy Installation, and UL/CUL Listed.

Figure 1: Key features of the ELEGRP Triple Rocker Switch, highlighting its durable construction and safety certifications.

3. Contenu du colis

Vérifiez que tous les composants sont présents avant l'installation :

  • 1 x ELEGRP Decorator Triple Rocker Switch (Model 72611-BL)
  • 1 x Matching Wall Plate (Screw Wall Plate, Glossy Black)
  • Vis de montage

4. Configuration et installation

Follow these steps carefully to install your ELEGRP Triple Rocker Switch.

Étapes de pré-installation

  1. Couper l'alimentation : Locate the circuit breaker or fuse that controls the switch location and turn off the power. Verify power is off using a voltage testeur.
  2. Retirer l'ancien interrupteur : Retirez soigneusement la plaque murale et l'interrupteur existants du boîtier mural. Débranchez les fils de l'ancien interrupteur.
  3. Inspecter le câblage : Identify the hot (line), neutral, ground, and load wires. If you are unsure, consult a qualified electrician.

Instructions de câblage

The ELEGRP Triple Rocker Switch offers two wiring options: side wiring and back wiring.

Diagram showing side wiring and back wiring options for the ELEGRP Triple Rocker Switch. Black screw for hot wire, brass screw for white/neutral, green screw for green/ground.

Figure 2: Wiring options for the switch, illustrating connections for hot, neutral, and ground wires.

  1. Fil de terre: Connect the green or bare copper ground wire from the wall box to the green grounding screw on the switch.
  2. Fil conducteur sous tension (ligne) : Connect the incoming hot (line) wire to the black screw terminal. This switch uses a common feed for all three loads.
  3. Câbles de charge : Connect the three load wires (one for each light/fixture) to the three brass screw terminals.
  4. Fil neutre : The neutral wire typically bypasses the switch and connects directly to the loads. Ensure proper neutral connections for your fixtures.

Montage du commutateur

  1. Repliez soigneusement les fils dans la boîte murale, en laissant suffisamment d'espace pour l'interrupteur.
  2. Insert the switch into the wall box and secure it with the provided mounting screws. Use the break-off plaster ears for flush alignment if needed.
  3. Attach the included wall plate over the switch and secure it with the smaller screws.
  4. Restaurer l'alimentation : Remettez le courant au niveau du disjoncteur ou du tableau électrique.
  5. Opération de test : Test each rocker paddle to ensure proper ON/OFF functionality for its respective load.
Diagram showing the compact dimensions of the ELEGRP Triple Rocker Switch, including front, side, and back viewavec des mesures en pouces et en millimètres.

Figure 3: Compact design and dimensions of the switch, ensuring compatibility with standard wall boxes.

5. Mode d'emploi

The ELEGRP Decorator Triple Rocker Switch provides simple control for three independent lighting or appliance loads.

  • Each of the three paddles operates independently.
  • To turn a connected load ON, press the upper part of the corresponding paddle.
  • To turn a connected load OFF, press the lower part of the corresponding paddle.
Image showing a single gang wall plate with three rocker switches, indicating how it saves space by controlling three lights from one location.

Figure 4: The triple rocker switch allows control of three separate loads from a single wall box, optimizing space.

6. Entretien

The ELEGRP Triple Rocker Switch requires minimal maintenance.

  • Nettoyage: To clean the switch and wall plate, wipe with a soft, damp Chiffon. N’utilisez pas de nettoyants abrasifs ni de solvants, car ils pourraient endommager la finition.
  • Inspection: Periodically check the switch and wall plate for any signs of damage or loose connections. If any issues are found, turn off power at the circuit breaker and address them promptly.

7. Dépannage

If you experience issues with your ELEGRP Triple Rocker Switch, refer to the following common troubleshooting steps:

ProblèmeCause possibleSolution
L'interrupteur ne s'allume/ne s'éteint pas.L'interrupteur n'est pas alimenté.
Connexion de fil lâche
Faulty bulb/fixture
Check circuit breaker/fuse. Ensure power is restored.
Turn off power, recheck all wire connections.
Effectuez le test avec une ampoule/un luminaire dont le fonctionnement est avéré.
Switch feels loose in wall boxVis de montage non serréesTurn off power, tighten mounting screws securely.
Wall plate does not sit flushWires are too bulky in the box
Switch not properly aligned
Carefully arrange wires to allow space.
Adjust switch position in the wall box.

If the problem persists after attempting these solutions, contact ELEGRP customer support or a qualified electrician.

8. Spécifications

SpécificationDétail
Numéro de modèle72611-BL
Mode de fonctionnementALLUMÉ ÉTEINT
Évaluation actuelle15 Amps
Vol d'exploitationtage125 volts
Type de contactNormalement ouvert
Type de connecteurClamp
Type de terminalClamp
Type de circuitParallèle
Type d'actionneurBascule
Dimensions du produit (L x l x H)7.17 x 4.41 x 3.46 pouces (18.21 x 11.20 x 8.79 cm)
Poids4.59 onces (130 grammes)
CertificationsHomologué UL et CUL

9. Informations sur la garantie

ELEGRP products are manufactured to high-quality standards and are backed by a limited warranty against defects in materials and workmanship. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official ELEGRP website.

10. Assistance

For technical assistance, product inquiries, or warranty claims, please contact ELEGRP customer support through the following channels:

  • En ligne: Visitez le site officiel ELEGRP Brand Store on Amazon.
  • E-mail: Refer to your product packaging or the brand store for specific contact email.

Documents connexes - 72611-BL

Préview Guide d'installation de l'interrupteur variateur intelligent ELEGRP
Ce document fournit les instructions d'installation de l'interrupteur variateur intelligent ELEGRP, pour les configurations unipolaires et à trois voies. Il détaille le câblage, la configuration et la compatibilité avec les assistants vocaux domotiques tels qu'Alexa et Google Assistant.
Préview Guide d'installation de la prise combinée et du chargeur USB ELEGRP
Instructions d'installation détaillées et spécifications de la prise combinée ELEGRP et du chargeur USB, y compris les caractéristiques, les schémas de câblage, la compatibilité et les avertissements de sécurité.
Préview Guide d'installation de la prise et du chargeur USB combinés ELEGRP R16
Instructions d'installation, spécifications et consignes de sécurité pour la prise et le chargeur USB combinés ELEGRP R16. Comprend deux ports USB, une prise standard et un câblage facile. Garantie et conformité FCC incluses.
Préview Manuel d'utilisation du dispositif domotique ELEGRP : Connexion des applications et des appareils
Manuel d'utilisation complet pour les appareils domotiques ELEGRP, détaillant comment télécharger l'application ELEGRP HOME, connecter les appareils via Wi-Fi (2.4 GHz uniquement) et les intégrer à Amazon Alexa et Google Assistant.
Préview Bulletin produit ELEGRP sur les capteurs de présence et d'inoccupation
Fiche produit du capteur de présence et d'absence d'ELEGRP, détaillant les caractéristiques, les avantages et les spécifications des modèles de capteurs de présence et d'absence.
Préview Instructions d'installation de la prise combinée / chargeur USB
Instructions d'installation de la prise combinée/chargeur USB : caractéristiques, spécifications, compatibilité et schémas de câblage. Consignes de sécurité et mises en garde incluses.