1. Introduction
This manual provides instructions for the proper use and maintenance of the Dasqua 7 Piece 0-16-Inch Electronic Depth Gage Set, model 4710-1205. This electronic depth gage is designed for precise depth measurements in various industrial and scientific applications. It features a digital display for clear readings and is constructed for durability and accuracy.

Image 1.1: The Dasqua 7 Piece 0-16-Inch Electronic Depth Gage Set, showing the main unit and various measurement rods.
2. Contenu du colis
Vérifiez que tous les composants sont présents dans le package :
- Electronic Depth Gage Unit
- Set of Measurement Rods (7 pieces)
- Étui de rangement
- Lettre de garantie

Image 2.1: The complete Dasqua Electronic Depth Gage Set, including the main unit, measurement rods, and storage case.
3. Principales caractéristiques
- Résolution: 0.0005-inch / 0.01mm for precise measurements.
- Conformité aux normes : Manufactured in accordance with DIN863 standards.
- Broche: Hardened, ground, and lapped for enhanced accuracy.
- Versatilité: Designed to accommodate a broad range of measurement applications.
- Afficher: Large, digital display for clear and quick readings.
- Construction: Hardened stainless steel base and rods resist wear, ensuring durability and consistent accuracy.
- Remise à zéro : Ability to reset to zero at any position for comparative depth measurements.
4. Instructions de configuration
4.1. Installation de la batterie
The electronic depth gage typically uses a CR2032 lithium coin cell battery. To install or replace the battery:
- Locate the battery compartment cover on the back of the digital display unit.
- Utilisez un petit tournevis ou une pièce de monnaie pour ouvrir le couvercle.
- Insérez une nouvelle pile CR2032 avec le côté positif (+) vers le haut.
- Replacez soigneusement le couvercle du compartiment à piles.
4.2. Attaching Measurement Rods
Select the appropriate measurement rod for the desired depth range. The set includes rods of various lengths.
- Identify the threaded end of the measurement rod.
- Carefully screw the rod into the threaded hole at the bottom of the depth gage's base until it is finger-tight. Do not overtighten.
- Ensure the rod is securely attached and straight.

Image 4.1: The electronic depth gage with a measurement rod properly attached to its base.

Image 4.2: A selection of the hardened stainless steel measurement rods provided with the depth gage set.
5. Mode d'emploi
5.1. Marche/Arrêt
- Appuyez sur le MARCHE/ARRÊT bouton pour allumer l'appareil.
- Appuyez sur le MARCHE/ARRÊT button again to power off the device.
5.2. Unit Conversion (Inch/Millimeter)
- Appuyez sur le mm/po button to switch between millimeter (mm) and inch (in) units. The selected unit will be displayed on the screen.
5.3. Réglage du zéro
The zero-reset function allows for comparative measurements or setting a reference point.
- Place the depth gage on a flat, stable reference surface, ensuring the measurement rod is fully retracted or resting on the surface.
- Appuyez sur le ZÉRO button. The display will show '0.000' or '0.00'.
5.4. Prendre une mesure
- Ensure the depth gage is zeroed on a reference surface.
- Place the base of the depth gage firmly on the surface from which the depth is to be measured.
- Lower the measurement rod into the hole or recess until its tip contacts the bottom.
- Lisez la mesure directement sur l'écran numérique.
5.5. Fonction de maintien
- Appuyez sur le PRISE bouton permettant de figer la lecture actuelle affichée.
- Appuyez sur le PRISE Appuyez à nouveau sur le bouton pour libérer la lecture et revenir à la mesure en direct.

Image 5.1 : Détail view of the digital display, showing the ON/OFF, mm/in, HOLD, and ZERO buttons.
6. Entretien
6.1. Nettoyage
- Wipe the depth gage and rods with a clean, dry, lint-free cloth after each use.
- Pour les saletés tenaces, utilisez un chiffon légèrement frotté.ampened with isopropyl alcohol. Avoid harsh chemicals or solvents.
- Ensure no liquid enters the electronic components.
6.2. Stockage
- Store the depth gage in its protective case when not in use.
- Conservez l'appareil dans un endroit sec, à l'abri de la lumière directe du soleil, des températures extrêmes et d'une forte humidité.
- En cas de stockage prolongé, retirez la batterie pour éviter les fuites.
6.3. Remplacement de la batterie
Replace the battery when the display becomes dim or erratic. Refer to Section 4.1 for battery installation instructions.
7. Dépannage
- L'écran est vide ou sombre :
Check battery installation. Replace the battery if necessary. Ensure the device is powered on. - Lectures inexactes :
Ensure the depth gage is properly zeroed on a flat reference surface. Clean the measurement rod and base to remove any debris. Verify the measurement rod is securely attached. - Boutons non réactifs :
Vérifiez le niveau de la batterie. Si le problème persiste après le remplacement de la batterie, contactez le service client.
8. Spécifications du produit
| Spécification | Détail |
|---|---|
| Numéro de modèle | 4710-1205 |
| Plage de mesure | 0-16 pouces / 0-400 mm |
| Résolution | 0.0005 pouce / 0.01 mm |
| Précision | 0.0015 pouce / 0.03 mm |
| Matériel | Acier inoxydable trempé |
| Source d'énergie | CR2032 Battery (typical) |
| Dimensions du colis | 9 x 5 x 2 pouces |
| Poids de l'article | 12.8 onces |

Image 8.1: Detailed specifications and dimensional diagram for the Dasqua 0-16 inch Electronic Depth Gage Set.
9. Garantie et assistance
This product is supplied with a warranty letter. For specific warranty terms and conditions, please refer to the documentation included in your package. For technical support, service, or inquiries regarding your Dasqua 4710-1205 Electronic Depth Gage Set, please contact the manufacturer directly through their official websites ou canaux de service client.