Dasqua 3230-8115-A

Manuel d'utilisation du comparateur de hauteur numérique à deux colonnes Dasqua 3230-8115-A

Model: 3230-8115-A | Brand: Dasqua

1. Introduction

This manual provides comprehensive instructions for the safe and effective use, maintenance, and troubleshooting of your Dasqua 3230-8115-A Digital Dual-Column Height Gauge. Please read this manual thoroughly before operating the device to ensure optimal performance and longevity.

1.1 Produit terminéview

The Dasqua 3230-8115-A is a precision digital height gauge designed for accurate measurement of height, depth, and step dimensions. It features a robust dual-column design for stability and a clear digital display for easy reading.

Dasqua 3230-8115-A Digital Dual-Column Height Gauge front view

Figure 1.1 : Face avant view of the Dasqua 3230-8115-A Digital Dual-Column Height Gauge, showing the digital display and measuring jaw.

Dasqua 3230-8115-A Digital Dual-Column Height Gauge rear view

Figure 1.2 : Arrière view of the height gauge, showing the handwheel for precise vertical adjustment.

Dasqua 3230-8115-A Digital Dual-Column Height Gauge detailed features

Figure 1.3 : Détaillé view highlighting key features such as the fine adjustment mechanism, measuring scale, and stable base.

2. Consignes de sécurité

To ensure safe operation and prevent damage to the instrument or injury to the user, please observe the following safety guidelines:

3. Installation

3.1 Déballage et inspection initiale

Carefully remove the height gauge from its packaging. Inspect the instrument for any signs of damage that may have occurred during transit. Ensure all components listed in the packing list are present.

3.2 Installation de la batterie

The digital display requires a CR2032 lithium coin cell battery. To install or replace the battery:

  1. Locate the battery compartment cover on the side of the digital display unit.
  2. Faites glisser le couvercle pour l'ouvrir dans le sens indiqué par la flèche.
  3. Insérez une nouvelle pile CR2032 avec le côté positif (+) orienté vers le haut.
  4. Fermez soigneusement le couvercle du compartiment à piles.
Dasqua 3230-8115-A Digital Dual-Column Height Gauge battery compartment

Figure 3.1: Close-up of the battery compartment, showing the location for CR2032 battery insertion.

3.3 Préparation à la mesure

Place the height gauge on a stable, flat, and clean surface. Ensure the measuring surface of the workpiece is also clean and free of burrs or debris.

4. Mode d'emploi

4.1 Panneau de configuration terminéview

Familiarize yourself with the functions of the buttons on the digital display unit:

Dasqua 3230-8115-A Digital Dual-Column Height Gauge control panel with labeled buttons

Figure 4.1: Digital display control panel with numbered buttons and their corresponding functions.

4.2 Procédure de mesure de base

  1. Appuyez sur le MARCHE/ARRÊT button to power on the height gauge.
  2. Select the desired unit of measurement (mm or inch) by pressing the mm/po bouton.
  3. Clean the measuring surface of the height gauge base and the workpiece.
  4. Lower the measuring jaw until it makes contact with the reference surface (e.g., the surface the workpiece rests on).
  5. Appuyez sur le ZERC/ABS button to set the display to zero at this reference point. This establishes your measurement origin.
  6. Carefully raise the measuring jaw using the handwheel until it makes contact with the feature you wish to measure on the workpiece.
  7. Lisez la mesure directement sur l'écran numérique.

4.3 Adjusting the Measuring Jaw

The measuring jaw can be adjusted for different measurement tasks. Loosen the locking screw, slide the jaw to the desired position, and then tighten the screw to secure it.

Dasqua 3230-8115-A Digital Dual-Column Height Gauge measuring jaw adjustment

Figure 4.2: Illustration of how to adjust and secure the measuring jaw for various applications.

5. Entretien

5.1 Nettoyage

Regular cleaning is essential for maintaining the accuracy and lifespan of your height gauge. Use a clean, soft, lint-free cloth to wipe down all surfaces. For stubborn dirt, a small amount of isopropyl alcohol can be used, but avoid contact with the digital display. Never use abrasive cleaners or solvents.

5.2 Stockage

When not in use, store the height gauge in its original protective case in a dry, temperature-controlled environment. Avoid areas with high humidity, dust, or direct sunlight. Ensure the measuring jaw is not clamped tightly to prevent unnecessary stress on the mechanism.

5.3 Remplacement de la batterie

Replace the CR2032 battery when the display becomes dim or shows a low battery indicator. Refer to Section 3.2 for detailed battery installation instructions.

6. Dépannage

This section addresses common issues you might encounter with your height gauge. If the problem persists after attempting these solutions, please contact customer support.

ProblèmeCause possibleSolution
L'affichage ne s'allume pas.Batterie déchargée ou mal installée.Replace the battery (CR2032) and ensure it is installed with correct polarity.
Lectures inexactes.Dirty measuring surfaces; instrument not zeroed correctly; environmental factors (temperature fluctuations).Clean all measuring surfaces. Re-zero the instrument. Ensure stable operating environment.
Display flickering or unstable.Low battery; electromagnetic interference.Replace battery. Move the instrument away from strong electromagnetic fields.
Measuring jaw movement is stiff.Accumulated dirt or debris on the columns; locking screw too tight.Clean the columns thoroughly. Loosen the locking screw slightly.

7. Spécifications

Technical specifications for the Dasqua 3230-8115-A Digital Dual-Column Height Gauge:

FonctionnalitéDétail
Numéro de modèle3230-8115-A
Plage de mesure0 à 600 mm
FabricantDasqua
Dimensions du colis89 x 30 x 18.5 cm
Poids de l'article10.92 kg
Première date disponible26 janvier 2024

8. Garantie et assistance

Dasqua products are manufactured to high quality standards and are typically backed by a manufacturer's warranty. Please refer to the warranty letter included with your product for specific terms and conditions regarding coverage and duration.

Dasqua 3230-8115-A Digital Dual-Column Height Gauge with packaging and warranty letter

Figure 8.1: The height gauge shown alongside its packaging and the included warranty letter.

For technical assistance, spare parts, or warranty claims, please contact your authorized Dasqua dealer or the customer support channel provided at the point of purchase. When contacting support, please have your model number (3230-8115-A) and purchase details ready.

Documents connexes - 3230-8115-A

Préview Jauge de hauteur numérique à double faisceau SB-057 : consignes de sécurité, de manipulation et d'élimination
Consignes de sécurité complètes, précautions de manipulation, consignes environnementales et procédures d'élimination pour le mesureur de hauteur numérique à double faisceau SB-057 de Dasqua. Données techniques et informations sur la batterie incluses.
Préview Micromètre numérique extérieur étanche Dasqua IP65 : instructions d'utilisation
Instructions complètes sur le produit pour le micromètre extérieur numérique étanche Dasqua IP65, couvrant l'utilisation, la structure, les boutons, la batterie, le dépannage et les précautions.
Préview Instructions d'utilisation du pied à coulisse numérique Dasqua IP67
Instructions complètes pour le pied à coulisse numérique Dasqua IP67, couvrant les directives de performances, l'élimination, le dépannage, les spécifications et les instructions de fonctionnement.
Préview Manuel d'instructions du pied à coulisse à vernier/à cadran Dasqua
Manuel d'instructions pour les pieds à coulisse à vernier et à cadran Dasqua, couvrant les structures, la lecture des mesures, l'utilisation courante, l'utilisation spéciale des pieds à coulisse, les précautions et le dépannage.
Préview Indicateur numérique avec codeur linéaire - Informations techniques et de sécurité
Consignes de sécurité, directives de manipulation et spécifications techniques pour la jauge indicatrice numérique DASQUA avec codeur linéaire (modèles DQ-25001, DQ-25002).
Préview Instructions pour la règle d'angle numérique Dasqua
Instructions complètes pour la règle d'angle numérique Dasqua, couvrant les fonctions, les caractéristiques, la maintenance, le dépannage et les modes de fonctionnement tels que NORMAL, CROWN et CUS.