ACiQ B0DHFF2DKL

ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System User Manual

Model: B0DHFF2DKL

1. Introduction

This manual provides essential information for the installation, operation, and maintenance of your ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System. This system is designed to provide efficient heating and cooling for residential and light commercial applications. Please read this manual thoroughly before attempting any installation or operation to ensure proper function and safety.

2. Consignes de sécurité

Always prioritize safety. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Consult a qualified installer, service agency, or the gas supplier for information or assistance. The information contained in this manual is intended for use by qualified service personnel only.

  • Sécurité électrique : Ensure the power supply is disconnected before performing any service or maintenance. All electrical wiring must comply with local and national electrical codes.
  • Manipulation du réfrigérant : This system uses R-454B refrigerant. Only certified technicians should handle refrigerants.
  • Installation: Installation must be performed by a licensed HVAC professional.
  • Équipement de protection individuelle : Always wear appropriate personal protective equipment (PPE) such as gloves and safety glasses during installation and maintenance.

3. Principales caractéristiques

  • Technologie Inverter : Assure un contrôle précis de la température, une consommation d'énergie réduite et un fonctionnement plus silencieux.
  • Haute efficacité : 18.8 SEER2 and 9.7 HSPF2 ratings for energy savings.
  • Large plage de fonctionnement : Reliable performance from -13°F to 122°F.
  • Fonctionnement silencieux : Indoor noise levels as low as 44 dBA, outdoor unit at 60 dBA.
  • Composants durables : Rotary compressor, aluminum coil, and fiberglass-free insulation.
  • Réfrigérant écologique : Utilizes R-454B refrigerant.
  • Installation flexible : Supports horizontal and vertical air handler installation.
  • Commandes intelligentes : Compatible with wired controllers, WiFi, and third-party thermostats.
  • Integrated Back-up Heat: Includes a 10kW back-up heat kit for supplemental heating.

4. Composants terminésview

The ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System includes the following main components:

  • Outdoor Condensing Unit (Heat Pump)
  • Unité de traitement d'air intérieure
  • 10kW Back-up Heat Kit
  • 30' Line Set
  • Gauge Electrical Whip
  • 60A Non-Fused Disconnect Switch
  • Thermostat WiFi
  • Surge Protector
  • CPS Charging Adapter
  • Manchon mural
ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System components

Figure 1 : Surview of the ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System, showing the outdoor unit, indoor air handler, 10kW back-up heat kit, thermostat, line set, and various installation accessories.

5. Configuration et installation

Installation of this ACiQ heat pump system requires specialized knowledge and tools. It must be performed by a qualified and licensed HVAC technician to ensure safety, compliance with local codes, and optimal performance. Refer to the detailed installation manual provided with the product for specific instructions.

5.1 Vérifications avant l'installation

  • Verify that the electrical supply matches the unit's requirements (Indoor: 115/208/230V, 60Hz, 1Ph; Outdoor: 208/230V, 60Hz, 1Ph).
  • Veillez à prévoir un espace suffisant pour les unités intérieures et extérieures, permettant une bonne circulation de l'air et un accès facile pour la maintenance.
  • Confirm that the maximum piping length (164 ft / 50m) and height difference (82 ft / 25m) are not exceeded.

5.2 Air Handler Installation

The indoor air handler unit is designed for flexible installation, supporting upflow, downflow, and horizontal configurations to suit various space requirements.

Multi-Positional Air Handler Unit installation options

Figure 2 : Diagram illustrating the multi-positional capabilities of the indoor air handler unit, showing options for upflow, downflow, and horizontal installation.

5.3 Emplacement de l'unité extérieure

Consider the outdoor unit's dimensions and required clearances for optimal performance and maintenance. The unit features a compact design compared to traditional systems.

Outdoor unit size comparison with traditional units

Figure 3 : Graphic comparing the smaller footprint of the ACiQ outdoor unit (20 inches clearance) versus a traditional unit (36 inches clearance), highlighting its high efficiency and self-cleaning features.

6. Mode d'emploi

Your ACiQ heat pump system offers advanced control options for comfortable and efficient operation.

6.1 Modes de fonctionnement de base

  • Mode de refroidissement : Provides cooling with a capacity of 31,000 BTU/hr. Operates efficiently from -13°F to 122°F ambient temperatures.
  • Mode de chauffage : Provides heating with a capacity of 30,000 BTU/hr at 47°F. Reliable warmth down to -13°F. The 10kW back-up heat kit provides supplemental heat when needed.
  • Mode ventilateur : Il fait circuler l'air sans le chauffer ni le refroidir.
  • Mode automatique: Bascule automatiquement entre le chauffage et le refroidissement pour maintenir la température réglée.
ACiQ outdoor unit operating in extreme heat

Figure 4 : The ACiQ outdoor unit installed on a patio, demonstrating its ability to operate effectively in extreme heat conditions, up to 122°F.

ACiQ outdoor unit operating in extreme cold

Figure 5 : The ACiQ outdoor unit partially covered in snow, illustrating its capability to operate in extreme cold temperatures, down to -13°F.

6.2 Commandes intelligentes

The system can be controlled via the included wired thermostat, WiFi-enabled app, or compatible third-party thermostats. The WiFi app allows for remote control and monitoring of your system.

ACiQ Smart Home app and wired thermostat

Figure 6 : Image showing the ACiQ Smart Home mobile application interface on a smartphone alongside a wired thermostat, demonstrating the system's smart control capabilities for climate management.

7. Entretien

Regular maintenance ensures the longevity and efficiency of your ACiQ heat pump system. Always disconnect power before performing any maintenance.

  • Remplacement du filtre à air : Check and replace air filters in the indoor air handler every 1-3 months, or more frequently if needed. Dirty filters restrict airflow and reduce efficiency.
  • Nettoyage de l'unité extérieure : Keep the outdoor unit free from debris, leaves, and dirt. Periodically clean the coils with a soft brush or water hose (ensure power is off).
  • Système d'évacuation : Veillez à ce que le tuyau d'évacuation des condensats soit dégagé et exempt de blocages afin d'éviter tout débordement d'eau.
  • Contrôle professionnel : Schedule annual inspections and maintenance by a qualified HVAC technician.

8. Dépannage

This section provides solutions for common issues. For complex problems, contact a qualified HVAC technician.

  • Pas d'alimentation : Check circuit breakers and ensure the disconnect switch is in the ON position.
  • Chauffage/refroidissement insuffisants : Verify thermostat settings, check air filters for blockage, and ensure outdoor unit is not obstructed.
  • Bruits inhabituels : De légers bruits de fonctionnement sont normaux. Des bruits forts ou inhabituels peuvent indiquer un problème nécessitant une inspection par un professionnel.
  • Fuites d'eau : Check condensate drain line for blockages.

9. Spécifications

Dimensions of ACiQ indoor and outdoor units

Figure 7 : Image displaying the dimensions of both the indoor air handler unit (49.02" H x 21.02" W x 21.02" D) and the outdoor condensing unit (35.04" H x 37.24" W x 16.14" D).

Cooling capacity chart for ACiQ heat pump

Figure 8 : Chart detailing the cooling capacity of the ACiQ system at various outdoor temperatures: 86°F (118% capacity), 95°F (113% capacity), 110°F (99% capacity), and 122°F (48% capacity).

Heating capacity chart for ACiQ heat pump

Figure 9 : Chart detailing the heating capacity of the ACiQ system at various outdoor temperatures: -22°F (N/A), -13°F (41% capacity), 0°F (57% capacity), 17°F (70% capacity), and 32°F (73% capacity).

FonctionnalitéDétail
Capacité de refroidissement31,000 BTU/h
Capacité de chauffage30,000 BTU/hr (at 47°F)
Cote SEER218.8
Indice de protection solaire HSPF29.7
Type de réfrigérantR-454B
Alimentation de l'unité intérieure115/208/230V, 60Hz, 1Ph
Alimentation électrique pour unité extérieure208/230 V, 60 Hz, monophasé
Longueur de tuyauterie maximale164 pieds (50 m)
Max Height Difference82 pieds (25 m)
Indoor Unit Dimensions (W × D × H)21.02 po × 21.02 po × 49.02 po
Outdoor Unit Dimensions (W × D × H)37.24 po × 16.14 po × 31.89 po
Poids net de l'unité intérieure128.97 livres
Poids net de l'unité extérieure164.02 livres

10. Garantie et assistance

ACiQ offers a comprehensive warranty for this heat pump system:

  • Garantie des pièces : 7 ans
  • Garantie du compresseur : 12 ans

These warranty terms are valid when the system is installed by a certified technician and registered online with the manufacturer. For technical support, service inquiries, or warranty claims, please refer to the contact information provided in your product packaging or visit the official ACiQ website.

Documents connexes - B0DHFF2DKL

Préview Systèmes de chauffage monozone standard ACiQ 9K-24K : Manuel d’installation et d’utilisation
Manuel d'installation et d'utilisation des systèmes de chauffage monozone standard ACiQ 9K-24K. Ce guide détaille l'installation, le fonctionnement, la sécurité et l'entretien des climatiseurs ACiQ, y compris les spécificités des modèles et les informations relatives au fluide frigorigène R454B.
Préview Manuel d'installation des systèmes d'onduleurs centraux ACiQ
Manuel d'installation complet pour les systèmes de climatisation et de pompe à chaleur ACiQ Central Inverter, détaillant les précautions de sécurité, la tuyauterie de réfrigérant, l'installation de l'unité extérieure, le câblage, les spécifications d'alimentation, l'évacuation de l'air et les procédures de test.
Préview Manuel d'installation et d'utilisation du module de traitement d'air mural ACiQ et du condenseur monozone pour températures extrêmes
Ce manuel fournit des instructions détaillées sur l'installation, le fonctionnement et la sécurité des unités de traitement d'air murales ACiQ et des condenseurs monozones à chaleur extrême, couvrant les modèles ACIQ-06W-HH-MD à ACIQ-24ZPL-HP230C.
Préview Manuel d'installation de l'unité extérieure des systèmes à onduleur central ACiQ
Manuel d'installation complet pour les unités extérieures des systèmes ACiQ Central Inverter, couvrant les précautions de sécurité, la tuyauterie de réfrigérant, le câblage, l'installation de l'unité et les procédures de test pour des modèles tels que ACiQ-18-AC, ACiQ-24-AC, ACiQ-18-EHPB et autres.
Préview Système de pompe à chaleur canalisée ACiQ nouvelle génération : Guide de démarrage rapide pour le câblage du thermostat
Ce guide fournit les informations essentielles pour le raccordement des thermostats au système de pompe à chaleur gainable ACiQ Next Gen. Il détaille les options de raccordement recommandées et alternatives, notamment les réglages des commutateurs DIP et les configurations des borniers pour différents types de thermostats.
Préview Manuel d'installation et d'utilisation du système de traitement d'air et du condenseur ACiQ Essentials Mini-Split
Manuel d'installation et d'utilisation complet pour les systèmes de traitement d'air et de condensation ACiQ Essentials Mini-Split. Ce manuel couvre les consignes de sécurité, l'identification des pièces, le fonctionnement de la télécommande, les procédures d'installation, les essais, la maintenance et le dépannage pour différents modèles. Il inclut également des informations essentielles concernant l'entretien des systèmes utilisant le fluide frigorigène inflammable R454B, en insistant sur les protocoles de sécurité et la conformité réglementaire. Destiné aux installateurs professionnels et aux utilisateurs finaux, il garantit un fonctionnement sûr et efficace des systèmes de pompe à chaleur mini-split ACiQ.