Introduction

The Irfora ET13S is a versatile 2-in-1 device combining a thermal imager and a 10,000-count multimeter. This integrated solution is designed for temperature detection and electrical parameter measurement across various fields such as transportation, energy, and electronics manufacturing. Its compact and lightweight design ensures portability for electricians and maintenance technicians.

Equipped with a 2.8-inch touchscreen, the device offers a 192x192 infrared resolution for clear imaging. It supports one-button access to functions and allows users to set parameters for accurate measurements. Both Chinese and English display options are available.

The thermal imager function displays maximum, minimum, and center temperatures, providing a comprehensive understanding of temperature distribution. It includes five color palettes (iron red, rainbow, fusion, white-hot, and white-hot highlight) and an automatic hotspot tracking function to quickly identify temperature anomalies.

The multimeter offers extensive functions including DC/AC voltage, resistance, diode, continuity, and capacitance measurements. It also features an analog bar display, room temperature display, automatic measurement, and NCV non-contact voltage test. Data logging and transfer to a PC via USB Type-C are supported for in-depth analysis.

The device is powered by a built-in 3.7V 1000mAh lithium battery, rechargeable via USB. Intelligent power-saving features like automatic screen shutdown and power-off extend battery life, enhancing efficiency and portability.

Irfora ET13S 2-in-1 Thermal Imager Multimeter
Un avant view of the Irfora ET13S 2-in-1 Thermal Imager Multimeter, showcasing its compact design and large display.
Irfora ET13S 2-in-1 design features
An image illustrating the key features of the ET13S, emphasizing its 2-in-1 thermal imager and multimeter capabilities, 192x192 IR resolution, 10,000 counts multimeter, and 2.8-inch touchscreen.
Irfora ET13S applicable scenarios
A collage of images showing various applications of the ET13S, including inspection and repair of circuit boards, power maintenance, equipment maintenance, and home appliance overhaul.

Installation

Marche/Arrêt

To power on the ET13S, press and hold the power button for 2 seconds. The device will boot up and display the main interface. To power off, press and hold the power button again for 2 seconds.

Chargement

The ET13S features a built-in 3.7V 1000mAh lithium battery. Connect the device to a USB power source using the provided USB Type-C cable for charging. The charging port is located under the stand on the rear of the device.

Paramètres de langue

Access the system settings via the touchscreen to select your preferred display language (Chinese or English).

Emissivity Settings

For accurate thermal measurements, adjust the emissivity setting in the thermal imager menu. The default value is 0.95, but it can be tuned from 0.1 to 0.99 depending on the material being measured. Refer to the emissivity table in the appendix for common materials.

Fusion Alignment

To enhance the precision of image overlap between thermal and visual images, perform fusion alignment calibration through the device settings.

Irfora ET13S front and back view
Devant et derrière views of the Irfora ET13S, highlighting the display, control buttons, and rear camera/sensor module.
Irfora ET13S touchscreen settings interface
A close-up of the ET13S touchscreen displaying system settings, including options for power boot mode, auto-off time, language selection, and setup time.
An instructional video demonstrating the power on/off, mode switching, multimeter functions (voltage, current, resistance, diode, continuity, capacitance), data hold, relative value measurement, and thermal imaging features of a similar ZT-R01 thermal imaging multimeter.

Opérationnel

Changement de mode

To switch between multimeter mode and thermal imaging mode, long-press the IR/DMM key. The device will toggle between the two main operating modes.

Fonctions du multimètre

Thermal Imager Functions

Image Capture and Data Transfer

Irfora ET13S IR-Camera Multimeter features
An image highlighting the key features of the ET13S IR-Camera Multimeter, including its multimeter function, thermal imaging, touchscreen, hotspot tracking, PC analysis, and 5 color palettes.
Irfora ET13S thermal imager color palettes
An image demonstrating the five available color palettes for the thermal imager: Iron Red, Rainbow, Fusion, White Heat, and White Heat Highlights, showing how they visualize temperature differences.
Une courte vidéo de démonstration montreasing the thermal imaging capabilities and multimeter functions of the SH7 thermal imager multimeter, including a hand scan, electrical panel check, and component temperature analysis.

Entretien

Gestion de la batterie

The built-in 3.7V 1000mAh lithium battery supports USB charging. The device features automatic screen shutdown and automatic power-off functions to effectively prolong battery life. These settings can be configured in the system settings menu.

Luminosité de l'écran

Adjust the screen brightness through the system settings to optimize visibility and conserve battery power.

Réinitialisation d'usine

If you encounter persistent issues or wish to clear all custom settings, you can restore the device to factory settings via the system settings menu.

Dépannage

L'appareil ne s'allume pas

Ensure the battery is sufficiently charged. Connect the device to a USB power source and allow it to charge for at least 30 minutes before attempting to power on again. If the issue persists, contact customer support.

Lectures de température inexactes

Verify the emissivity setting is correct for the material being measured. Adjust it in the thermal imager menu if necessary. Ensure the lens is clean and free from obstructions.

Multimeter measurements are incorrect

Check that the test leads are properly connected to the correct ports (COM and V/mA/A) for the desired measurement type. Ensure the correct measurement mode (DC/AC voltage, resistance, etc.) is selected. If measuring current, confirm the appropriate current port is used.

Cannot transfer data to PC

Ensure the USB Type-C cable is securely connected to both the device and the computer. Verify that the device's USB communication setting is enabled in the system settings. Try using a different USB port or cable on your computer.

Caractéristiques

FonctionnalitéDétail
Dimensions du produit7.28 x 6.3 x 1.57 pouces
Poids de l'article10.8 onces
Résolution IR192 x 192 pixels
Plage de mesure de la température-20℃ à 550℃ (-4°F à 1022°F)
Compteur multimètre10,000 comptes
Taille de l'écranÉcran tactile de 2.8 pouces
BatterieBatterie au lithium intégrée de 3.7 V 1000 mAh
Source d'énergieAlimenté par batterie
Résolution d'image affichée320x240
Domaine de View (FoV)50.0°(H) × 50°(V) / 72.1°(D)
Émissivité0.1-0.99 (0.95 par défaut)
Erreur de mesure de température±2℃ ou ±2%
Précision de l'affichage de la température0.1℃ / 0.1°F
DC Highest Input Voltage1000V
AC Highest Input Voltage750V
Irfora ET13S thermal pixel comparison
A comparison of thermal pixel resolutions between ET13S (192x192 IR Resolution) and ET12S (90x120 IR Resolution), showing the enhanced clarity of the ET13S.

Garantie et assistance

For any warranty claims or technical support, please refer to the product packaging or contact Irfora customer service directly. Keep your purchase receipt for warranty validation.

Documents connexes - ET13S

Préview ET13S Thermal Imaging Multimeter User Manual
Quick start user manual for the TOOLTOP ET13S Thermal Imaging Multimeter, covering safety instructions, technical features, operation, system settings, and technical specifications.