BDPQKPDV GYM8 SP Circuit Breaker C Curve 10A

BDPQKPDV GYM8 SP Circuit Breaker C Curve 10A User Manual

Model: GYM8 SP Circuit Breaker C Curve 10A

1. Introduction

This manual provides essential information for the safe and effective installation, operation, and maintenance of the BDPQKPDV GYM8 Single Pole (SP) Miniature Circuit Breaker (MCB) with a C Curve characteristic and 10A rating. Please read this manual thoroughly before installation and retain it for future reference. This device is designed to protect electrical circuits from overcurrents, which can result from overload or short circuit.

Devant view of the GYM8 SP Circuit Breaker

Illustration 1.1 : Avant view of the GYM8 SP Circuit Breaker, showing the ON/OFF switch and rating labels.

2. Consignes de sécurité

AVERTISSEMENT : Risque de choc électrique. L’installation et la maintenance doivent être effectuées uniquement par du personnel qualifié.

3. Produit terminéview

The BDPQKPDV GYM8 SP Circuit Breaker is a single-pole miniature circuit breaker designed for DIN rail mounting. It provides reliable protection against overloads and short circuits in AC electrical systems.

3.1 Principales caractéristiques

face avant inclinée view of the GYM8 SP Circuit Breaker

Image 3.1 : Vue de face en biais view of the circuit breaker, highlighting its compact design.

4. Spécifications

AttributValeur
MarqueBDPQKPDV
ModèleGYM8 SP Circuit Breaker C Curve 10A
Courant nominal10A
Vol évaluétage220V (CA)
Polonais1 (Single Pole)
Tripping CurveCourbe C
MatérielCuivre (composants internes)
Dimensions du colis1.18 x 0.79 x 0.39 pouces
Poids de l'article1.76 onces
Type de montageRail DIN
Mounting and dimension diagram for the GYM8 SP Circuit Breaker

Image 4.1: Detailed mounting and dimension diagram, showing measurements in millimeters.

5. Configuration et installation

Proper installation is critical for the safe and reliable operation of the circuit breaker. Ensure all power is OFF before proceeding.

5.1 Outils requis

5.2 étapes d'installation

  1. Coupure de courant : Locate the main electrical panel and turn off the main power supply to the circuit where the breaker will be installed. Verify with a multimeter that the power is off.
  2. Montage sur rail DIN :
    • Position the circuit breaker on the DIN rail.
    • Engage the top clip of the breaker onto the top edge of the DIN rail.
    • Press the bottom of the breaker firmly until it clicks into place on the DIN rail. Refer to Image 5.1 for visual guidance on the mounting mechanism.
  3. Connexions de câblage :
    • Strip approximately 10-12mm of insulation from the circuit wires.
    • Connect the incoming live wire to the top terminal of the circuit breaker.
    • Connect the outgoing live wire (to the load) to the bottom terminal of the circuit breaker.
    • Ensure all terminal screws are tightened securely to prevent loose connections, which can cause overheating.
  4. Vérification: Vérifiez que toutes les connexions sont bien serrées et que la polarité est correcte. Assurez-vous qu'aucun fil n'est dénudé.
  5. Restaurer l'alimentation : Once installation is complete and verified, restore power at the main supply.
Dos view of the GYM8 SP Circuit Breaker showing DIN rail mounting mechanism

Image 5.1 : Dos view of the circuit breaker, illustrating the DIN rail mounting clips and release mechanism.

6. Mode d'emploi

The GYM8 SP Circuit Breaker is designed for simple operation.

6.1 Mise en marche du disjoncteur

6.2 Coupure du disjoncteur

6.3 Automatic Tripping

In the event of an overload or short circuit, the circuit breaker will automatically trip to the "OFF" position, protecting the circuit. The lever will typically rest in a middle or fully down position, indicating a trip. Before resetting, identify and rectify the cause of the trip.

7. Entretien

The GYM8 SP Circuit Breaker requires minimal maintenance. Regular inspections are recommended to ensure continued safe operation.

8. Dépannage

ProblèmeCause possibleSolution
Le disjoncteur se déclenche fréquemment.Overload on the circuit, short circuit, faulty appliance, or incorrect breaker rating.Reduce load on the circuit, inspect appliances for faults, check wiring for short circuits, or verify breaker rating is appropriate for the load. Consult a qualified electrician.
Le disjoncteur ne se réarme pas.Persistent fault (overload or short circuit) still present, or internal damage to the breaker.Ensure the fault has been cleared. If the breaker still does not reset, it may be damaged and require replacement. Do not force the lever.
Le disjoncteur est chaud au toucher.Loose connections, excessive current draw, or internal fault.Immediately disconnect power. Check all wiring connections for tightness. Reduce load. If the issue persists, replace the breaker. Consult a qualified electrician.

9. Garantie et assistance

For warranty information and technical support regarding your BDPQKPDV GYM8 SP Circuit Breaker, please refer to the documentation provided at the point of purchase or contact your retailer. Keep your purchase receipt as proof of purchase.

Pour obtenir de l'aide supplémentaire, vous pouvez consulter le site web du fabricant. webConsultez leur site web ou contactez leur service client. Les coordonnées se trouvent généralement sur l'emballage du produit ou sur le site du détaillant. website.

Documents connexes - GYM8 SP Circuit Breaker C Curve 10A

Préview NHP DIN-T DTM6320C Miniature Circuit Breaker (MCB) 6kA 3 Pole 20A C Curve Specifications
Detailed specifications and product information for the NHP DIN-T DTM6320C Miniature Circuit Breaker (MCB). Features include 6kA breaking capacity, 3 poles, 20A rated current, C trip curve, and dimensions.
Préview Schneider Electric A9F03110 iC60N-B10-1 Miniature Circuit Breaker Datasheet
Technical specifications and product characteristics for the Schneider Electric A9F03110 iC60N-B10-1 single-pole miniature circuit breaker. Includes details on electrical ratings, tripping characteristics, certifications, and environmental specifications.
Préview EARU Miniature Current Circuit Breaker Instruction Manual - Safety and Operation Guide
This instruction manual from EARU ELECTRIC provides essential safety information and operational guidance for Miniature Current Circuit Breakers (MCBs), including models like AFDD-63 and EAB6L, ensuring safe and optimal performance in low-voltage systèmes de distribution d'énergie.
Préview Hyundai Electric Circuit Breaker Technical Information: Cascading and Selectivity
This document provides detailed technical specifications for Hyundai Electric's HGM, HGE, HGP, and HGD series circuit breakers, focusing on the principles and application of cascading (filiación) and selectivity (discriminación) in electrical protection systems. It includes performance tables for breaking capacity and selectivity coordination.
Préview MEMSHIELD 2 Circuit Breakers: The Guide to Circuit Protection and Control
Comprehensive guide to MEMSHIELD 2 Miniature and Moulded Case Circuit Breakers, covering MCB operation, cable protection, discrimination, fault current calculation, DC applications, motor circuit protection, transformer protection, and thermal de-rating.
Préview Dispositifs de protection électrique Siemens : MCB, RCCB, MCCB, ACB - Produit surview et détails techniques
Complet surview Des dispositifs de protection de circuits Siemens SENTRON et SINOVA, notamment les disjoncteurs miniatures (MCB), les disjoncteurs différentiels (RCCB), les disjoncteurs boîtier moulé (MCCB) et les disjoncteurs à air (ACB). Détails des gammes de produits, spécifications techniques, applications et caractéristiques de sécurité.