1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of the Srutueo Tuya Smart ZigBee Energy Meter 80A. This device is designed to monitor electrical parameters such as KWh, voltage, current, and power consumption for both 110V and 240V systems. It integrates with the Tuya Smart or Smart Life application for remote monitoring and control.

2. Produit terminéview

The Srutueo Smart ZigBee Energy Meter consists of the main meter unit and an external Current Transformer (CT) clamp. The meter unit processes the data, while the CT clamp measures the current flowing through the monitored circuit.

Srutueo Tuya Smart ZigBee Energy Meter with CT Clamp

Figure 2.1 : Srutueo Tuya Smart ZigBee Energy Meter and Current Transformer (CT) Clamp. The meter unit has input terminals for L, N, S1, and S2, indicating connections for live, neutral, and the CT clamp.

Transformateur de courant (TC) Clamp

Figure 2.2 : Gros plan view of the Current Transformer (CT) Clamp. This component is designed to be clamped around a live wire to measure current non-invasively.

3. Spécifications

ParamètreValeur
Protocole de communicationZigBee
Compatibilité des applicationsTuya Smart, vie intelligente
Plage de mesure0.2-80A
Voltaget gamme100-240V AC
Plage de température ambiante-10°C à 50°C
Fréquence sans filWiFi 2.4Ghz (for ZigBee gateway connection)
MatérielPlastique
DimensionsEnviron 4.33 x 3.94 x 1.57 pouces
PoidsEnviron 4 onces

4. Configuration et installation

4.1 Précautions de sécurité

4.2 Schéma de câblage

Follow the diagram below for correct wiring. The meter requires a live (L) and neutral (N) connection for power. The CT clamp wires (S1, S2) connect to the corresponding terminals on the meter. The CT clamp should be installed around the live wire of the load you wish to monitor.

Wiring Diagram for Tuya Smart ZigBee Energy Meter

Figure 4.1 : Wiring diagram showing connections for the energy meter. The L and N terminals connect to the main power supply, and the S1/S2 terminals connect to the CT clamp, which encircles the live wire of the load.

  1. Connect the Live (L) wire from your power source to the 'L' terminal on the meter.
  2. Connect the Neutral (N) wire from your power source to the 'N' terminal on the meter.
  3. Connect the red wire of the CT clamp to the 'S1' terminal on the meter.
  4. Connect the black wire of the CT clamp to the 'S2' terminal on the meter.
  5. Ouvrez le CT clamp and place it around the live wire of the electrical load you intend to monitor. Ensure the clamp est bien fermé.

4.3 Installation et appairage de l'application

This device requires a ZigBee gateway (not included) and the Tuya Smart or Smart Life app for full functionality.

  1. Download the "Tuya Smart" or "Smart Life" app from your mobile device's app store (Google Play Store for Android, Apple App Store for iOS).
  2. Inscrivez-vous ou connectez-vous à votre compte.
  3. Assurez-vous que votre passerelle ZigBee est allumée et connectée à votre réseau Wi-Fi domestique.
  4. In the app, tap '+' to add a new device. Select "Add Device" and then choose the appropriate ZigBee device category (e.g., "Energy Meter" or "Sensor").
  5. Follow the on-screen instructions to put the energy meter into pairing mode (refer to the device's specific pairing button/procedure if available, typically a long press of a reset button).
  6. Once the device is discovered and added, you can rename it and assign it to a room.

5. Mode d'emploi

5.1 Suivi de la consommation d'énergie

Après un appairage réussi, vous pouvez view real-time and historical energy data through the Tuya Smart or Smart Life app.

App Screenshot: Energy Consumption Overview

Figure 5.1 : App interface displaying energy consumption overview, including daily average costs and usage over time.

App Screenshot: Real-time Voltage, Courant, Puissance

Figure 5.2 : App interface showing real-time readings for voltage, current, and power consumption of the monitored circuit.

5.2 Creating Smart Scenes (Automation)

The app allows you to create automated scenes based on the energy meter's readings, integrating with other smart devices.

App Screenshot: Create Scene Function

Figure 5.3 : App interface for creating smart scenes. This allows setting conditions (e.g., power exceeding a threshold) to trigger actions (e.g., turning off a smart breaker).

6. Entretien

The Srutueo Smart ZigBee Energy Meter is designed for low maintenance. Follow these guidelines to ensure optimal performance:

7. Dépannage

ProblèmeCause possibleSolution
Device not appearing in app / Cannot pair
  • Pas en mode appariement.
  • ZigBee gateway not connected or too far.
  • Incorrect app selected.
  • Ensure the device is in pairing mode (refer to device instructions for specific button press).
  • Verify ZigBee gateway is online and within range.
  • Use "Tuya Smart" or "Smart Life" app.
No data or incorrect readings in app
  • TC clamp not correctly installed.
  • Problèmes de câblage.
  • Appareil non alimenté.
  • Check if the CT clamp is securely closed around the live wire.
  • Verify all wiring connections (L, N, S1, S2) are correct and secure.
  • Ensure the meter unit is receiving power (100-240V AC).
L'application indique que l'appareil est hors ligne.
  • ZigBee gateway offline or disconnected.
  • Poor ZigBee signal.
  • Puissance outage au mètre.
  • Check the status of your ZigBee gateway and home Wi-Fi.
  • Relocate the gateway closer to the meter or use a ZigBee repeater.
  • Verify the meter is powered on.

8. Garantie et assistance

For warranty information or technical support, please contact the manufacturer, Srutueo, or your point of purchase. Keep your purchase receipt as proof of purchase.

Manufacturer: Srutueo

For further assistance, please visit the official Srutueo website ou contactez leur service client.

Documents connexes - Tuya Smart ZigBee Energy Meter 80A

Préview MatSee Plus ATMS1603 WiFi Smart Energy Meter - User Manual
User manual for the MatSee Plus ATMS1603 WiFi Smart Energy Meter. Monitor electricity consumption (KWh, Voltage, Current, Power) in real-time via the Smart Life App. Features DIN rail mounting, 63A rating, and 100-230VAC compatibility.
Préview UNI-T UT210E PRO Mini Clamp Manuel d'utilisation du compteur
Ce document fournit un manuel d'utilisation complet pour l'UNI-T UT210E PRO Mini Clamp Compteur, détaillant ses caractéristiques, précautions de sécurité, spécifications techniques et instructions de fonctionnement pour diverses mesures électriques.
Préview PC321-Z-TY Bloc d'alimentation monophasé/triphaséamp Guide de démarrage rapide
Get started with the EARU PC321-Z-TY Smart Power Clamp. This guide covers installation, configuration, and features for monitoring single/3-phase electricity usage with ZigBee connectivity and the Smart Life app.
Préview Triplett CM1000 1000A TRMS AC Clamp Manuel d'utilisation du compteur
Manuel d'utilisation complet du Triplett CM1000 1000A True RMS AC Clamp Compteur, couvrant les caractéristiques, le fonctionnement, la sécurité, les spécifications et la maintenance pour des mesures électriques précises.
Préview Klein Tools CL445 HVAC Clamp Meter Instruction Manual | Specifications & Operation
Comprehensive instruction manual for the Klein Tools CL445 HVAC Clamp Meter. Learn about its features, specifications, operating procedures, safety warnings, and maintenance.
Préview D52-2066 DIN-rail Multi-function Digital AC Meter User Guide
User guide and technical specifications for the D52-2066 DIN-rail multi-function digital AC meter. Covers voltage, current, power, energy, frequency, and power factor measurements, wiring, and specifications.