1. Introduction
The EPEVER IPT 3000-12 is a high-frequency pure sine wave inverter designed for converting 12V DC power to 230V AC power. It features a fully digital intelligent design with a dual closed-loop voltage and current control algorithm, ensuring fast response, high conversion efficiency, low total harmonic distortion (THD), and high operational reliability. This inverter is suitable for various off-grid DC-AC systems, including vehicle systems, security surveillance systems, emergency lighting, domestic electrical systems, and field electrical systems that require high-quality power.
Please read this manual thoroughly before installation and operation to ensure proper use and to prevent damage to the inverter or connected equipment.
2. Consignes de sécurité
Respectez les consignes de sécurité suivantes lors de l'installation et du fonctionnement :
- Veillez à installer l'onduleur dans un endroit bien ventilé, à l'écart des matériaux inflammables, de l'humidité et de la lumière directe du soleil.
- N’exposez pas l’onduleur à la pluie, à la neige, aux projections d’eau ou à tout autre liquide.
- Ensure all wiring connections are tight and correct to prevent loose connections that can cause overheating.
- Do not connect the inverter to an AC utility power source or generator.
- Débranchez toujours la batterie avant d'effectuer toute opération de maintenance ou de câblage.
- L'onduleur génère une tension élevéetage. Ne pas ouvrir le casinN’essayez pas de réparer l’appareil vous-même. Confiez toute réparation à un personnel qualifié.
- Tenez les enfants éloignés de l'onduleur.
- Use appropriate DC input cables and AC output cables with sufficient gauge for the power rating.
3. Produit terminéview
3.1 Principales caractéristiques
- Sortie d'onde sinusoïdale pure.
- Electrical isolation between input and output.
- Output power factor up to 1.
- Input protection: low voltage, survoltage.
- Output protection: overload, short circuit, over-temperature.
- RS485 communication port for remote monitoring.
- Remote ON/OFF control port (RJ11).
- High conversion efficiency and reliability.
- Low Total Harmonic Distortion (THD).
3.2 Identification des composants
Familiarize yourself with the main components of the EPEVER IPT 3000-12 inverter.

Figure 1 : Devant view of the EPEVER IPT 3000-12 Pure Sine Wave Inverter. This image shows the overall design of the inverter, highlighting its compact and robust casing.

Figure 2 : Front panel of the EPEVER IPT 3000-12 Inverter. This view details the AC output sockets, DC input terminals (red for positive, black for negative), the ON/OFF switch, and communication ports (REMOTE, RS-485). Status indicators for 'FAULT' and 'POWER' are also visible.

Figure 3 : Rear panel of the EPEVER IPT 3000-12 Inverter. This image displays the two integrated cooling fans, essential for maintaining optimal operating temperature and preventing overheating.
4. Configuration et installation
4.1 Environnement d'installation
- Install the inverter indoors, protected from direct sunlight, rain, and moisture.
- Ensure adequate airflow around the inverter for proper cooling. Maintain at least 15 cm (6 inches) of clear space around the unit.
- Avoid installing the inverter in areas with corrosive gases, excessive dust, or high humidity.
- Mount the inverter horizontally on a stable, non-flammable surface.
4.2 Connexions de câblage
Follow these steps for connecting the inverter to your battery bank and AC loads. Always ensure the inverter is switched OFF before making any connections.

Figure 4 : Wiring diagram illustrating the connection of 12V batteries. It also depicts how AC loads like mobile devices and lamps are connected to the inverter's AC output.

Figure 5 : System diagram showing the EPEVER IPT inverter integrated into a typical solar power system. This includes a solar charge controller, battery bank, and both DC and AC loads. The RS485 communication link to an MT75 remote meter is also shown.
4.2.1 Connexion de la batterie
- Connect the positive (+) terminal of the 12V battery bank to the red DC input terminal of the inverter.
- Connect the negative (-) terminal of the 12V battery bank to the black DC input terminal of the inverter.
- Ensure the battery cables are of appropriate gauge and length to minimize voltage goutte.
- Serrez bien toutes les connexions.
4.2.2 AC Load Connection
- Plug your AC appliances directly into the AC output sockets on the front panel of the inverter.
- Ensure the total power consumption of all connected AC loads does not exceed the inverter's continuous power rating (3000W).
- The inverter supports various AC outlet types, as shown in Figure 6.

Figure 6 : Illustration of different AC outlet configurations that can be supported by EPEVER inverters, demonstrating versatility for various regional standards.
4.2.3 Remote Control and Monitoring (Optional)
- Connect an external remote ON/OFF switch to the RJ11 port for convenient control.
- Utilize the RS485 communication port for remote monitoring with compatible EPEVER devices, such as the MT75 remote meter (see Figure 5).
5. Mode d'emploi
5.1 Mise en marche/arrêt de l'onduleur
- Pour allumer: After all connections are secure, switch the ON/OFF button on the inverter's front panel to the "ON" position. The "POWER" indicator should illuminate.
- Éteindre: Switch the ON/OFF button to the "OFF" position. The "POWER" indicator should turn off.
When using the remote ON/OFF switch, ensure the main switch on the inverter is in the "ON" position for the remote switch to function.
5.2 indicateurs d'état
- Indicateur d'ALIMENTATION : S'allume lorsque l'onduleur fonctionne normalement.
- Indicateur de défaut : Illuminates or flashes to indicate a fault condition (e.g., overload, over-temperature, low voltage). Refer to the Troubleshooting section for details.
6. Entretien
Regular maintenance ensures the longevity and optimal performance of your EPEVER IPT 3000-12 inverter.
- Nettoyage: Periodically clean the exterior of the inverter with a dry cloth. Ensure the cooling vents and fans (Figure 3) are free from dust and debris to maintain proper airflow.
- Relations: Regularly check all wiring connections (DC input, AC output) to ensure they are tight and free from corrosion. Loose connections can cause overheating and damage.
- Environnement: Verify that the installation environment remains within recommended conditions (temperature, humidity, ventilation).
- État de la batterie : Monitor the health of your battery bank, as poor battery performance can affect inverter operation.
N'essayez pas d'ouvrir l'onduleur casing for internal cleaning or repairs. This should only be done by authorized service personnel.
7. Dépannage
If the inverter is not functioning correctly, refer to the following table for common issues and their solutions.
| Problème | Cause possible | Solution |
|---|---|---|
| No AC output, POWER indicator OFF. | Inverter is OFF; Low battery voltage; Loose DC connections. | Turn ON the inverter; Charge or replace battery; Check and tighten DC connections. |
| FAULT indicator ON/flashing. | Overload; Over-temperature; Short circuit; Input overvoltage/sousvoltage. | Reduce AC load; Ensure proper ventilation, allow cooling; Check AC wiring for shorts; Verify battery voltage is within range (10.8-16VDC). |
| Faible volume de sortie CAtage or unstable output. | Vol batterietage too low; Excessive load; Poor DC connections. | Charge battery; Reduce load; Check and tighten DC connections. |
| L'onduleur émet un bruit inhabituel. | Overload; Fan obstruction. | Reduce AC load; Clean cooling fans and vents. |
If the problem persists after attempting these solutions, contact EPEVER customer support or your local dealer.
8. Spécifications
Technical specifications for the EPEVER IPT 3000-12 Pure Sine Wave Inverter:
| Paramètre | Valeur |
|---|---|
| Modèle | IPT3000-12 |
| Vol d'entrée nominaltage | 12 VCC |
| Vol d'entréetaget gamme | 10.8 ~ 16 VCC |
| Volume de sortietage | 220 V AC (±3%) / 230 V AC (-7% ~ +3%) |
| Puissance continue | 3000 W (Power Factor: 1) |
| Surtension | 6000 W @ 5S |
| Nominal Output Efficiency | > 87% |
| Max. Output Efficiency (30% load) | > 94% |
| Facteur de puissance de charge | 0.2 ~ 1 (Load power ≤ Continuous power) |
| Type de batterie | Lithium-ion / Lead-acid |
| Port de communication | RS485 (5VDC/200mA), RJ11 for remote ON/OFF |
| Dimensions (L x l x H) | 55.7 x 22.8 x 11.8 cm (21.9 x 9.0 x 4.6 pouces) |
| Poids | 9.5 kg (20.9 lb) |
| Certifications | EN/IEC62109-1/2, EN61000-6-2/4, FCC |
9. Garantie et assistance
9.1 Informations sur la garantie
The EPEVER IPT 3000-12 Pure Sine Wave Inverter comes with a Garantie constructeur d'un an from the date of purchase. This warranty covers defects in materials and workmanship under normal use. It does not cover damage caused by improper installation, misuse, accidents, unauthorized modifications, or natural disasters. Please retain your proof of purchase for warranty claims.
9.2 Assistance clientèle
For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact your authorized EPEVER dealer or visit the official EPEVER website de ressources d'assistance.
EPEVER Official Website: www.epever.com