1. Produit terminéview
The ProCom Heating ML250TPA-B is a 25,000 BTU Liquid Propane Ventless Infrared Plaque Heater designed to provide efficient heating for indoor spaces up to 1150 sq. ft. This heater features a thermostat control for adjustable heat settings and can be used with included base feet for floor placement or mounted on a wall.

Illustration 1.1 : Avant view of the ProCom ML250TPA-B heater with base feet.
Caractéristiques principales :
- 25,000 BTU Output: Heats areas up to 1150 sq. ft.
- Conception sans ventilation : No chimney or flue required.
- Infrared Plaque Heating: Provides radiant heat.
- Contrôle du thermostat : High/Medium/Low settings for precise temperature management.
- Push Button Ignition: For easy startup.
- Capteur d'épuisement de l'oxygène (ODS) : Automatically shuts off the heater if oxygen levels drop.
- Installation flexible : Includes base feet for floor standing and hardware for wall mounting.
- Aucune électricité requise : Operates independently of electrical power, ideal for outaget.
2. Consignes de sécurité
AVERTISSEMENT : Une installation, un réglage, une modification, une réparation ou un entretien inappropriés peuvent entraîner des dommages matériels, des blessures ou la mort. Lisez attentivement les instructions d'installation, d'utilisation et d'entretien avant d'installer ou d'entretenir cet équipement.
- This is a ventless appliance. It uses air from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided.
- Always ensure proper ventilation when operating this heater. Consider using a carbon monoxide detector for added safety.
- Ne stockez pas et n’utilisez pas d’essence ou d’autres vapeurs et liquides inflammables à proximité de cet appareil ou de tout autre appareil.
- Veillez à ce que la zone autour du radiateur soit dégagée et exempte de matériaux combustibles, d'essence et d'autres vapeurs et liquides inflammables.
- Never operate the heater in an area where it may be exposed to water.
- The Oxygen Depletion Sensor (ODS) is a safety feature that will shut off the heater if oxygen levels in the room become too low. Do not tamper with or bypass this safety device.
- Ensure the heater is installed on a level, stable surface if using base feet, or securely mounted to a wall according to instructions.
- Keep children and pets away from the heater, especially during operation, as surfaces can become very hot.
3. Configuration et installation
3.1 Déballage et inspection
Carefully remove the heater from its packaging. Inspect the unit for any shipping damage. If any damage is found, do not attempt to install or operate the heater. Contact your retailer or ProCom customer service immediately.
3.2 Choisir un emplacement
Select a location that is clear of combustible materials. Ensure adequate clearance from walls and furniture as specified in the full manual. This heater is designed for indoor use only.
3.3 Assembly (Base Feet or Wall Mount)
The heater comes with both base feet for floor placement and hardware for wall mounting. Choose the installation method that best suits your needs.

Image 3.1: The heater package includes base feet and a wall bracket for flexible installation.
- For Floor Standing: Attach the provided base feet to the bottom of the heater using the supplied screws. Ensure the heater is stable and level.
- Pour le montage mural : Use the included wall bracket and hardware to securely mount the heater to a suitable wall surface. Follow the detailed instructions in the complete manual for proper wall mounting to ensure stability and safety.

Image 3.2 : Example of the ProCom ML250TPA-B heater installed on a wall.
3.4 Propane Gas Connection
This heater operates on Liquid Propane (LP) gas. Connection to the LP supply must be performed by a qualified service person in accordance with local codes and ordinances. The heater does not require electricity for operation.
- A 3/8" Flare x 3/8" NPT Male brass 90-degree elbow and a 12 FT Propane Regulator Hose with a female flare nut end may be required for connecting to a 20 lb propane tank, especially if using the base feet to ensure proper clearance and prevent kinking of the hose.
- Ensure all connections are tight and leak-free. Perform a leak test with a soap solution before initial operation.
4. Mode d'emploi
4.1 Panneau de configuration terminéview

Image 4.1: The control panel features a Piezo Ignition button and a thermostat knob with variable heat settings.
The heater features a simple control panel with a Piezo Ignition button and a thermostat control knob. The thermostat knob allows you to select heat settings from "OFF PILOT" to various heat levels (e.g., 1-5 or High/Medium/Low).
4.2 Initial Startup Procedure
IMPORTANT: For the very first use, or after the heater has been disconnected from the propane supply for an extended period, the initial ignition may take longer than usual. This is normal as air needs to be purged from the gas lines.
- Ensure the propane supply valve is fully open.
- Turn the thermostat control knob to the "PILOT" position.
- Press and hold the thermostat control knob down firmly.
- While holding the knob down, repeatedly press the Piezo Ignition button until the pilot flame ignites. You may need to hold the knob down for several minutes (up to 10 minutes for the very first startup) to allow gas to reach the pilot.
- Once the pilot flame is lit, continue to hold the thermostat control knob down for approximately 30-60 seconds to allow the thermocouple to heat up and hold the pilot flame.
- Release the knob. If the pilot flame extinguishes, repeat steps 3-5.
- Once the pilot flame is stable, turn the thermostat control knob to your desired heat setting (e.g., 3, 4, 5, or High/Medium/Low). The main burner will ignite.
NOTE: It is recommended to perform the first ignition outdoors or in a well-ventilated area, as a thin oil layer on internal components may burn off, causing a temporary odor or light smoke.
4.3 Réglage de la puissance de chauffe
Rotate the thermostat control knob to adjust the heat output. Higher numbers or "High" settings will provide more heat, while lower numbers or "Low" settings will reduce the heat output. The heater will cycle on and off to maintain the set temperature.
Video 4.2: A demonstration of the ProCom Natural Gas Ventless Infrared Plaque Heater, highlighting its features and operation. Note: This video shows a natural gas model, but the operational principles for ignition and thermostat control are similar for the propane model.
5. Entretien
Regular maintenance ensures the safe and efficient operation of your ProCom heater. Always disconnect the heater from the propane supply and allow it to cool completely before performing any maintenance.
- Nettoyage: Gardez l'extérieur du radiateur propre. Utilisez un chiffon doux et sec.amp cloth to wipe down surfaces. Do not use abrasive cleaners or solvents. Ensure the air intake and exhaust vents are free from dust and debris.
- Inspection du pilote et du brûleur : Periodically inspect the pilot and main burner for any obstructions or unusual flame patterns. If the pilot flame appears weak or yellow, or if the main burner flames are not blue, contact a qualified service technician.
- Inspection des conduites de gaz : Regularly check the gas supply line and connections for any signs of wear, damage, or leaks.
- Stockage: If storing the heater for an extended period, disconnect it from the propane supply, clean it thoroughly, and store it in a dry, safe place.
6. Dépannage
Avant de contacter le service client, review Voici les problèmes courants et leurs solutions :
| Problème | Cause possible | Solution |
|---|---|---|
| Heater does not ignite or pilot light won't stay lit. |
|
|
| Heater produces an odor or light smoke on first use. | Protective oil coating burning off. | This is normal for initial operation. Ensure good ventilation. Odor/smoke should dissipate quickly. |
| Control knob does not function correctly at low settings (e.g., 1 or 2). | Possible manufacturing tolerance or design characteristic. | Ensure the knob is set to a position where the burner reliably ignites (e.g., 3 or higher). If persistent, contact customer support. |
| Heater makes a weird noise during ignition. | Intermittent ignition issue or gas flow problem. | Ensure gas supply is stable. If noise persists or ignition is unreliable, contact a qualified technician. |
7. Spécifications
| Marque | ProCom |
| Numéro de modèle | ML250TPA-B |
| Type de carburant | Propane liquide |
| Sortie en BTU | 25,000 XNUMX BTU |
| Couverture de chauffage | Jusqu'à 1150 pi.ca. |
| Dossier spécial | Overheat Protection, Oxygen Depletion Sensor (ODS) |
| Couleur | Blanc |
| Facteur de forme | Pedestal (with base feet) |
| Utilisation intérieure/extérieure | Intérieur |
| Dimensions du produit (P x L x H) | 8"P x 26.63"L x 23.5"H |
| Type de montage | Montage au sol, montage mural |
| Nombre de vitesses | 3 (High/Medium/Low thermostat settings) |
| Réglage de la température minimale | 40 degrés Fahrenheit |
| Poids de l'article | 34.6 livres |
| Code UPC | 848660008338 |
8. Garantie et assistance
For warranty information, please refer to the documentation included with your product or visit the official ProCom webIl est important de conserver votre preuve d'achat pour toute réclamation au titre de la garantie.
Note on Warranty Claims: Some warranty processes may require specific documentation, such as a professional pressure reading of your propane system, to validate claims. Please review the warranty terms carefully.
For technical assistance, replacement parts, or further inquiries, please contact ProCom customer service through their official channels.