Introduction
This manual provides essential information for the safe and efficient operation of your ProCom MN180TPA-B Natural Gas Ventless Infrared Plaque Heater. Please read all instructions carefully before installation, operation, or maintenance. Retain this manual for future reference.

Image : Avant view of the ProCom MN180TPA-B Natural Gas Ventless Infrared Plaque Heater, showcasing its compact design and infrared heating plaques.
Consignes de sécurité
Your ProCom heater is designed with safety in mind. It is a ventless unit, meaning it does not require an outside duct or chimney. However, proper ventilation is still crucial for safe operation. This heater is equipped with an Oxygen Depletion Sensor (ODS) that automatically shuts down the unit if oxygen levels become too low. It is ANSI Certified to ensure safety standards are met.
- Always ensure adequate air circulation in the room where the heater is operating.
- Do not obstruct the air intake or exhaust vents of the heater.
- Never use this heater in a recreational vehicle or boat.
- Gardez les matériaux inflammables à une distance de sécurité de l'appareil de chauffage.
- Regularly inspect the gas connections for leaks.
Caractéristiques du produit
- Infrared Heat Technology: Produces 18,000 Maximum BTU, heating up to 950 sq. ft.
- Conception sans ventilation : No outside duct or chimney required.
- Natural Gas Operation: Designed exclusively for natural gas fuel.
- Contrôle du thermostat : Allows setting to desired comfort level with High/Medium/Low settings.
- Piezo Ignition: Push-button ignition for easy startup, no electricity or batteries required.
- Capteur d'épuisement de l'oxygène (ODS) : Automatically shuts off the heater if oxygen levels drop.
- Installation polyvalente : Can be mounted on a wall or placed on the floor using included base feet.

Image: Diagram highlighting key features of the ProCom heater, including BTU output, ventless operation, natural gas compatibility, no electricity requirement, safety features, Piezo ignition, and thermostat mode.
Installation
The ProCom MN180TPA-B heater offers flexible installation options: wall-mounted or floor-standing.
Déballage et inspection
- Retirez soigneusement tous les matériaux d’emballage.
- Inspect the heater for any shipping damage. Do not install a damaged unit.
- Assurez-vous que tous les composants répertoriés dans la liste de colisage sont présents.
Choisir un emplacement
Select a location that allows for proper clearances from combustible materials. Ensure the area has adequate ventilation as per local codes and the heater's specifications.
Options d'installation
Debout au sol: Attach the included base feet to the bottom of the heater using the provided hardware. Ensure the heater is stable and level.
Montage mural : Use the included wall mounting bracket and hardware. Follow the detailed instructions in the manufacturer's full installation guide for secure wall attachment and proper clearances.

Image: Components included with the ProCom heater, showing the main unit, base feet, wall bracket, and highlighting the Oxygen Depletion Sensor and natural gas operation.

Image: The ProCom MN180TPA-B heater mounted on a wall in a living space, demonstrating its compact profile and integration into a room.
Raccordement au gaz
This heater operates on natural gas only. Connection to the natural gas supply must be performed by a qualified professional in accordance with all local codes and regulations. Ensure all connections are leak-tested before operation.
Mode d'emploi
Follow these steps to safely operate your ProCom MN180TPA-B heater.
Procédure d'allumage
- Assurez-vous que la vanne d'alimentation en gaz est ouverte.
- Turn the control knob to the 'PILOT' position.
- Press and hold the control knob in while simultaneously pressing the Piezo ignition button repeatedly until the pilot flame ignites.
- Continue to hold the control knob in for approximately 30-60 seconds after the pilot ignites to allow the thermocouple to heat up. Release the knob; the pilot should remain lit.
- If the pilot does not remain lit, repeat steps 2-4.
- Once the pilot is stable, turn the control knob to the desired heat setting (1-5). The main burner will ignite.
Contrôle du thermostat
The heater features a thermostat control with 5 variable heat settings. Rotate the control knob to select your preferred heat output. The heater will cycle on and off to maintain the set temperature.

Image : Gros plan view of the control panel on the ProCom heater, showing the Piezo ignitor button and the rotary knob for 5 variable heat settings and pilot control.
Éteindre le chauffage
- Tournez le bouton de commande sur la position « ARRÊT ».
- For prolonged shutdown, close the main gas supply valve to the heater.
Entretien
Un entretien régulier garantit la longévité et le bon fonctionnement de votre appareil de chauffage.
- Nettoyage: Assurez-vous que le radiateur soit complètement froid avant de le nettoyer. Utilisez un chiffon doux et sec.amp cloth to wipe down the exterior. Do not use abrasive cleaners.
- Inspection du pilote et du brûleur : Periodically inspect the pilot and burner ports for dust or debris. Clean gently with a soft brush if necessary.
- Connexions de gaz : Annually check all gas connections for tightness and signs of wear.
- Service professionnel: It is recommended to have the heater inspected by a qualified service technician at least once a year.
Dépannage
If you encounter issues with your heater, refer to the following common problems and solutions. For persistent issues, contact a qualified service technician.
| Problème | Cause possible | Solution |
|---|---|---|
| La veilleuse ne s'allume pas | No gas supply; Air in gas line; Pilot orifice clogged; Faulty thermocouple | Check gas supply; Purge air from line; Clean pilot orifice; Contact technician |
| Pilot lights but will not stay lit | Thermocouple not heating sufficiently; Loose thermocouple connection; Faulty ODS pilot assembly | Hold knob longer; Tighten connection; Contact technician |
| Main burner will not ignite | Pilot not lit; Main burner orifice clogged; Low gas pressure | Ensure pilot is lit; Clean burner orifice; Contact gas provider/technician |
| Heater cycles off frequently | Insufficient ventilation; ODS activation; Thermostat setting too high for room size | Increase ventilation; Check for obstructions; Adjust thermostat setting |
Caractéristiques
| Attribut | Détail |
|---|---|
| Marque | ProCom |
| Numéro de modèle | MN180TPA-B |
| Type de carburant | Gaz naturel |
| Puissance calorifique maximale (BTU) | 18,000 XNUMX BTU |
| Couverture de chauffage | Jusqu'à 950 pi.ca. |
| Type d'allumage | Push Button Piezo |
| Type de contrôle | Thermostat (High/Medium/Low) |
| Caractéristiques de sécurité | Capteur de déplétion d'oxygène (ODS) |
| Options de montage | Wall Mount, Floor Standing (Base Feet Included) |
| Dimensions du produit | 8"P x 22"L x 26"H |
| Poids de l'article | 26.2 livres |
| Couleur | Blanc |
| Certifications | CSA Certified, ANSI Certified |

Image: Diagram illustrating the dimensions of the ProCom MN180TPA-B heater: 24 inches H, 19 inches L, and 8 inches D.
Informations sur la garantie
For detailed warranty information regarding your ProCom MN180TPA-B Natural Gas Ventless Infrared Plaque Heater, please refer to the warranty card included with your product packaging or visit the official ProCom webLes conditions de garantie peuvent varier.
Assistance clientèle
If you require assistance, have questions about your heater, or need to report an issue, please contact ProCom customer support. Refer to your product packaging or the official ProCom webCe site contient les informations de contact les plus récentes, notamment les numéros de téléphone, les adresses électroniques et les ressources d'assistance en ligne.