1. Introduction

The OOYCYOO MPPT Solar Charge Controller 60A is an advanced device designed to manage power flow from your solar panels to your battery bank. It utilizes Maximum Power Point Tracking (MPPT) technology to optimize energy harvesting, ensuring efficient charging for 12V, 24V, 36V, and 48V battery systems. This controller automatically identifies the system voltage and is compatible with various battery types, including lead-acid and lithium.

OOYCYOO MPPT Solar Charge Controller 60A

Illustration 1.1 : Avant view of the OOYCYOO MPPT Solar Charge Controller 60A, showing the LCD display and control buttons.

2. caractéristiques du produit

OOYCYOO MPPT Solar Charge Controller 60A with labeled components and protection icons

Image 2.1 : Terminéview of the controller's features, including LCD display, terminals, and protection icons.

3. Safety Precautions and Protection Functions

To ensure safe operation and prevent damage, observe the following safety guidelines. The controller incorporates several protection mechanisms:

Branchez toujours d'abord la batterie, puis les panneaux solaires, et enfin la charge. Débranchez-les dans l'ordre inverse.

4. Configuration et installation

Suivez ces étapes pour installer correctement votre contrôleur de charge solaire MPPT :

  1. Montage: Choose a dry, well-ventilated location away from direct sunlight and heat sources. Ensure adequate space around the controller for air circulation.
  2. Connexion de la batterie : Connect the battery cables to the controller's battery terminals (labeled '+' and '-'). Ensure correct polarity. The controller will automatically detect the battery voltage. Use 10 AWG wires for power terminals.
  3. Connexion du panneau solaire : Connect the solar panel cables to the controller's PV input terminals (labeled 'SOLAR +' and '-'). Ensure correct polarity. Verify that the open circuit voltage (Voc) and power of your solar array do not exceed the controller's maximum limits for your system voltage.
  4. Connexion de chargement (facultatif) : Connect your DC load to the controller's load terminals (labeled 'LOAD +' and '-'). Ensure correct polarity.
Solar system connection diagram with OOYCYOO MPPT controller

Image 4.1: Diagram illustrating the connection of solar panels, battery, and DC load to the MPPT controller. It also shows support for parallel connection of two 60A controllers for a total of 120A.

Application scenario of OOYCYOO MPPT Solar Charge Controller in a home solar power system

Image 4.2 : Example of the MPPT Solar Charge Controller integrated into a residential solar power system, managing power for various household appliances.

Côté view of OOYCYOO MPPT Solar Charge Controller showing terminal connections

Image 4.3 : Côté view of the controller highlighting the solar, battery, and load terminals for wiring.

5. Mode d'emploi

Once connected, the controller will automatically begin operation. The LCD display provides real-time information:

Boutons de contrôle :

The controller features four buttons (A, B, C, D) and a SET button for navigation and parameter adjustment. Refer to the on-screen menu for specific functions. Pressing A+D for 5 seconds typically initiates a reset.

Fonctionnement du ventilateur de refroidissement :

The integrated cooling fan activates automatically when the internal temperature exceeds 45°C and deactivates when the temperature drops below 40°C, ensuring optimal performance and longevity.

6. Battery Charging Methods

The OOYCYOO MPPT controller employs a 4-stagalgorithme de charge pour optimiser la santé et la durée de vie de la batterie :

Pre-set charging parameters are available for sealed, gel, flooded lead-acid, and LFP (lithium iron phosphate) batteries. Users can also customize charging parameters to suit other battery types or specific requirements.

7. Spécifications

ParamètreValeur
Courant de charge nominal60A
Vol systèmetage12V/24V/36V/48V Automatique
Max. Volume de circuit ouvert PVtage VOC)160 V CC
Puissance d'entrée PV maximale (système 12 V)720W (Voc ≤ 72V)
Puissance d'entrée PV maximale (système 24 V)1440W (Voc ≤ 108V)
Puissance d'entrée PV maximale (système 36 V)2100W (Voc ≤ 160V)
Puissance d'entrée PV maximale (système 48 V)2800W (Voc ≤ 160V)
Power Terminal Wire Size10 AWG
Température de fonctionnement40°C (as per specification 4E+1 Degrees Celsius)
Dimensions (paquet)35.9 x 15.2 x 6.9 cm
Poids (colis)1.85 kg
MatérielPlastique
Type d'affichageÉcran LCD
Code UPC768420064490
Table of battery parameters and PV module series connection guidelines

Image 7.1: Detailed table showing original battery parameters for 12V, 24V, and 48V systems, including float voltage, sous-voltage protection, and maximum PV input power. Also includes PV module series connection guidelines.

Internal components of OOYCYOO MPPT Solar Charge Controller, showing copper coil transformer and capacitance

Image 7.2: View of the internal components, highlighting the copper coil transformer and capacitance, which contribute to the controller's efficiency and stability.

8. Dépannage

If you encounter issues with your OOYCYOO MPPT Solar Charge Controller, consider the following general troubleshooting steps:

Pour les problèmes persistants, contactez le service client.

9. Entretien

Un entretien régulier contribue à assurer la longévité et les performances optimales de votre régulateur de charge solaire :

10. Garantie et assistance

For warranty information, please refer to the documentation provided with your purchase or contact your retailer. For technical support or further assistance, please contact OOYCYOO customer service.

You may also find additional resources by scanning the QR code on the product label or visiting the following link: http://qr61.cn/oQXA1T/qsECN8rL

Documents connexes - EC 60A

Préview Manuel d'utilisation du contrôleur du système de production d'énergie solaire OOYCYOO MPPT
Ce document fournit des instructions complètes et les spécifications techniques du contrôleur de système de production d'énergie solaire MPPT OOYCYOO. Découvrez comment l'installer, paramétrer les fonctions, utiliser les protections et câbler le système pour une utilisation optimale de l'énergie solaire.
Préview Manuel d'utilisation du régulateur de charge solaire Ooycyoo MPPT série 'P' 40A/60A
Découvrez le régulateur de charge solaire Ooycyoo MPPT série « P » 40 A/60 A. Ce manuel d’utilisation détaille la technologie MPPT avancée et des fonctionnalités telles que l’affichage en temps réel, le chargement USB et la gestion de plusieurs sources de courant.tage recharge de batterie, ainsi que des conseils essentiels de sécurité et d'installation pour les systèmes d'énergie solaire.
Préview PowMr Solar Charge Controller Troubleshooting Guide
A concise troubleshooting guide for PowMr MPPT solar charge controllers, addressing common issues like no display, power-on problems, voltage discrepancies, and charging failures. Includes step-by-step solutions and contact information for warranty support.
Préview Guide de câblage et de réglage du contrôleur de charge solaire MPPT série Y&H SY
Guide complet du câblage et de la configuration du régulateur de charge solaire MPPT Y&H série SY, couvrant le raccordement de la batterie, du panneau solaire, de la charge et du volume.tage réglages pour différents types de batteries.
Préview Manuel d'utilisation du contrôleur de charge solaire MPPT
User manual for the 60A MPPT Solar Charge Controller, detailing features, installation, operation, settings, and technical specifications for efficient solar energy management.
Préview Manuel d'utilisation du contrôleur de charge solaire MPPT PowMr POW-M60-PRO
Ce manuel d'utilisation fournit des instructions complètes pour le contrôleur de charge solaire MPPT PowMr POW-M60-PRO, couvrant les consignes de sécurité, les procédures d'installation, les modes de fonctionnement, les caractéristiques de charge, les fonctions de protection, le dépannage et les spécifications techniques détaillées pour une gestion optimale du système d'énergie solaire.