Frigga M1E

Frigga M1E Single Use Temperature Data Logger with External Probe User Manual

Model: M1E | Brand: Frigga

1. Introduction

This manual provides instructions for the proper use and maintenance of the Frigga M1E Single Use Temperature Data Logger with External Probe. This device is designed for accurate temperature monitoring in various applications, particularly within cold chain logistics, medicine storage, and food refrigeration. It records temperature data and generates PDF and CSV reports without requiring special software.

2. Produit terminéview

The Frigga M1E data logger is a compact, single-use device equipped with an external probe for precise temperature measurement. It features an LCD screen for real-time data display and buttons for operation.

Frigga M1E Single Use Data Logger with labeled components

Image 2.1: Frigga M1E Single Use Data Logger with its key components labeled, including the USB Cover, USB Connector, LED Indicator, LCD Screen, Stop Button, Start Button, Bar Code Label, and External Sensor.

Composants clés :

3. Installation

The Frigga M1E data logger is designed for immediate use. No prior setup or charging is required as it comes with a pre-installed, long-lasting CR2450 battery.

  1. Déballez l'appareil : Carefully remove the data logger from its packaging.
  2. Sonde externe : Ensure the external temperature probe is securely connected to the device. The probe is essential for accurate temperature measurement.
  3. Placement: Position the data logger and its external probe in the environment where temperature monitoring is required. Ensure the probe is placed to accurately reflect the temperature of the monitored items.

4. Mode d'emploi

4.1 Démarrage de l'enregistreur de données

To begin temperature recording:

Frigga M1E User-friendly Interface showing start and stop instructions

Image 4.1: Visual guide for starting and stopping the Frigga M1E data logger, illustrating the button presses and LED feedback.

4.2 Stopping the Data Logger

To stop temperature recording:

4.3 Work Status Indicators

The LCD screen provides various status indicators:

Frigga M1E Work Status Instruction display modes

Image 4.2: Display modes of the Frigga M1E data logger, including Sleep Mode, Start Delay, Recording Mode, Generating Report, and Stop Mode.

4.4 Retrieving Data Reports

After recording is complete, you can easily retrieve the data:

  1. Remove the USB cover.
  2. Plug the data logger into a standard USB port on any computer.
  3. The device will automatically generate a PDF and CSV report. These files apparaîtra comme un lecteur amovible.
  4. Open the PDF report to view a summary, temperature graph, and detailed data table. The CSV file provides raw data for further analysis.
Frigga M1E Auto PDF Report Plug and Play feature

Image 4.3: Illustration of the Frigga M1E's plug-and-play functionality for generating PDF and CSV reports directly from the device when connected to a computer.

Vidéo 4.1: This video demonstrates the physical components of the Frigga M1E data logger, how to initiate recording by pressing the START button, how to stop recording using the STOP button, and the process of plugging the device into a computer to automatically generate and access PDF and CSV data reports.

5. Caractéristiques

The Frigga M1E data logger offers several features designed for reliable temperature monitoring:

Frigga M1E data logger highlighting its features

Image 5.1: Un plusview of the Frigga M1E's capabilities, including data analysis, temperature calibration report, IP65 waterproof rating, LED alarm, temperature unit switch, event mark, and zero data loss.

Frigga M1E with CR2450 battery compared to CR2032, illustrating long battery life

Image 5.2: This image highlights the long-lasting battery life of the Frigga M1E, featuring a CR2450 battery.

6. Spécifications

Frigga M1E Product Parameter details

Image 6.1: Detailed product parameters for the Frigga M1E, including measurement range, accuracy range, and memory capacity.

Frigga M1E Data Logger Specifications
ParamètreDétail
Nom du modèleM1E
Plage de mesure-40°C à 80°C (-40°F à 176°F)
Plage de précision±0.5℃ (-20℃ to +40℃); ±1℃ for other ranges
Capacité de mémoire14400 XNUMX lectures
RéutilisabilitéUsage unique
Source d'énergie1 Lithium Ion CR2450 battery (included)
Technologie de connectivitéUSB
Type d'affichageÉcran LCD
Caractéristiques spécialesAlarm, Fast Reading System, High Accuracy, External Probe
Matériau extérieurPlastique
Instructions d'entretien du produitEssuyer propre
Poids de l'article11.2 onces
Longueur de l'article4 pouces
Utilisation intérieure/extérieureIntérieur

7. Entretien

The Frigga M1E is a single-use device and requires minimal maintenance. Follow these guidelines:

8. Dépannage

If you encounter issues with your Frigga M1E data logger, consider the following:

For further assistance, please contact Frigga customer support.

9. Garantie et assistance

Frigga products are manufactured to high-quality standards. For specific warranty information, please refer to the documentation included with your purchase or visit the official Frigga website. For technical support, troubleshooting assistance, or any inquiries regarding your Frigga M1E data logger, please contact Frigga customer service through their official channels.

Vous trouverez plus d'informations et les coordonnées sur le Frigga Brand Store on Amazon ou du fabricant website.

Documents connexes - M1E

Préview Frigga T7 Series User Manual - Real-Time Cold Chain Temperature Monitoring
Comprehensive user manual for the Frigga T7 Series temperature data logger. Covers device appearance, display functions, setup, monitoring, stopping, reporting, and important cautions for cold chain logistics.
Préview Manuel d'utilisation de l'enregistreur de données de température et d'humidité FRIGGA V5
Manuel d'utilisation de l'enregistreur de données de température et d'humidité FRIGGA V5, détaillant ses caractéristiques, son fonctionnement, sa configuration et ses fonctions de rapport pour la logistique de la chaîne du froid.
Préview Manuel d'utilisation du centre de données Frigga V 1.0.0
Manuel d'utilisation complet du logiciel Frigga Data Center, guidant les utilisateurs à travers l'installation, la gestion des données, la configuration des appareils, les services cloud et les fonctionnalités de conformité pour la surveillance de la chaîne du froid.
Préview Manuel d'utilisation de l'enregistreur de données de température et d'humidité FRIGGA série V5 Plus
Manuel d'utilisation complet de l'enregistreur de données de température et d'humidité FRIGGA V5 Plus. Découvrez comment configurer, utiliser et récupérer les données de votre enregistreur pour la surveillance de la chaîne du froid.
Préview Manuel d'utilisation du multicapteur temps réel Frigga 4G et Wi-Fi 6
Manuel d'utilisation du multicapteur en temps réel Frigga 4G et Wi-Fi 6 (modèle S0), détaillant ses caractéristiques, le contenu de l'emballage, le produitview, instructions d'installation, guide des indicateurs LED, spécifications techniques, placement de l'appareil, informations sur la batterie, étapes de dépannage et conformité FCC.
Préview Frigga SV2 Series Smart Active Data Logger User Manual
User manual for the Frigga SV2 Series Smart Active Data Logger, detailing appearance, display functions, operation steps, usage scenarios, and FCC compliance.