The LFF CO2 Detector Model LAQ962 is an advanced indoor air quality monitor designed to provide real-time measurements of carbon dioxide (CO2) concentration, ambient temperature, and relative humidity. Utilizing Non-Dispersive Infrared (NDIR) technology, this device ensures accurate data for effective environmental monitoring. It features a large, clear color display, customizable dual alarms, and a built-in rechargeable battery for portable use.
Caractéristiques principales :
- Surveillance multifonctionnelle : Measures CO2 concentration, temperature, and humidity.
- NDIR Technology: Ensures high accuracy for CO2 readings.
- Alarmes doubles personnalisables : Set specific CO2 thresholds for audible alerts.
- CO2 Concentration Indicator: Visual display of Normal, Warning, and Dangerous CO2 levels.
- Grand écran couleur : 4-inch LCD screen for easy readability.
- Batterie rechargeable : Batterie intégrée de 2000 mAh pour une utilisation prolongée.
- Rétroéclairage réglable : Three levels of brightness for optimal viewing.

2. Contenu du colis
Veuillez vérifier que tous les articles sont présents et en bon état à l'ouverture du colis :
- LFF CO2 Detector (Model LAQ962)
- Câble de charge de type C
- Manuel de l'utilisateur (ce document)
3. Installation et utilisation initiale
3.1 Chargement de l'appareil
Before first use, fully charge the LFF CO2 Detector. Connect the provided Type-C charging cable to the device's charging port and plug the other end into a standard USB power adapter (not included) or a computer USB port. The battery indicator on the display will show charging status.

3.2 Mise sous/hors tension
Press and hold the power button (location typically on the side or back) for a few seconds to turn the device on or off. The display will illuminate upon successful power-on.
4. Fonctionnement
4.1 Affichage terminéview
The large color display provides a comprehensive view of current air quality parameters:
- CO2 Concentration (PPM): Central large number, indicating parts per million.
- Température: Displayed in Fahrenheit or Celsius.
- Humidité: Affiché en pourcentagetage.
- Temps: Heure actuelle.
- Statut d'alarme : Icônes indiquant les alarmes actives.
- Indicateur de batterie : Affiche la durée de vie restante de la batterie.

4.2 Understanding CO2 Levels
The device categorizes CO2 concentration into three stages, indicated by color changes on the display and corresponding icons:
- Normale Stage: CO2 ≤ 800 ppm (Green indicator). Indicates good air quality.
- Avertissement Stage: CO2 801 - 1600 ppm (Yellow indicator). Suggests ventilation may be required.
- Dangereux Stage: CO2 > 1600 ppm (Red indicator). Indicates poor air quality; immediate ventilation is recommended.

4.3 Réglage des alarmes
The LFF CO2 Detector features customizable dual alarms. When the measured CO2 level reaches your set high or low alarm threshold, an audible beep will sound, and the alarm icon will flash. Refer to the device's on-screen menu or specific buttons (usually labeled 'SET' or 'MODE') to adjust the CO2 alarm values.

4.4 Réglage du rétroéclairage
The device offers three levels of backlight brightness (100%, 50%, 0%) to suit different lighting conditions and conserve battery life. Use the designated button (often indicated by a light bulb icon) to cycle through the brightness settings.

4.5 Réglage de l'heure et de la date
To set the current time and date, navigate through the device's menu using the control buttons. Follow the on-screen prompts to adjust hours, minutes, and date. Consult the quick start guide or on-screen instructions for specific button sequences.
5. Entretien
5.1 Nettoyage
Pour nettoyer l'appareil, essuyez délicatement l'extérieur avec un chiffon doux et sec. N'utilisez pas de nettoyants abrasifs ni de solvants et n'immergez pas l'appareil dans l'eau. Assurez-vous que les orifices de ventilation du capteur sont exempts de poussière et de débris.
5.2 Entretien de la batterie
To maximize battery lifespan, avoid fully discharging the device frequently. For prolonged storage, charge the battery to approximately 50% and store in a cool, dry place. If using the device continuously, it is recommended to keep it plugged in to a power source.
6. Dépannage
- Mesures de CO2 inexactes : If you suspect inaccurate readings, take the device outdoors for 10-15 minutes to allow it to recalibrate to ambient CO2 levels (typically around 400-450 ppm). Ensure the sensor vents are not obstructed.
- Durée de vie de la batterie courte : Ensure the device is fully charged before use. Adjust the backlight brightness to a lower setting to conserve power. For continuous monitoring, keep the device connected to a power source via the Type-C cable.
- L'appareil ne s'allume pas : Check if the battery is charged. Connect the device to a power source and attempt to power it on again. If the issue persists, contact customer support.
- L'alarme ne sonne pas : Verify that the alarm thresholds are set correctly and that the alarm function is enabled in the device settings.
7. Spécifications
| Fonctionnalité | Spécification |
|---|---|
| Marque | Prolongation LFF |
| Numéro de modèle | LAQ962 |
| Source d'énergie | Alimenté par batterie (5 volts CC) |
| Type de batterie | 1 batterie lithium-ion (incluse) |
| Poids de l'article | 7.04 onces |
| Dimensions du produit | 2.99 x 1.42 x 3.78 pouces |
| Type d'alarme | Audible |
| Type de capteur | Infrarouge non dispersif (NDIR) |
| Indice de température supérieur | 122 degrés Fahrenheit |
| Appareils compatibles | Câble de type C |
| Type de montage | Intégré |

8. Garantie et assistance
LFF is committed to providing quality products and customer satisfaction. If you encounter any issues or have questions regarding your LFF CO2 Detector, please do not hesitate to contact our customer service. We are dedicated to assisting you and ensuring your complete satisfaction.
For support, please refer to the contact information provided with your purchase or visit the official LFF website.