Prity AM W12

Prity AM W12 Wood-Burning Stove with Boiler for Central Heating

Manuel d'instructions

1. Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Prity AM W12 wood-burning stove with an integrated boiler for central heating. Please read this manual thoroughly before using the appliance and retain it for future reference. The Prity AM W12 is designed to provide both room heating and hot water for your central heating system.

2. Consignes de sécurité

Votre sécurité et celle des autres sont primordiales. Veuillez toujours respecter les consignes de sécurité suivantes :

  • Installation professionnelle : Installation must be performed by a qualified professional in accordance with all local and national building codes and regulations.
  • Matériaux combustibles : Maintain minimum clearances from combustible materials. As per EN 13240:2001/A2:2004/AC:2007, the minimum distances are:
    • Arrière : 400 mm
    • Sides (left and right): 400 mm
    • Front (radiation from pane): 800 mm
    • Plafond : 600 mm
  • Type de carburant : Only use dry wood with a moisture content of ≤20% or charcoal. Never use flammable liquids, plastics, or treated wood as fuel.
  • Surfaces chaudes : The stove's exterior surfaces become extremely hot during operation. Use appropriate protective gloves when handling and keep children and pets away.
  • Ventilation: Ensure adequate ventilation in the room where the stove is installed to prevent oxygen depletion.
  • Chimney/Flue: Regularly inspect and clean the chimney and flue pipe to prevent creosote buildup and ensure proper draft.
  • Monoxyde de carbone: Installez un détecteur de monoxyde de carbone à proximité du poêle.
  • Système d'eau : The integrated boiler must be connected to a closed central heating system by a qualified plumber. Ensure the system is properly filled and vented. The maximum working pressure is 1.25 bar.

This product complies with EN standard, CE certification, BlmSchV2, and ECO design regulations.

3. Configuration et installation

The Prity AM W12 is designed for corner placement and built-in installation. Proper setup is crucial for safety and performance.

3.1 Déballage et inspection

Déballez soigneusement le poêle et vérifiez qu'il n'a pas été endommagé pendant le transport. Signalez immédiatement tout dommage à votre fournisseur.

3.2 Placement

Position the stove in the desired corner, ensuring it meets the minimum clearance requirements from combustible materials as detailed in the Safety Instructions section.

Prity AM W12 wood-burning stove installed in a corner with a fire burning inside.

Image 3.2.1: The Prity AM W12 stove installed in a corner setting, demonstrating typical placement.

3.3 Connexion du tuyau de fumée

Connect the stove to a suitable chimney or flue system. The flue pipe diameter required is 150 mm. Ensure all connections are sealed properly to prevent smoke leakage and ensure optimal draft.

3.4 Central Heating System Connection

The integrated water boiler requires connection to your central heating system. This must be done by a certified plumber. The boiler has a volume of 7 liters and is designed to operate at a maximum working pressure of 1.25 bar. Ensure the system is properly filled, vented, and tested for leaks before initial firing.

Côté view of the Prity AM W12 wood-burning stove, showing the flue pipe connection point at the top.

Image 3.4.1 : Côté view of the Prity AM W12 stove, highlighting the flue outlet and overall construction.

4. Mode d'emploi

Follow these steps for safe and efficient operation of your Prity AM W12 stove.

4.1 Alimentation du poêle

Open the main combustion chamber door using the wooden handle. Place a small amount of kindling and firelighters on the cast iron grate. Once ignited, gradually add small pieces of dry wood or charcoal. Do not overfill the combustion chamber.

Prity AM W12 wood-burning stove with a vibrant fire burning inside the combustion chamber.

Image 4.1.1: The Prity AM W12 stove in operation, showing a fire burning within the heat-resistant ceramic glass window.

Prity AM W12 wood-burning stove with the combustion chamber door closed, showing the empty interior and cast iron grate.

Image 4.1.2: The Prity AM W12 stove with the combustion chamber empty, illustrating the interior design and cast iron grate.

4.2 Air Supply Control

The stove is equipped with a front damper for regulating the air supply to the combustion chamber. Open the damper fully during ignition to establish a strong fire. Once the fire is established, adjust the damper to control the burn rate and heat output. A fully open damper provides more air, leading to a hotter, faster burn. A partially closed damper reduces air, resulting in a slower, more efficient burn.

4.3 Flame Intensity Adjustment

Une fumée damper is provided to adjust the flame intensity. This allows for fine-tuning of the combustion process and heat distribution.

4.4 Ravitaillement

When adding more fuel, open the air damper fully for a few minutes before opening the combustion chamber door. This helps to prevent smoke from entering the room. Add fuel carefully and close the door securely.

5. Entretien

Regular maintenance ensures the longevity and efficient operation of your Prity AM W12 stove.

5.1 Enlèvement des cendres

Regularly remove ash from the ash pan located below the combustion chamber. Ensure the stove is completely cool before performing this task. Dispose of ash in a non-combustible container.

5.2 Cleaning the Combustion Chamber

Periodically clean the interior of the combustion chamber, including the heat-resistant ceramic glass. Use a soft brush or vacuum cleaner for ash and a specialized glass cleaner for stove glass. Do not use abrasive cleaners.

5.3 Flue Pipe and Chimney Cleaning

The flue pipe and chimney should be inspected and cleaned at least once a year, or more frequently depending on usage. This prevents creosote buildup, which can lead to chimney fires and reduced efficiency. This task should be performed by a qualified chimney sweep.

5.4 Boiler System Check

Regularly check the pressure in your central heating system and ensure it is within the recommended operating range. Inspect all connections for leaks. Consult a qualified plumber for any issues with the boiler system.

6. Dépannage

This section addresses common issues you might encounter with your Prity AM W12 stove. For complex problems, consult a qualified technician.

  • Poor Draft / Smoke in Room:
    • Check if the flue pipe or chimney is blocked and requires cleaning.
    • Assurez-vous que l'air dampers are open sufficiently.
    • Verify that the chimney height and diameter are adequate for the stove.
    • Check for negative pressure in the room (e.g., due to extractor fans).
  • Faible production de chaleur :
    • Utilisez du bois sec et bien séché. Le bois humide brûle mal.
    • Check if the air dampers are open enough.
    • Verify that the combustion chamber and ash pan are clean.
  • Excessive Fuel Consumption:
    • Ajuster l'air dampers to reduce the burn rate.
    • Ensure the stove door seals are intact and not allowing excess air.
  • Water System Not Heating:
    • Check the central heating system pressure.
    • Ensure the boiler is receiving sufficient heat from the combustion.
    • Bleed the radiators and the boiler system to remove any airlocks.
    • Consult a qualified plumber if the issue persists.

7. Spécifications

Detailed technical specifications for the Prity AM W12 wood-burning stove with boiler:

Table showing product information and technical specifications for Prity AM W12 stove.

Image 7.1.1: Product Information table for Prity AM W12, detailing various technical specifications.

FonctionnalitéSpécification
Numéro de modèleAM W12
Dimensions totales (L x P x H)720 x 550 x 820 mm
Combustion Chamber Dimensions (W x D x H)635 x 450 x 315 mm
Poids net113 kg
Nominal Room Heating Output6.2 kW
Nominal Water Heating Output7.3 kW
Maximum Water Heating Output12 kW
Diamètre du conduit de fumée150 mm
Efficacité76.5%
Volume of Water Heater7 L
Estimated Heating Area105 m²
Estimated Heating Capacity277 m³
Matériau du corps2 mm thick sheet steel
Matériau supérieur3-4 mm thick sheet steel
Type de carburantWood, Charcoal (Dry wood with moisture content ≤20%)
Pression de service maximale1.25 barres
Flue Gas Temperature at Nominal Heat Output180 °C
Tirant de cheminée minimum11.4 Pa
Consommation de carburant4.3 kg/h
Connexion des raccords3/4"
Classe d'efficacité énergétiqueA
Indice d'efficacité énergétique (IEE)102
Efficacité énergétique saisonnière du chauffage des locaux (ηs)68%
CouleurNoir Graphite
Composants inclusCast iron grate, Wooden door handles
Energy efficiency label for Prity AMW12 stove, showing an A rating and heat output values.

Image 7.1.2: Energy Label for Prity AMW12, indicating an A-class energy efficiency rating.

German Declaration of Performance for Prity AMW12, detailing compliance with standards and technical data.

Image 7.1.3: German Declaration of Performance for Prity AMW12, showing compliance and performance data.

English Declaration of Performance for Prity AMW12, detailing compliance with standards and technical data.

Image 7.1.4: English Declaration of Performance for Prity AMW12, providing essential performance characteristics.

EAN/Barcode: 3800215095054

8. Garantie et assistance

For warranty information, please refer to the documentation provided at the time of purchase or contact your retailer. In case of technical issues or questions not covered in this manual, please contact Prity customer support or your authorized service provider.

Documents connexes - AM W12

Préview Prity Fireplaces and Fireboxes: Installation and Operation Manual
Comprehensive guide for Prity fireplaces and fireboxes, covering technical specifications, installation procedures, operation instructions, maintenance, and warranty information. Ensure safe and efficient use of your Prity heating appliance.
Préview Chaudières Prity : Manuel de description technique, d'installation et d'utilisation
Guide complet des chaudières résidentielles Prity, couvrant les spécifications techniques, les procédures d'installation, les instructions d'utilisation, l'entretien et le dépannage des modèles à combustible solide et à granulés.
Préview Manuel d'utilisation du chargeur portable sans fil W12
Manuel d'utilisation du chargeur portable sans fil W12 de Guangdong Gadmei Intelligent Technology Co., LTD. Découvrez les caractéristiques du produit, ses spécifications, les méthodes de charge, les précautions de sécurité et le dépannage.
Préview Casque Bluetooth SANSUI W12 - Spécifications et conformité FCC
Informations officielles concernant le casque Bluetooth SANSUI W12, y compris les spécifications techniques et les déclarations de conformité FCC.