1. Plus deview
The waveshare FT232RNL USB to RS232/485/422/TTL Interface Converter is an industrial-grade isolated converter designed for reliable and stable communication across various serial interfaces. It leverages an original FT232RNL chip for superior performance and compatibility. This device is engineered with multiple protection features to ensure safe and durable operation in diverse environments.

Figure 1: waveshare FT232RNL USB to RS232/485/422/TTL Interface Converter
2. Caractéristiques
- Original FT232RNL Chip: Ensures fast, stable, and reliable communication with enhanced compatibility.
- Multi-Interface Conversion: Supports USB to RS232, USB to RS485, USB to RS422, and USB to TTL.
- Unibody Power Supply Isolation: Provides stable isolated voltage without requiring external power for the isolated terminal.
- Unibody Digital Isolation: Allows signal isolation, offering high reliability, strong anti-interference, and low power consumption.
- TVS (vol transitoiretage Suppressor): Effectively suppresses surge voltage et transitoire transitoire voltage, providing lightningproof and ESD protection.
- Self-Recovery Fuse & Protection Diodes: Ensures stable current/voltage outputs, offering over-current/over-voltage proof and improved shock resistance.
- Automatic Transceiver Circuit: Fully automatic, no-delay transceiver circuit for fast and stable communication without interference.
- TTL Serial 3.3V/5V Voltage Translator: Configurable TTL level via switch.
- Indicateurs LED : Three LEDs indicate power (PWR) and transceiver status (TXD, RXD).
- High-Quality Connectors: Durable USB-B and RS232 connectors for smooth plug/pull.
- Industrial-Grade Metal Case: Supports wall-mount and rail-mount installations, providing a solid and aesthetically pleasing design.

Figure 2: Internal Design and Protection Features
3. Contenu de l'emballage
L'emballage du produit comprend généralement les éléments suivants :
- waveshare FT232RNL USB to RS232/485/422/TTL Interface Converter
- Câble USB-A vers USB-B
- Tournevis
- Supports de montage (pré-attachés ou séparés)

Figure 3 : Contenu de l'emballage
4. Installation
To set up your waveshare FT232RNL converter, follow these general steps:
- Se connecter à l'hôte : Use the provided USB-A to USB-B cable to connect the converter's USB-B port to a USB port on your computer (PC, Mac, Linux, Android device).
- Installation du pilote : For most modern operating systems (Windows, Linux, Mac, Android), the necessary drivers for the FT232RNL chip should install automatically upon connection. If not, drivers can be obtained from the FTDI website or waveshare's official support page.
- Select TTL Level (if applicable): If using the TTL interface, adjust the 3.3V/5V voltage translator switch on the converter to match the voltage level of your target device.
- Connecter un périphérique série : Connect your RS232, RS485, RS422, or TTL serial device to the corresponding screw terminals or DB9 connector on the converter. Ensure correct pin assignments (refer to Section 6: Interface Introduction).
- Vérifiez la connexion : The PWR LED on the converter should illuminate when connected to a powered USB port. The TXD and RXD LEDs will flash during data transmission.
Video 1: Demonstrates the connection and various interface conversions of the waveshare USB to RS232/485/422/TTL converter.
5. Fonctionnement
Once the converter is set up and connected, it operates as a transparent bridge between your USB host and the connected serial device. The onboard automatic transceiver circuit manages data flow without manual intervention.
Indicateurs LED :
- PWR (Rouge) : Indicates power. Lights up when the USB connection is established and voltage est détecté.
- TXD (Green): Transmit Data Indicator. Lights up when the USB port sends data.
- RXD (Green): Receive Data Indicator. Lights up when the device ports send data back.
To communicate with your serial device, use appropriate serial communication software on your computer. Configure the software with the correct COM port (assigned by your operating system), baud rate, data bits, parity, and stop bits to match your serial device's settings.
6. Présentation de l'interface
The converter provides multiple interfaces for versatile connectivity:

Figure 4 : Plusview of Converter Interfaces
RS232 Pinout (DB9 Male):
| ÉPINGLE | Description |
|---|---|
| 2 | Receiving data (RXD) |
| 3 | Sending data (TXD) |
| 5 | Terre GND |
| 1, 4, 6, 7, 8, 9 | N/C (Not Connected) |
RS485/RS422 Pinout (Screw Terminal):
| Screw Terminal (PIN) | Description |
|---|---|
| PE | 485/422 signal ground |
| TA | RS422 send differential signal positive / RS485 differential signal positive A+ |
| TB | RS422 send differential signal negative / RS485 differential signal negative B- |
| RA | RS422 receive differential signal positive |
| RB | RS422 receive differential signal negative |
TTL (UART) Pinout (Screw Terminal):
| Screw Terminal (PIN) | Description |
|---|---|
| TXD | TTL transmit data pin, connect to MCU.RXD |
| RXD | TTL receive data pin, connect to MCU.TXD |
| Terre | Se connecter à GND |
| CCV | 5V / 3.3V power supply output, configurable via 5V/3.3V level switch |

Figure 5: Detailed Pinouts
7. Spécifications
| Catégorie | Spécification |
|---|---|
| Type de produit | Industrial grade digital isolated converter |
| Vol d'exploitationtage | 5V (USB) / 3.3V / 5V (TTL) |
| Connecteur USB | USB-B |
| Protection USB | Fusible à récupération automatique de 200 mA, sortie isolée |
| Connecteur RS232 | DB9 mâle |
| Protection RS232 | Diode TVS, protection contre les surtensions et les décharges électrostatiques |
| RS232 Transmission Mode | Point à point |
| Débit en bauds RS232 | 300bps ~ 921600bps |
| Connecteur RS485/422 | Borne à vis |
| RS485/422 Direction Control | Hardware automatic control |
| RS485/422 Protection | 600W lightningproof and surge-suppress, 15KV ESD protection (reserved two 120R balancing resistors, enabled/disabled via jumper) |
| RS485/422 Transmission Mode | Point-to-multipoints (485 mode: up to 32 nodes, repeaters recommended for 16+ nodes; 422 mode: up to 256 nodes, repeaters recommended for 16+ nodes) |
| RS485/422 Baud Rate | 300 bits/s ~ 2 Mbit/s |
| TTL (UART) Connector | Borne à vis |
| TTL (UART) Pins | TXD, RXD, GND, 5V/3.3V |
| TTL (UART) Protection | Clamp diode de protection, survoltage/négatif-voltage preuve, résistance aux chocs |
| TTL (UART) Transmission Mode | Point à point |
| TTL (UART) Baud Rate | 300 bits/s ~ 2 Mbit/s |
| Température de fonctionnement | -40°C ~ 85°C |
| Humidité de fonctionnement | 5% d'humidité relative à 95% d'humidité relative |
| Systèmes d'exploitation pris en charge | Mac, Linux, Android, Windows 11/10/8.1/8/7 |
| Dimensions du colis | 6.14 x 4.33 x 1.26 pouces |
| Poids de l'article | 1.76 onces |
| Fabricant | Waveshare |
| Date de première disponibilité | 6 février 2023 |

Figure 6 : Dimensions du contour (Unité : mm)
8. Entretien
To ensure the longevity and optimal performance of your waveshare FT232RNL converter, follow these maintenance guidelines:
- Nettoyage: Use a soft, dry cloth to clean the exterior of the device. Avoid using liquid cleaners or solvents, which may damage the casing ou composants internes.
- Environnement: Operate and store the converter in a clean, dry environment, away from excessive dust, moisture, and extreme temperatures. Refer to the operating temperature and humidity specifications.
- Manutention: Handle the device with care. Avoid dropping it or subjecting it to strong impacts, which could damage the internal circuitry.
- Relations: Ensure all cable connections are secure and free from strain. Periodically check screw terminals for tightness.
9. Dépannage
If you encounter issues with your waveshare FT232RNL converter, consider the following troubleshooting steps:
- Pas d'alimentation (voyant PWR éteint) :
- Ensure the USB cable is securely connected to both the converter and the host computer.
- Essayez un autre port USB sur votre ordinateur.
- Verify that your computer's USB port is providing power.
- No Data Transmission (TXD/RXD LEDs not flashing):
- Check all serial connections (RS232, RS485, RS422, TTL) for correct wiring and secure connections.
- Verify that the serial communication software on your computer is correctly configured (COM port, baud rate, data bits, parity, stop bits).
- Ensure the TTL level switch is set correctly for your TTL device (3.3V or 5V).
- Confirm that the connected serial device is powered on and functioning correctly.
- Problèmes de pilote :
- If the device is not recognized by your operating system, try reinstalling the FTDI drivers. These can typically be found on the FTDI website.
- Check your device manager (Windows) or equivalent system information (Linux/Mac) to see if the device is listed without errors.
- Ingérence:
- While the device has strong anti-interference capabilities, ensure it is not placed near strong electromagnetic interference sources.
10. Garantie et assistance
For warranty information, technical support, or further assistance with your waveshare FT232RNL USB to RS232/485/422/TTL Interface Converter, please contact waveshare directly through their official weble site ou le détaillant auprès duquel vous avez acheté le produit.
Un guide d'utilisation officiel au format PDF est également disponible au téléchargement : Guide de l'utilisateur (PDF)