1. Introduction
Merci pour votre achatasing the AGV LIGHTING CL025 Crystal Semi-Flush Mount Ceiling Light Fixture. This manual provides essential information for the safe installation, operation, and maintenance of your new lighting fixture. Please read these instructions thoroughly before beginning installation and retain them for future reference.

Image 1.1: The AGV LIGHTING CL025 Crystal Semi-Flush Mount Ceiling Light Fixture. This image shows the fixture unlit, highlighting its matte black and shine gold finish with clear K9 crystals.
2. Consignes de sécurité
- AVERTISSEMENT: Risque de choc électrique. Coupez l'alimentation au niveau du disjoncteur ou du tableau électrique avant toute installation ou intervention.
- Tous les raccordements électriques doivent être conformes aux codes et règlements locaux, ainsi qu'au Code national de l'électricité (NEC). Consultez un électricien qualifié si vous n'êtes pas familiarisé avec les raccordements électriques appropriés.
- This fixture is intended for indoor use only. Do not expose to water or moisture.
- Use only E12 base bulbs, maximum 60W per bulb. Do not exceed the recommended wattage.
- Handle crystal components with care to prevent breakage. It is recommended to wear gloves during crystal installation to avoid fingerprints.
- Vérifiez que la surface de montage peut supporter le poids du dispositif.
3. Contenu du colis
Verify that all components are present before beginning installation. If any parts are missing or damaged, contact AGV LIGHTING customer support.
- Fixture Body (with integrated wiring)
- Support de montage
- Crystal Shade Components
- Decorative Crystal Drop
- Matériel de montage (vis, connecteurs de fils)
- Manuel d'instructions
- White Gloves (for crystal handling)
4. Spécifications
| Marque | AGV LIGHTING |
| Numéro de modèle | CL025 |
| Dimensions du produit | 12 po L x 12 po l x 13 po H (31 cm x 31 cm x 33 cm) |
| Matériel | Alloy Steel, K9 Crystal |
| Type de finition | Matte Black & Shine Gold |
| Type d'installation | Montage semi-encastré |
| Nombre de lumières | 4 |
| Culot de l'ampoule | E12 |
| Max Vattage par ampoule | 60 watts |
| Voltage | 120 volts |
| Dossier spécial | Intensité variable (avec ampoules et variateur compatibles) |
| Poids de l'article | 6.93 livres |

Image 4.1: Detailed dimensions of the CL025 fixture, showing a diameter of 12 inches (31cm) and a height of 13 inches (33cm).
5. Configuration et installation
Important: Before starting, ensure the power is turned off at the circuit breaker. If you are unsure about electrical wiring, consult a qualified electrician.
- Préparez l'installation : Turn off the main power supply to the junction box at the circuit breaker. Clear the work area and gather all necessary tools (screwdriver, wire strippers, electrical tape, etc.).
- Fixer le support de montage : Secure the mounting bracket to the ceiling junction box using the screws provided. Ensure the bracket is firmly attached and level.
- Câbler le luminaire : Carefully connect the fixture's wires to the corresponding wires from the junction box.
- Connectez le noir (live) wire from the fixture to the noir (live) wire from the junction box.
- Connectez le blanc (neutral) wire from the fixture to the blanc (fil neutre) provenant de la boîte de jonction.
- Connectez le sol fil (cuivre nu ou vert) du luminaire au sol fil de la boîte de jonction.
- Monter le corps du luminaire : Carefully lift the fixture body and align the mounting holes with the screws on the mounting bracket. Secure the fixture to the bracket using the provided nuts or screws.
- Installez les ampoules : Screw four E12 base bulbs (not included, max 60W each) into the sockets.
- Fixer les composants Crystal : Wearing the provided white gloves, carefully attach the crystal shade components to the fixture body according to the diagram (if provided) or by hooking them onto the designated loops. Finally, attach the decorative crystal drop to the bottom of the fixture.

Image 5.1 : Un gros plan view illustrating the clear K9 crystal components and the E12 bulb base, showing where bulbs are inserted.

Image 5.2 : Un aperçu détaillé view of the fixture's construction, showing the matte black frame, gold accents, and the arrangement for crystal attachment.
6. Mode d'emploi
Once the fixture is securely installed and bulbs are in place, restore power at the circuit breaker. The light fixture can then be operated using your standard wall switch.
- Fonction Marche/Arrêt : Utilisez l'interrupteur mural relié au luminaire pour allumer ou éteindre les lumières.
- Fonction de gradation: This fixture is dimmable. To utilize the dimming feature, you must use dimmable E12 bulbs and a compatible dimmer switch (both sold separately). Follow the dimmer switch manufacturer's instructions for installation and operation.

Image 6.1: The AGV LIGHTING CL025 fixture illuminated, showcasing the light dispersion and crystal sparkle.
7. Entretien
Un entretien régulier contribuera à préserver l'apparence et le bon fonctionnement de votre luminaire.
- Nettoyage: Ensure the power is off before cleaning. For the metal frame, wipe with a soft, dry cloth. For the crystal components, use a soft, damp cloth with a mild glass cleaner, or a specialized crystal cleaner. Avoid abrasive cleaners or harsh chemicals that may damage the finish or crystals.
- Remplacement de l'ampoule : Always turn off the power before replacing bulbs. Allow old bulbs to cool before removing. Replace with E12 base bulbs, ensuring the wattage does not exceed 60W per bulb.
- Inspection: Vérifiez régulièrement toutes les connexions et les éléments de fixation pour vous assurer qu'ils restent bien en place.
8. Dépannage
If you encounter issues with your fixture, refer to the following common problems and solutions:
| Problème | Cause possible | Solution |
|---|---|---|
| La lumière ne s'allume pas. | Pas d'alimentation à l'appareil. Connexions de fils desserrées. Ampoule défectueuse. | Vérifiez le disjoncteur et l'interrupteur mural. Assurez-vous que toutes les connexions électriques sont bien fixées (coupez l'alimentation au préalable). Replace bulb with a new one. |
| La lumière clignote. | Ampoule lâche. Type d'ampoule incorrect pour le variateur. Faulty dimmer switch. | Serrer l'ampoule. Veillez à utiliser des ampoules à intensité variable avec un variateur. Consult an electrician to check or replace the dimmer switch. |
| La variation d'intensité lumineuse ne fonctionne pas. | Non-dimmable bulbs. Interrupteur variateur incompatible. | Use only dimmable E12 bulbs. Ensure the dimmer switch is compatible with LED or incandescent bulbs, depending on your bulb type. |
If these steps do not resolve the issue, please contact AGV LIGHTING customer support.
9. Garantie et assistance
For warranty information or technical assistance, please contact AGV LIGHTING customer support through the retailer where the product was purchased or visit the official AGV LIGHTING website. Please have your model number (CL025) and purchase date available when contacting support.