1. Introduction

This manual provides essential information for the proper installation, operation, and maintenance of your FireAngel FA6120 Optical Smoke Alarm. The FA6120 is designed for early detection of slow-burning fires, featuring an advanced optical sensor and a sealed 10-year battery for continuous protection. It serves as a direct replacement for older FireAngel ST-622/ST-620 models.

2. Produit terminéview

The FireAngel FA6120 is a compact, optical smoke alarm engineered for reliable home fire safety. Its key features include:

  • Capteur optique: Detects smoke from slow-burning fires, reducing false alarms from cooking fumes.
  • Batterie scellée de 10 ans : Provides continuous power for the entire lifespan of the alarm, eliminating the need for battery replacement.
  • Bouton Test/Silence : Allows for easy testing of the alarm's functionality and temporary silencing of nuisance alarms or low battery warnings.
  • Sleep Easy™ Function: Temporarily silences low battery warnings for 8 hours, ideal for nighttime alerts, while maintaining smoke detection capability.
FireAngel FA6120 Optical Smoke Alarm front view

Figure 1 : Devant view of the FireAngel FA6120 Optical Smoke Alarm, showing the central test/silence button and FireAngel branding.

3. Consignes de sécurité

Votre sécurité est primordiale. Veuillez respecter les consignes suivantes :

  • The FA6120 smoke detector is CE marked and certified to EN 14604:2005+AC:2008 standards, and carries the Q-label, ensuring high safety and performance.
  • The integrated battery is sealed and non-replaceable. Do not attempt to open the unit or replace the battery.
  • Avoid placing the alarm near bathrooms or kitchens, as steam and cooking fumes can trigger nuisance alarms.
  • Regularly test your smoke alarm as described in the Operating Instructions section.

4. Configuration et installation

The FireAngel FA6120 is designed for easy installation. Follow these steps to properly mount your smoke alarm:

  1. Choisissez l'emplacement: Select a suitable location on the ceiling, ensuring it is at least 300 mm (12 inches) away from luminaires (light fixtures) and walls. Smoke alarms are suitable for habitable recreational vehicles. Do not install in kitchens or bathrooms due to potential nuisance alarms from steam or cooking fumes.
  2. Plaque de base de montage : Use the provided screws (not supplied with the alarm, typically standard mounting screws) to fix the removable base plate securely to the ceiling. The base plate is identical to that of the ST622 model, allowing for easy replacement.
  3. Attacher l'alarme : Once the base plate is mounted, push the smoke alarm onto the base plate and turn it clockwise until it clicks firmly into place.
Installation steps for FireAngel FA6120 smoke alarm

Figure 2 : Visual guide for installing the FireAngel FA6120, showing the removable base plate and the twist-on attachment method.

Placement guidelines for FireAngel smoke alarms

Figure 3 : Illustration of recommended placement, indicating a minimum distance of 300mm from walls and light fixtures, suitability for RVs, and unsuitability for kitchens/bathrooms.

5. Mode d'emploi

Understanding how to operate your smoke alarm ensures its effectiveness.

5.1. Test de l'alarme

To ensure your alarm is functioning correctly, press and hold the large central Test/Silence button. A loud alarm sound will confirm its proper operation. Test your alarm weekly.

5.2. Faire taire les alarmes intempestives

In the event of a false alarm (e.g., from cooking fumes or steam), press the Test/Silence button to temporarily silence the alarm for 10 minutes. Ensure the cause of the false alarm is identified and resolved.

5.3. Sleep Easy™ Function

If a low battery alert sounds during the night, you can activate the Sleep Easy™ function. Press the Test/Silence button to silence the low battery chirp for 8 hours. The red LED will continue to flash, indicating the low battery status. The alarm will still detect smoke during this period. Remember to replace the alarm within 30 days of the first low battery alert, as the battery is sealed and non-replaceable.

6. Entretien

Proper maintenance helps ensure the longevity and reliability of your smoke alarm.

  • Tests hebdomadaires : Test your smoke alarm weekly by pressing the Test/Silence button.
  • Nettoyage: Gently vacuum the alarm's casing once a month using a soft brush attachment to remove dust and cobwebs. Do not use cleaning solvents or sprays.
  • Batterie: The alarm features a sealed 10-year lithium battery that does not require replacement. When the alarm reaches the end of its 10-year lifespan or consistently indicates a low battery, the entire unit must be replaced.

7. Dépannage

Consultez le tableau ci-dessous pour connaître les problèmes courants et leurs solutions :

ProblèmeCause possibleSolution
L'alarme se déclenche par intermittence ou sans raison apparente.Nuisance alarm from steam, cooking fumes, or dust.Press the Test/Silence button to silence for 10 minutes. Clean the alarm. Relocate if consistently triggered by environmental factors.
L'alarme émet un signal sonore périodique (par exemple, toutes les 30 à 60 secondes).Avertissement de batterie faible.If at night, use Sleep Easy™ function. Replace the entire alarm unit within 30 days.
Alarm does not sound when Test button is pressed.Alarm malfunction or end of life.Ensure the alarm is correctly mounted. If still unresponsive, replace the unit immediately.

8. Spécifications

FonctionnalitéDétail
Numéro de modèleFA6120-INT
MarqueFireAngel
Type de capteurOptique
Source d'énergieSealed Lithium Battery (1 CR123A equivalent)
Autonomie de la batterie10 Years (non-replaceable)
Niveau sonore d'alarme85 dB(A) à 3 mètres
Dimensions (H x P)3.15 cm x 11.81 cm
Poids138 gramme
MatérielPlastique
CertificationsCE, EN 14604:2005+AC:2008, Q-label
Composants inclus1 x Baseplate, 1 x Instruction Manual, 1 x Optical Smoke Alarm with Sealed Lithium Battery

9. Garantie et assistance

The FireAngel FA6120 Optical Smoke Alarm comes with a 1-year availability for spare parts, as per EU regulations. For specific warranty details, technical support, or further assistance, please refer to the contact information provided in the packaging or visit the official FireAngel website. Always ensure you have your model number (FA6120-INT) ready when contacting support.

Documents connexes - FA6120-INT

Préview Manuel d'utilisation des détecteurs de fumée et de chaleur FireAngel : FA6611, FA6615, FA6620, FA6720
Manuel d'utilisation des détecteurs de fumée optiques FireAngel (FA6611, FA6615, FA6620) et des détecteurs de chaleur (FA6720). Ce manuel fournit des informations détaillées sur le positionnement, l'installation, l'entretien, le dépannage, les fonctions de silence et de sommeil paisible, la garantie et les instructions de mise au rebut pour assurer la sécurité incendie à domicile.
Préview FireAngel ST-620 Smoke Alarm User Manual: 10 Year Life
This user manual provides comprehensive instructions for the FireAngel ST-620 smoke alarm, detailing its 10-year lifespan, Thermoptek™ sensor technology, installation, operation, testing, maintenance, and troubleshooting. Ensure optimal fire safety with this essential guide.
Préview Manuel d'utilisation des détecteurs de fumée FireAngel FA6111, FA6115, FA6120 et du détecteur de chaleur FA6215
Manuel d'utilisation complet pour les détecteurs de fumée optiques FireAngel FA6111, FA6115, FA6120 et le détecteur de chaleur FA6215, couvrant l'installation, la maintenance, le dépannage, les fonctionnalités telles que Silence et Sleep Easy, la garantie et la mise au rebut.
Préview Manuel d'utilisation du détecteur de fumée FireAngel ST-625-INT
Manuel d'utilisation complet du détecteur de fumée FireAngel ST-625-INT : installation, fonctionnalités, entretien et garantie. Ce guide fournit les informations essentielles de sécurité et les instructions d'utilisation.
Préview Détecteur de fumée optique FireAngel ST-622-BNLT - Pile d'une durée de vie de 10 ans
Spécifications détaillées et description du détecteur de fumée optique FireAngel ST-622-BNLT. Caractéristiques : autonomie de 10 ans, technologie Thermoptek, mode Silence intelligent et chambre anti-insectes. Découvrez ses caractéristiques techniques et ses avantages.taget.
Préview Manuel d'utilisation des détecteurs de fumée et de chaleur FireAngel : FA6611, FA6615, FA6620, FA6720
Manuel d'utilisation complet pour les détecteurs de fumée optiques FireAngel FA6611, FA6615 et FA6620 et le détecteur de chaleur FA6720. Ce manuel couvre l'installation, la maintenance, le dépannage, la garantie et la mise au rebut.