Enttec 73539

Enttec DIN Pixie 73539 User Manual

2-Universe DMX LED Pixel Controller

1. Introduction

The Enttec DIN Pixie 73539 is a compact, DIN-rail mountable DMX to LED pixel protocol converter. It is designed to provide flexible control for architectural, commercial, and entertainment lighting installations by converting DMX512 signals into various LED pixel protocols.

This manual provides essential information for the safe and efficient operation of your DIN Pixie. Please read it thoroughly before installation and use.

2. Consignes de sécurité

WARNING: This unit is intended for indoor use only. Do not expose to rain or moisture. Doing so will void the warranty.

  • Never plug this unit into a dimmer.
  • Always be sure to mount this unit in an area that will allow sufficient ventilation.
  • Label any RJ45/6 DMX connector and DO NOT connect to non-DMX port (e.g., Ethernet Switch). Connecting unlike systems could result in serious damage to Storm8 and equipment.
  • All ports feature ESD surge protection and resettable fuses to block external faults and electrical noise propagation.

3. Contenu de la boîte

Vérifiez que tous les articles sont présents dans la boîte :

  • Enttec DIN Pixie unit
  • Support de montage DIN
  • USB Type-A to USB 2.0 Type B Cable

4. Survie physiqueview et connexions

Devant view of Enttec DIN Pixie with status LED and branding

Figure 4.1 : Face avant view of the Enttec DIN Pixie controller, showing the status LED and branding.

Haut view of Enttec DIN Pixie showing DMX input ports

Figure 4.2 : Haut view of the Enttec DIN Pixie, highlighting the two DMX input ports (DMX 1 and DMX 2) and the enttec.com URL.

Bas view of Enttec DIN Pixie showing USB and SPI outputs

Figure 4.3 : Bas view of the Enttec DIN Pixie, showing the USB 2.0 Type-B input and two 3-pin Phoenix SPI output terminals (labeled 1 and 2) with VCC limit 5-48VDC.

4.1. DMX Input (RJ45)

The DIN Pixie features two RJ45 ports for DMX input. These ports are compliant with ANSI E1.27-2.

RJ45 Pin for DMX Input
ÉpingleFonction
Broche 1Données +
Broche 2Data -
Broche 7/8Sol

4.2. SPI Output (3 Pin Phoenix)

The unit provides two 3-pin Phoenix connectors for SPI output. These outputs deliver power and data to your LED pixels. Ensure the VCC limit of 5-48VDC is respected.

  • 0V: Ground connection for the pixel strip.
  • DONNÉES: Data signal for the pixel strip.
  • CCV: Voltage supply for the pixel strip (5-48VDC).

4.3. USB 2.0 Type-B Input

A robust USB Type-B connector is provided for configuration and firmware updates. It is also backward compatible with the Enttec Pixie Driver API for USB-SPI control.

5. Configuration et installation

5.1. Montage

The DIN Pixie is designed for DIN-rail mounting. Use the included DIN Mounting Bracket to secure the unit to a standard DIN rail.

Bas view of Enttec DIN Pixie with DIN rail clip attached

Figure 5.1 : Bas view of the Enttec DIN Pixie showing the attached DIN rail mounting clip.

5.2. Alimentation de l'unité

The DIN Pixie operates on a wide voltage range of 5-48VDC. It can be powered from the same source as your LED pixels via the VCC and 0V terminals on the SPI output connectors. Alternatively, power can be supplied via the USB connection.

5.3. Connecting LED Pixels

Connect your LED pixel strips or dots to the SPI output terminals. Ensure correct polarity (0V, DATA, VCC) and that the voltage supplied matches the requirements of your pixel strips and is within the 5-48VDC limit of the DIN Pixie.

The DIN Pixie supports RGB and RGBW pixel strips and dots.

5.4. DMX Input Connection

Connect your DMX source to the RJ45 DMX input ports. The unit can receive DMX512-A data.

5.5. Configuration

The DIN Pixie is configurable and updatable via USB using Enttec's free PRO-MANAGER software. This software allows you to:

  • Configure DMX starting address.
  • Set pixel grouping functions to optimize channel usage.
  • Select between control modes.
  • Test output sequences (no external data source required).
  • Mise à jour du firmware.

For the latest version of PRO-MANAGER software and drivers, visit the official Enttec website: enttec.com

6. Modes de fonctionnement

The DIN Pixie supports various operating modes, indicated by the status LED:

  • SUR: Overheating/Error
  • 0.5Hz: Inactif
  • 2Hz: Standalone playback
  • 8Hz: Réception DMX
  • 25Hz: Receiving from USB

6.1. Mode de contrôle DMX

When receiving DMX data, the DIN Pixie converts up to 2 DMX universes (1024 channels) into SPI pixel protocols. The DMX starting address and pixel grouping can be configured via PRO-MANAGER.

The unit can be configured to play a show on DMX loss or blackout output, providing a fail-safe mechanism.

6.2. Standalone Playback Mode

The DIN Pixie has inbuilt flash memory for standalone show playback (4000 frames, approximately 100 seconds). Shows can be recorded and uploaded using PRO-MANAGER. Standalone playback can include sequence advance control options such as play count, loop delay, and play on power up.

6.3. USB Control Mode

The DIN Pixie can be controlled directly via the USB Type-B connector using the Enttec Pixie Driver API. This allows for direct control from a computer or compatible device.

7. Entretien

The Enttec DIN Pixie is designed for reliable operation and requires minimal maintenance.

  • Nettoyage: Utilisez un chiffon doux et sec pour nettoyer l'extérieur de l'appareil. N'utilisez pas de nettoyants liquides ni de solvants.
  • Mises à jour du micrologiciel : Periodically check the Enttec website for firmware updates. Keeping the firmware current ensures optimal performance and access to new features. Firmware updates are performed using the PRO-MANAGER software.
  • Ventilation: Ensure the unit is mounted in an area with adequate ventilation to prevent overheating.

8. Dépannage

If you encounter issues with your DIN Pixie, refer to the following common troubleshooting steps:

  • Pas d'alimentation/voyants LED éteints :
    • Check power connections to the VCC/0V terminals or USB port.
    • Assurer l'alimentation voltage se situe dans la plage 5-48VDC.
    • Vérifiez que la source d’alimentation est active.
  • No Pixel Output:
    • Confirm correct wiring of 0V, DATA, and VCC to the pixel strips.
    • Check if the DMX source is active and sending data (status LED should be 8Hz).
    • Verify pixel protocol and DMX starting address settings in PRO-MANAGER.
    • Ensure the pixel strips themselves are functional.
  • DMX Input Not Detected (LED 8Hz not flashing):
    • Check DMX cable connections.
    • Ensure the DMX source is transmitting.
    • Confirm the DMX source is using USITT DMX512-A protocol.
  • PRO-MANAGER Connection Issues:
    • Assurez-vous que le câble USB est correctement connecté.
    • Install the correct FTDI drivers for your operating system. Refer to the Enttec website for driver information.
    • Restart PRO-MANAGER and reconnect the USB cable.
  • Overheating/Error (LED ON):
    • Check for adequate ventilation around the unit.
    • Ensure the ambient temperature is within the operating range (0°C to 50°C).
    • Reduce the load on the SPI outputs if possible.

For further assistance, please contact Enttec support or visit their website for detailed guides and FAQs.

9. Spécifications

FonctionnalitéSpécification
Connecteurs1x USB 2.0 Type-B Input, 2x DMX Input (RJ45), 2x SPI Output (3 Pin Phoenix)
Protection ESDResettable fuse per port
Indice de protection IPIP20
Indicateur LEDYes (Power and output status)
Protocole d'entréeUSITT DMX512-A
Data Output TypeSPI (Supported protocols listed on Enttec webet données clients liées)
Maximum Output Channels2 Universes (1024ch), duplicated on both ports
Max. Output Refresh Rate40 images par seconde
Latence5 millisecondes
Vol d'entréetage5 - 48V DC (via USB/Ether output port VCC terminal)
Consommation électrique maximale1.5 W
Max. Rated Current per screw terminal (VCC / 0V)10A
Logiciel de configurationPRO-MANAGER
Mises à jour du firmwarePRO-MANAGER
Show Recording/UploadPRO-MANAGER
Température de fonctionnement environnementale0°C à 50°C (32°F à 122°F)
Humidité de fonctionnement environnementale5-95% (sans condensation)
Matériau du corpsPlastique ABS
Option de montageVACARME
Poids unitaire95 g / 3.3 oz
Dimensions (H x l x L)1.22 x 3.07 x 3.66 pouces (30.9 x 77.9 x 92.98 mm)
Poids à l'expédition0.22kg / 0.49lbs

Note: For the most current and detailed specifications, please refer to the official Enttec datasheet on their website.

10. Garantie et assistance

10.1. Garantie

The Enttec DIN Pixie comes with a 2-year return to base manufacturer warranty, supported by 3rd party software. For detailed warranty terms and conditions, please visit the official Enttec website.

10.2. Assistance technique

For technical assistance, troubleshooting, or further information, please visit the Enttec webconsultez le site ou contactez leur équipe d'assistance :

  • Website: www.enttec.com
  • Se référer à la website contenant les coordonnées et les ressources d'assistance.

Documents connexes - 73539

Préview Manuel d'utilisation ENTTEC DIN PIXIE : Contrôleur de bande/point de pixels SPI
Manuel d'utilisation de l'ENTTEC DIN PIXIE, un contrôleur SPI Pixel Strip/Dot gérant deux univers de pixels LED sur deux sorties. Ce manuel couvre la sécurité, les spécifications, le câblage, les fonctionnalités (USB, DMX, modes autonomes), le logiciel PRO-Manager, la configuration de l'appareil, les mises à jour du firmware, les tests, le montage, la maintenance, le contenu du colis et les informations de commande.
Préview ENTTEC Custom Protocol Creation Guide for Pixel Fixtures
Learn how to create custom DMX protocols for LED pixel fixtures with ENTTEC's OCTO MK2, PIXELATOR MINI, and DIN PIXIE controllers. This guide covers verifying datasheets, configuring device settings, and setting voltage calendrier.
Préview Guide de création de protocoles personnalisés ENTTEC : Luminaires à pixels de contrôle
Apprenez à créer des protocoles de pixels LED personnalisés pour les contrôleurs ENTTEC tels que DIN PIXIE et PIXELATOR MINI grâce à ce guide complet. Réglez le volume.tage. Synchronisation et vérification des fiches techniques.
Préview Manuel d'utilisation et spécifications techniques de l'ENTTEC Phero 33
Manuel d'utilisation complet pour l'ENTTEC Phero 33, détaillant ses fonctionnalités, sa configuration, son installation, l'adressage DMX, ses spécifications techniques et les informations de commande. Comprend un tableau de correspondance DMX détaillé.
Préview Manuel d'utilisation ENTTEC OCTO MK3 : Contrôleur de pixels eDMX vers SPI
Manuel d'utilisation complet de l'ENTTEC OCTO MK3, un contrôleur de pixels eDMX vers SPI polyvalent avec mode autonome et fonctions d'overdrive. Découvrez l'installation, la configuration, la mise en réseau et le dépannage.
Préview ENTTEC PIXELATOR MINI MK2 : Manuel d’utilisation pour la commande de pixels eDMX vers SPI
Manuel d'utilisation complet du contrôleur de pixels ENTTEC PIXELATOR MINI MK2, doté de 16 ports eDMX vers SPI. Découvrez l'installation, la configuration, la mise en réseau et les fonctionnalités avancées pour un contrôle fiable de l'éclairage des pixels à distance.