Dasqua 1804-1055

Manuel d'utilisation du mètre laser 2 en 1 Dasqua 1804-1055

Modèle: 1804-1055

1. Introduction

This manual provides comprehensive instructions for the safe and effective use of your Dasqua 1804-1055 2-in-1 Laser Tape Measure. This device combines a traditional 5-meter tape measure with a 30-meter laser distance meter, featuring an OLED display for clear readings and USB charging capability. Please read this manual thoroughly before operating the device and retain it for future reference.

2. Consignes de sécurité

AVERTISSEMENT: This product contains a Class 2 laser. Improper use can result in hazardous radiation exposure. Always adhere to the following safety guidelines:

3. Produit terminéview

3.1 Composants et commandes

Familiarize yourself with the main components and control buttons of your Dasqua 2-in-1 Laser Tape Measure.

Dasqua 1804-1055 Laser Tape Measure with labeled components and buttons

Image: Diagram showing the Dasqua 1804-1055 device with labels for the OLED display, laser emission point, USB charging port, tape measure, lock button, and control buttons.

3.2 boutons de commande

Close-up of Dasqua 1804-1055 control buttons

Image : Gros plan view of the control panel on the Dasqua 1804-1055, showing the FUNC/UNITS, +/-, DIST, and CLEAR/OFF buttons.

4. Installation

4.1 Chargement de l'appareil

The Dasqua 1804-1055 is equipped with a built-in Li-ion 3.7V rechargeable battery. Before first use, ensure the device is fully charged.

Dasqua 1804-1055 with USB charging port

Image : Côté view of the Dasqua 1804-1055 showing the micro-USB charging port.

  1. Repérez le port de chargement USB sur le côté de l'appareil.
  2. Connect the provided USB cable to the device and to a standard USB power adapter (not included) or a computer USB port.
  3. L'écran OLED indiquera l'état de charge.
  4. Une fois la batterie complètement chargée, débranchez le câble USB.

Une charge complète permet d'effectuer environ 30 000 mesures.

4.2 Mise sous/hors tension

5. Mode d'emploi

5.1 Utilisation du mètre ruban

The integrated 5-meter tape measure functions like a standard tape measure.

Close-up of Dasqua 1804-1055 tape measure

Image : Gros plan view of the 2.5cm wide tape measure extending from the Dasqua 1804-1055 device, showing metric markings.

  1. Pull the tape blade out to the desired length.
  2. To lock the tape in place, slide the lock button forward.
  3. To retract the tape, slide the lock button backward and gently guide the tape back into the housing.

5.2 Utilisation du télémètre laser

The laser measure provides quick and accurate digital distance measurements up to 30 meters.

Dasqua 1804-1055 emitting a red laser beam

Image: The Dasqua 1804-1055 device with a visible red laser beam extending from its front, indicating active laser measurement.

Mesure de distance unique

  1. Allumez l'appareil.
  2. Point the laser emission point towards the target.
  3. Appuyez sur le RÉPARTITION Appuyez une fois sur le bouton pour activer le laser. Un point laser rouge apparaîtra sur la cible.
  4. Appuyez sur le RÉPARTITION button again to take the measurement. The distance will be displayed on the OLED screen.

Mesure continue (suivi)

  1. Allumez l'appareil.
  2. Appuyez sur le FUNC/UNITS button until the continuous measurement icon (often a moving line or similar) appears on the display.
  3. Appuyez sur le RÉPARTITION button once to start continuous measurement. The display will update in real-time as you move the device.
  4. Appuyez sur le RÉPARTITION button again to stop continuous measurement and hold the last reading.

Modification des unités de mesure

To switch between meters (m), feet (ft), and inches (in):

Réglage du point de référence de mesure

The device can measure from its front edge or its rear edge. This is typically indicated by an icon on the display.

Addition et soustraction de mesures

The device supports basic arithmetic operations for measurements.

  1. Take the first measurement using the RÉPARTITION bouton.
  2. Appuyez sur le +/- button once for addition (+) or twice for subtraction (-). The corresponding symbol will appear on the display.
  3. Take the second measurement. The result of the operation will be displayed.
  4. To clear the calculation, press EFFACER.

6. Entretien

7. Dépannage

ProblèmeCause possibleSolution
L'appareil ne s'allume pas.Batterie faible.Chargez l'appareil à l'aide du câble USB.
Mesures laser inexactes.Lentille laser sale ; surface de mesure instable ; point de référence incorrect.Clean the laser lens; ensure a stable measurement; verify reference point setting.
Le laser ne s'active pas.Device in incorrect mode; low battery.Ensure device is powered on and not in a non-laser mode; charge battery.
OLED display is dim or blank.Low battery; device powered off.Charge the device; power on the device.

8. Spécifications

Detailed technical specifications for the Dasqua 1804-1055 2-in-1 Laser Tape Measure.

Dasqua 1804-1055 Laser Tape Measure technical specifications diagram

Image: Detailed diagram of the Dasqua 1804-1055 with a list of technical specifications including measurement range, accuracy, laser class, operating conditions, and battery life.

FonctionnalitéSpécification
Plage de mesure laser0.05 à 30 mètres
Longueur du ruban à mesurer5 mètres
Précision de mesure+/- 3 mm
Cours de laserClasse 2
Type de laser620-690nm, <1mW
Température de fonctionnement0°C - 40°C (32°F - 104°F)
Température de stockage-20°C - 70°C (-4°F - 158°F)
Type d'affichageOLED, Multi-line (2 lines), White on Black
Type de batterieLi-ion 3.7 V
Autonomie de la batterieEnviron. 2000 mesures
Laser Auto-Off30 secondes
Arrêt automatique de l'alimentation90 secondes
Largeur de bande2.5 cm
ChargementCapacité de chargement USB
Dimensions du produit6 x 5 x 3 pouces (environ)
Poids de l'article2 livres (environ)

9. Garantie et assistance

Dasqua products are manufactured under strict quality control. This product is inspected and approved for sale by Dasqua quality control centers.

Dasqua Warranty Letter and Instruction Manual

Image: The Dasqua 1804-1055 device alongside a "Warranty Letter" and an instruction manual, indicating product quality assurance.

Dasqua takes responsibility for the quality of the product, providing a 1-year warranty against defects. Parts found to be defective may be repaired or replaced at Dasqua's sole discretion. This warranty does not apply to any product which has been subject to misuse, abuse, improper application, or which has been altered or repaired by unauthorized personnel.

For warranty claims or technical support, please contact your authorized Dasqua dealer or visit the official Dasqua website pour les coordonnées.

Documents connexes - 1804-1055

Préview Instructions pour la règle d'angle numérique Dasqua
Instructions complètes pour la règle d'angle numérique Dasqua, couvrant les fonctions, les caractéristiques, la maintenance, le dépannage et les modes de fonctionnement tels que NORMAL, CROWN et CUS.
Préview Manuel d'utilisation et spécifications du pied à coulisse numérique Dasqua
Guide complet du pied à coulisse numérique Dasqua, comprenant les instructions d'utilisation, les consignes de sécurité, les spécifications, le dépannage et les informations sur la mise au rebut. Il inclut également des informations sur l'installation et l'entretien des piles.
Préview Instructions d'utilisation du pied à coulisse numérique Dasqua IP67
Instructions complètes pour le pied à coulisse numérique Dasqua IP67, couvrant les directives de performances, l'élimination, le dépannage, les spécifications et les instructions de fonctionnement.
Préview Manuel d'instructions du pied à coulisse à vernier/à cadran Dasqua
Manuel d'instructions pour les pieds à coulisse à vernier et à cadran Dasqua, couvrant les structures, la lecture des mesures, l'utilisation courante, l'utilisation spéciale des pieds à coulisse, les précautions et le dépannage.
Préview Indicateur numérique avec codeur linéaire - Informations techniques et de sécurité
Consignes de sécurité, directives de manipulation et spécifications techniques pour la jauge indicatrice numérique DASQUA avec codeur linéaire (modèles DQ-25001, DQ-25002).
Préview Pied à coulisse numérique Dasqua IP67 : instructions et guide d'utilisation
Notice d'utilisation complète du pied à coulisse numérique Dasqua IP67. Ce guide présente les consignes de performance, les précautions de sécurité, les spécifications détaillées, les instructions d'utilisation, le remplacement des piles, le dépannage et les méthodes d'élimination appropriées pour un fonctionnement précis et sûr.