ResMed AC-CMSV-08D8

Manuel d'utilisation du système de cadre ResMed AirFit F30i

Model: AC-CMSV-08D8

1. Produit terminéview

The ResMed AirFit F30i Frame System is a component of the ResMed AirFit F30i full face CPAP mask, designed to provide comfort and freedom during CPAP therapy. This frame system features a top-of-head tube connection, which helps keep the air tubing out of the way, allowing for greater movement during sleep. It is engineered to fit various facial shapes and sizes, ensuring a secure and customized fit. The mask cushion is designed to sit under the nose, aiming to reduce discomfort and red marks on the nasal bridge.

Caractéristiques principales :

  • Designed for ResMed AirFit F30i full face CPAP mask.
  • Top-of-head tube connection for enhanced freedom of movement.
  • Compatible with various CPAP machines and accessories.
  • This frame system replacement does not include the AirFit F30i headgear.
ResMed AirFit F30i Frame System

Figure 1: The ResMed AirFit F30i Frame System, showing its minimalist design.

Explosé view of ResMed AirFit F30i Frame System components

Figure 2 : Vue éclatée view of the AirFit F30i Frame System, illustrating its individual components (without headgear).

2. Consignes de sécurité

Avertissements importants :

  • Keep the mask magnets at a safe distance of at least 6 inches (150 mm) away from implants or medical devices that may be adversely affected by magnetic interference. This warning applies to the user or anyone in close physical contact with the mask.
  • The magnets are located in the frame and lower headgear clips, with a magnetic field strength of up to 400mT. While designed to secure the mask, they may inadvertently detach during sleep.

Contre-indications :

Masks with magnetic components are contraindicated for use by patients who, or anyone in close physical contact while using the mask, have the following:

  • Implants médicaux actifs qui interagissent avec des aimants (par exemple, stimulateurs cardiaques, défibrillateurs cardioverteurs implantables (DCI), neurostimulateurs, shunts de liquide céphalo-rachidien (LCR), pompes à insuline/à perfusion).
  • Implants/objets métalliques contenant un matériau ferromagnétique (par exemple, clips d'anévrisme/dispositifs d'interruption de flux, bobines emboliques, stents, valves, électrodes, implants pour restaurer l'audition ou l'équilibre avec des aimants implantés, implants oculaires, éclats métalliques dans l'œil).

3. Installation et réglage

Proper setup and fitting are crucial for effective CPAP therapy and comfort. Ensure you have the correct cushion and frame size for your mask.

Image showing how to check CPAP mask cushion and frame size

Figure 3: Verify the size of both the cushion and the frame for optimal fit.

Instructions de montage:

  1. Hold the mask frame and cushion against your face.
  2. Pull the headgear over your head, ensuring the top-of-head connection is positioned correctly.
  3. Adjust the headgear straps to achieve a comfortable and secure seal without overtightening.
  4. Connect the CPAP tubing to the top-of-head connector.

Video 1: Demonstrates the correct method for wearing the CPAP mask, ensuring proper placement and adjustment.

Video 2: Shows the assembly and attachment of replacement headgear for the CPAP AirFit F30i mask, including clip usage.

Person wearing ResMed AirFit F30i mask, demonstrating freedom of movement

Figure 4: The top-of-head tube connection allows for freedom to switch sleep positions without dislodging the mask.

4. Operating the Mask System

Once the ResMed AirFit F30i Frame System is properly fitted and connected to your CPAP machine, it operates by delivering pressurized air through the cushion to maintain an open airway during sleep. The top-of-head tubing design minimizes facial contact and allows for various sleeping positions without interference from the hose.

Ensure the mask forms a gentle but effective seal around your nose and mouth area. If you experience air leaks, readjust the headgear straps. The magnetic clips facilitate easy attachment and detachment of the headgear from the frame.

5. Entretien et nettoyage

Regular cleaning and maintenance are essential to ensure the longevity and hygienic use of your AirFit F30i Frame System.

Instructions for daily care of ResMed AirFit frame system

Figure 5: Daily care instructions for your AirFit frame system.

Soins quotidiens:

  • Inspect for signs of deterioration and replace components as needed.
  • Wipe the outside of the foam with CPAP wipes or similar alcohol-free wipes.
  • Étalez-les à plat sur une serviette pour les laisser sécher à l'air libre.

Éviter:

  • Exposition directe au soleil.
  • Washing in a dishwasher or washing machine.
  • Using alcohol or bleach for cleaning.

6. Troubleshooting and Replacement

To maintain effective therapy, it is recommended to replace your frame system every 3 months, or sooner if signs of wear are observed.

Recommendation to replace CPAP mask frame system every 3 months

Figure 6: Recommended replacement schedule and signs indicating a need for replacement.

Signes indiquant qu'il est peut-être temps de remplacer votre système de cadre :

  • Vous constatez des fuites excessives.
  • Votre thérapie vous semble moins efficace que d'habitude.
  • Votre système de monture commence à montrer des signes d'usure (par exemple, des fissures, une décoloration, une perte d'élasticité).

If you encounter persistent issues such as discomfort, skin irritation, or difficulty achieving a proper seal, consult your healthcare provider or CPAP equipment supplier.

7. Spécifications

Dimensions du produit15.5 x 10 x 3 pouces
Poids de l'article3.84 onces
Numéro de modèleAC-CMSV-08D8
FabricantResMed
DépartementAdultes
Date de première disponibilité9er mars 2022

Documents connexes - AC-CMSV-08D8

Préview Instructions d'ajustement et guide des tailles du cadre de masque facial complet ResMed AirFit F30i
Guide étape par étape pour l'ajustement et le dimensionnement de la monture de masque facial complet ResMed AirFit F30i. Inclut les mesures pour les tailles S, Standard et L, en millimètres et en pouces.
Préview Guide des tailles de masques et de montures ResMed AirTouch F30i et AirFit F30i/X30i
Un guide complet de ResMed pour aider les utilisateurs à choisir avec précision la taille des coussins et des cadres de leurs masques CPAP AirTouch F30i et AirFit F30i/X30i pour un ajustement et un confort optimaux.
Préview ResMed AirFit F30i and AirFit X30i CPAP Mask Disinfection Guide
This guide provides essential reprocessing instructions for ResMed AirFit F30i and AirFit X30i CPAP masks intended for multi-patient use in clinical settings. It details cleaning, thermal disinfection, inspection, and reassembly procedures to ensure safe and effective mask reuse.
Préview ResMed AirFit F30i Disinfection Guide for Multi-Patient Use
Comprehensive guide for cleaning and thermal high-level disinfection of ResMed AirFit F30i and AirFit F30i Non Magnetic masks for multi-patient re-use in clinical settings.
Préview Guide de l'utilisateur Resmed AirTouch F30i et AirFit F30i
Guide d'utilisation complet pour les masques faciaux intégraux Resmed AirTouch F30i et AirFit F30i, couvrant l'ajustement, le nettoyage, la sécurité et les spécifications techniques pour la thérapie PAP.
Préview Guide des tailles de coussin et de cadre ResMed AirTouch F30i
Un guide complet de ResMed pour choisir la taille appropriée du coussin et de l'armature du masque CPAP AirTouch F30i et ainsi optimiser votre confort. Comprend des instructions de mesure et des tableaux de tailles.