1. Introduction
The Xetron STC-1000ProTH is a pre-wired digital temperature and humidity controller designed for precise environmental management. This device allows simultaneous or independent control of both temperature (heating or cooling) and humidity (humidification or dehumidification) within a specified range. It is suitable for various applications including seed fermentation, reptile habitats, incubators, greenhouses, and more.
This manual provides detailed instructions for the safe and effective use of your STC-1000ProTH controller. Please read it thoroughly before operation.
2. Consignes de sécurité
- Assurer l'alimentation voltage matches the controller's specifications (110V 10A).
- Do not immerse the controller or sensor probe in water or expose to excessive moisture.
- Always unplug the controller from the power outlet before cleaning or performing any maintenance.
- Do not exceed the maximum load capacity of 10A for the outlets.
- Tenir hors de portée des enfants.
- The controller is made of anti-flame ABS material for enhanced safety.
3. Produit terminéview et fonctionnalités
The Xetron STC-1000ProTH features a large LCD screen for clear display of current and set values, along with intuitive 3-button operation for easy programming.

Figure 3.1: Xetron STC-1000ProTH Controller, sensor, and power outlets.
Caractéristiques principales :
- Double contrôle : Manages both temperature and humidity simultaneously or independently.
- Wide Range & High Accuracy: Temperature control from 23℉ to 158℉ (-5℃ to 70℃) with ±1℉/±0.5℃ accuracy. Humidity control from 5%RH to 99%RH with ±5%RH accuracy.
- Conception pré-câblée : Includes two pre-wired outlets (Work1 for temperature, Work2 for humidity) and a 2.5-inch LCD screen for plug-and-play operation.
- Paramètres personnalisables : Supports settings for ℃/℉, temperature & humidity calibration, high/low alarm values, start-up delay, and protection time.
- Système d'alarme double : Visual (bell icon) and audible (buzzer) alerts activate if temperature or humidity exceeds set limits.
- Protection contre le retard du compresseur : Extends the service life of connected equipment by preventing rapid cycling.
- Construction durable : Made from anti-flame ABS material, compliant with CE and FCC standards.

Figure 3.2: The controller supports both humidification/dehumidification and heating/cooling functions.

Figure 3.3: Visual and audible alerts, along with compressor delay protection.
4. Contenu du colis
Vérifiez que tous les éléments sont présents dans le colis :
- 1x Xetron STC-1000ProTH Temperature and Humidity Controller
- 1x Manuel d'utilisation (ce document)
- 1x Temperature and Humidity Sensor Probe
5. Guide de configuration
5.1 Connexion du contrôleur
- Plug the main power cord of the Xetron STC-1000ProTH controller into a standard 110V AC power outlet.
- Connect the temperature and humidity sensor probe to the designated port on the controller. Ensure it is securely inserted.
- Identify the 'WORK1' outlet for temperature control and 'WORK2' for humidity control.
- Plug your heating or cooling device into the 'WORK1' outlet.
- Plug your humidifying or dehumidifying device into the 'WORK2' outlet.

Figure 5.1: Connection points for the sensor and controlled devices.

Figure 5.2: Features including the large LCD screen, 2m NTC sensor, pre-wired sockets, and safe plug.
6. Mode d'emploi
6.1 Comprendre l'affichage
The large LCD screen displays key information:
- TPV: Temperature Present Value (current temperature).
- HPV: Humidity Present Value (current humidity).
- TSV: Temperature Set Value (desired temperature).
- HSV: Humidity Set Value (desired humidity).
The display also shows icons for heating, cooling, humidifying, dehumidifying, and alarms.

Figure 6.1: Screen display with value definitions.
6.2 Basic Parameter Settings
Pour accéder au mode de réglage, maintenez enfoncée la touche ENSEMBLE button for 3 seconds until the display beeps or flashes. Use the UP et VERS LE BAS buttons to navigate through parameters. Press ENSEMBLE once to select a parameter, use UP/VERS LE BAS to adjust the value, then press ENSEMBLE again to confirm. Hold ENSEMBLE attendre 3 secondes pour quitter le mode de réglage.
Example: Setting Humidity Range (e.g., 55% to 65% RH)
- Appuyez et maintenez ENSEMBLE pendant 3 secondes pour entrer en mode de réglage.
- Utiliser UP/VERS LE BAS to navigate to the 'HS' (Humidity Start) setting.
- Presse ENSEMBLE once, then use UP/VERS LE BAS to set the value to '60' (for 60% RH). Press ENSEMBLE pour confirmer.
- Navigate to the 'HD' (Humidity Differential) setting.
- Presse ENSEMBLE once, then use UP/VERS LE BAS to set the value to '5' (for 5% RH differential). Press ENSEMBLE to confirm. This means the humidity will turn on at 55% (60-5) and turn off at 60%.
- Prise ENSEMBLE attendre 3 secondes pour quitter le mode de réglage.

Figure 6.2 : Example of setting humidity parameters (HS and HD).
6.3 Paramètres d'alarme
The controller features dual alarms for both temperature and humidity. You can set high and low alarm limits. If the measured value goes outside these limits, the controller will sound a buzzer and display a bell icon.

Figure 6.3: Audible and visual alarm indicators.
6.4 Protection contre le retard du compresseur
This feature prevents rapid cycling of connected compressors (e.g., in refrigerators or dehumidifiers), which can extend their lifespan. You can set a delay time in the parameter settings.

Figure 6.4: Compressor delay protection mechanism.
6.5 Options d'affichage à l'écran
The controller allows you to set the screen display to always remain ON. Refer to the manual's parameter list for the specific setting (e.g., 'BL' to 'O').

Figure 6.5: Option to keep the screen display continuously ON.
7. Applications typiques
The Xetron STC-1000ProTH controller is versatile and can be used in various environments requiring precise temperature and humidity control:
- Habitats des reptiles : Maintain optimal temperature and humidity levels for the health and well-being of reptiles.
- Seed Germination/Cultivation: Create ideal conditions for plant growth and seed starting in greenhouses or grow tents.
- Fermentation: Control temperature for consistent results in home brewing, yogurt making, or other fermentation processes.
- Incubateurs : Regulate temperature and humidity for successful egg incubation.
- Freezers/Refrigerators: Convert a standard refrigerator into a freezer or maintain specific storage temperatures.
- Brassage maison : Ensure precise temperature control for fermentation.

Figure 7.1: Diverse applications of the Xetron STC-1000ProTH controller.

Figure 7.2: Reptile temperature and humidity control.

Figure 7.3: Seedling temperature and humidity control.

Figure 7.4: Fermentation temperature control.

Figure 7.5: Freezer temperature control.
8. Entretien
- Nettoyage: Wipe the controller and sensor probe with a soft, dry cloth. Do not use abrasive cleaners or immerse in liquids.
- Entretien du capteur : Handle the sensor probe carefully. Avoid bending or damaging the cable. Ensure the sensor is free from dust or debris for accurate readings.
- Stockage: Lorsqu'il n'est pas utilisé, rangez la manette dans un endroit frais et sec, à l'abri de la lumière directe du soleil.
9. Dépannage
- Manette ne s'allume pas : Check if the main power plug is securely inserted into a live outlet.
- Connected Device Not Activating:
- Verify that the device is correctly plugged into the 'WORK1' (temperature) or 'WORK2' (humidity) outlet.
- Ensure the device itself is functional by plugging it directly into a wall outlet.
- Check your set parameters (TSV, HSV, differentials) to ensure the current conditions should trigger the device.
- Review alarm settings; if an alarm is active, it might prevent normal operation.
- Consider the compressor delay protection setting if applicable.
- Lectures inexactes :
- Ensure the sensor probe is clean and unobstructed.
- Verify the sensor is properly connected to the controller.
- Perform a temperature and humidity calibration if you have a reference instrument.
- Alarme qui se déclenche constamment : Adjust the high and low alarm limits to suit your desired operating range.
10. Spécifications techniques
| Spécification | Valeur |
|---|---|
| Numéro de modèle | STC-1000Pro TH |
| Vol d'entréetage | 110 V c.a. |
| Courant de charge max | 10A |
| Plage de contrôle de la température | 23 ℉ ~ 158 ℉ (-5 ℃ ~ 70 ℃) |
| Précision de la température | ±1℉ / ±0.5℃ |
| Plage de contrôle de l'humidité | 5% d'humidité relative à 99% d'humidité relative |
| Précision de l'humidité | ± 5% HR |
| Type d'affichage | Écran LCD |
| Matériel | Anti-flame ABS Plastic |
| Dimensions du produit | 7.87 x 5.91 x 2.36 inches (Controller: 2.36"L x 1.2"W x 5.5"H) |
| Poids de l'article | 14.1 onces (0.4 kilogrammes) |
| Composants inclus | Controller, User Manual, T&H Sensor Probe |
11. Garantie et support client
Xetron provides a one-year warranty for this product, covering manufacturing defects and ensuring continuous customer assistance. For technical support, troubleshooting, or warranty claims, please contact Xetron customer service through the retailer's platform or visit the official Xetron website pour les coordonnées.