The TRU COMPONENTS TC-9539292 is a robust and durable LED signal column designed for industrial applications. It provides clear visual and audible indications for various operational states. This manual provides essential information for the safe and effective installation, operation, and maintenance of your signal column.

TRU COMPONENTS TC-9539292 LED Signal Column with red and green light segments and attached power cable.

Image: TRU COMPONENTS TC-9539292 LED Signal Column. This image displays the TRU COMPONENTS TC-9539292 LED Signal Column. The column features two distinct light segments: an upper red segment and a lower green segment. A black power cable with exposed wires at the end is shown coiled next to the column, indicating its electrical connection. The base of the signal column includes a threaded section for mounting.

Consignes de sécurité

Respectez toujours les consignes de sécurité suivantes afin d'éviter les blessures et les dommages à l'appareil :

  • Assurez-vous que l'alimentation électrique est débranchée avant toute installation, maintenance ou dépannage.
  • L'installation doit être effectuée uniquement par du personnel qualifié, conformément aux codes et réglementations électriques locaux.
  • N’exposez pas l’appareil à une humidité excessive, à la poussière ou à des températures extrêmes en dehors de sa plage de fonctionnement spécifiée.
  • Vérifiez le bon voltage (24 Volts) before connecting the device.
  • Do not attempt to modify or repair the device yourself. Refer to qualified service personnel.

Configuration et installation

Follow these steps for proper installation of the signal column:

  1. Montage: The signal column features a threaded base (M2x15, Hexagonal head style) for secure mounting. Ensure the mounting surface is stable and capable of supporting the device's weight (119 grams).
  2. Câblage : Connect the signal column to a 24 Volt power supply. The cable includes multiple wires; refer to the specific wiring diagram provided with your equipment for correct connections to control the red and green LED segments and the audible alarm. Ensure all connections are secure and insulated.
  3. Considérations environnementales : Install the column in an environment that is free from excessive vibration and within the recommended operating temperature range. The material is plastic.

Mode d'emploi

The TRU COMPONENTS signal column offers both visual and audible indications:

  • Indication visuelle : The red and green LED segments can be configured for either continuous illumination or clignotant. The specific control signals for these modes will depend on your system's integration.
  • Indication sonore : The integrated sounder can produce either a tonalité continue ou un discontinuous tone (intermittent sound). Consult your system's control logic for activating these audible alerts.

The signal column is designed to integrate with industrial control systems to provide real-time status updates.

Entretien

The TRU COMPONENTS signal column is designed for durability and requires minimal maintenance. However, regular checks can extend its lifespan and ensure reliable operation:

  • Nettoyage: Periodically clean the exterior of the column with a soft, damp chiffon. N'utilisez pas de nettoyants abrasifs ou de solvants.
  • Inspection: Regularly inspect the wiring and connections for any signs of wear, damage, or loose connections. Ensure the mounting is secure.
  • Vérification des LED : Verify that both red and green LED segments illuminate correctly when activated.
  • Sounder Check: Confirm the sounder functions as expected when activated.

Débranchez toujours l’alimentation avant d’effectuer toute opération de maintenance.

Dépannage

If you encounter issues with your signal column, refer to the following common problems and solutions:

ProblèmeCause possibleSolution
Pas de lumière ni de sonNo power supply; Incorrect wiring; Faulty unitCheck power connection (24V); Verify wiring against diagram; Contact support if power and wiring are correct.
Only one LED segment illuminatesIncorrect wiring for specific segment; Faulty LED segmentCheck wiring for the non-illuminating segment; If wiring is correct, the segment may be faulty.
Sounder not workingIncorrect wiring for sounder; Faulty sounderVerify sounder wiring; If wiring is correct, the sounder may be faulty.
Fonctionnement intermittentLoose connections; Unstable power supplyCheck all wiring connections for tightness; Ensure power supply is stable.

For issues not listed above, or if solutions do not resolve the problem, please contact TRU Components customer support.

Caractéristiques

Numéro de modèleTC-9539292
FabricantCOMPOSANTS TRU
Dimensions (L x l x H)10 x 10 x 15 cm
Poids119 grammes
CouleurRouge, Vert
MatérielPlastique
Voltage24 volts
Nombre de pièces1
Type de têteHexagonal
Système de mesureMétrique
Taille du fil1/4"-20 UNC
CaractéristiquesContinuous or flashing illumination, Continuous or discontinuous sounder

Garantie et assistance

TRU Components provides a Disponibilité des pièces détachées pendant 1 an for the TC-9539292 LED Signal Column from the date of purchase.

For technical support, warranty claims, or further assistance, please contact your point of purchase or visit the official TRU Components website. Ensure you have your model number (TC-9539292) and purchase details ready when contacting support.

Documents connexes - TC-9539292

Préview Fiche technique du voyant de signalisation LED USB TRU COMPONENTS
Données techniques et instructions d'utilisation du voyant LED USB TRU COMPONENTS (article n° 2804760), doté de 7 couleurs et d'une fonction de buzzer.
Préview Mode d'emploi Alimentations LED TRU COMPONENTS TC-YCL
Guide d'utilisation et de sécurité pour les alimentations LED TRU COMPONENTS de la série TC-YCL. Inclut les instructions de montage, les spécifications techniques et les informations de sécurité.
Préview Manuel d'utilisation et spécifications techniques du transformateur LED TRU Components
Manuel d'utilisation complet et spécifications techniques pour les transformateurs LED TRU Components, y compris les numéros de modèle, les données électriques, les conditions de fonctionnement et les consignes de sécurité pour les applications d'éclairage LED intérieur.
Préview Données techniques et de sécurité des alimentations sur rail DIN TRU Components
Consignes de sécurité complètes, utilisation prévue, explications des symboles et spécifications techniques pour les alimentations sur rail DIN TRU Components, y compris les numéros de modèle et les paramètres de fonctionnement.
Préview TRU COMPONENTS Rail DIN Voedingen Gebruiksaanwijzing et Spécifications
Spécifications techniques et spécifications techniques pour l'alimentation sur rail DIN de TRU COMPONENTS. Suivez les instructions d'installation, les informations détaillées et les modèles pour diverses utilisations.
Préview Alimentation sur rail DIN TRU COMPONENTS - Manuel d'utilisation et spécifications
Instructions d'utilisation complètes et spécifications techniques des alimentations sur rail DIN TRU COMPONENTS, couvrant la sécurité, l'installation et les données produit détaillées. Inclut les numéros de modèle, les caractéristiques électriques, les dimensions et les consignes de sécurité.