RCYAGO BLE-9909

Manuel d'utilisation

RCYAGO BLE-9909 Smart Bluetooth pH/TDS/EC/Salinity/Temperature Tester

Model: BLE-9909 | Brand: RCYAGO

1. Introduction

The RCYAGO BLE-9909 is a multi-parameter smart tester designed for precise measurement of pH, Total Dissolved Solids (TDS), Electrical Conductivity (EC), Salinity, and Temperature. This device integrates Bluetooth connectivity, allowing seamless data synchronization with the YINMIK mobile application for enhanced data management and analysis. It is suitable for various applications including domestic drinking water, hydroponics, laboratory testing, and aquariums.

RCYAGO BLE-9909 Smart Tester in use, measuring water in a glass.

Figure 1: RCYAGO BLE-9909 Smart Tester in operation.

2. caractéristiques du produit

  • Mesure multiparamètre : Measures pH, TDS (ppm), EC (conductivity), Salinity (ppt), and Temperature.
  • Connectivité Bluetooth : Compatible with the YINMIK mobile application for real-time data transmission and control.
  • Cloud-Based Data Management: Enables easy saving, management, and sharing of test data, preventing data loss.
  • Calibrage automatique : Features a 5-point calibration method for pH (Asian standard: pH 4.00, pH 6.86, pH 9.18; EU standard: pH 7.00, pH 10.01) ensuring high accuracy.
  • High Sensitivity Glass Probe: Provides a full measurement range of 0-14 pH with 0.01 pH resolution.
  • Affichage complet : Large LCD screen displays multiple parameters simultaneously. App control allows for backlight adjustment.
  • Customizable Limits: The mobile application allows setting upper and lower limits for pH and EC. Abnormal values are highlighted in red.

3. Composants du produit

Familiarize yourself with the components of your BLE-9909 tester:

Explosé view of RCYAGO BLE-9909 showing components like battery, display, keys, immersion line, protective cap, and high-precision probe.

Figure 2 : Vue éclatée view of the BLE-9909 tester and its components.

  • 3*1.5V Button Battery: Source d'alimentation de l'appareil.
  • Affichage rétroéclairé : LCD screen for reading measurements.
  • Data Hold/Temperature Unit Conversion Key: Button to hold readings or switch temperature units.
  • Function Conversion/Calibration Key: Button to switch measurement modes or initiate calibration.
  • Touche MARCHE/ARRÊT : Bouton d'alimentation.
  • Immersion Line: Indicates the minimum immersion depth for accurate readings.
  • Capuchon de protection : Covers and protects the electrodes when not in use.
  • Sonde de haute précision : Contains the sensors for measurement.
Close-up of the BLE-9909 electrodes, showing TDS/EC/Salinity sensor, External Reference, Temperature Sensor, and Glass PH Sensor.

Figure 3 : Détaillé view of the BLE-9909 electrodes.

  • TDS/EC/Salinity Sensor: Measures Total Dissolved Solids, Electrical Conductivity, and Salinity.
  • External Reference: Reference electrode for stable measurements.
  • Capteur de température : Measures the temperature of the solution.
  • Glass PH Sensor: High-sensitivity sensor for pH measurements.

4. Installation

4.1 Installation de la batterie

  1. Unscrew the battery compartment cap at the top of the device (refer to Figure 2).
  2. Insert three 1.5V button batteries, ensuring correct polarity.
  3. Securely screw the battery compartment cap back on.

4.2 Mobile App Connection (YINMIK App)

The BLE-9909 connects to your smartphone via Bluetooth for advanced features and data management.

  1. Download the "YINMIK" mobile application from your device's app store (iOS App Store or Google Play Store).
  2. Assurez-vous que Bluetooth est activé sur votre smartphone.
  3. Turn on the BLE-9909 tester by pressing the "ON/OFF" key.
  4. Open the YINMIK app. The app will automatically search for and connect to the BLE-9909 device.
  5. Once connected, the app will display real-time measurement data.
RCYAGO BLE-9909 connected via Bluetooth to a smartphone displaying the YINMIK app interface.

Figure 4: Bluetooth data synchronization with the YINMIK mobile app.

5. Mode d'emploi

5.1 Prise de mesures

  1. Retirez le capuchon de protection de l'électrode.
  2. Rincez l'électrode à l'eau distillée et séchez-la délicatement en la tamponnant avec un mouchoir propre.
  3. Immerse the electrode into the solution to be tested, ensuring the immersion line is covered.
  4. Gently stir the solution and wait for the reading to stabilize on the LCD screen.
  5. Read the displayed values. The device will show pH, TDS/EC/Salinity, and Temperature.
  6. Après la mesure, rincez soigneusement l'électrode à l'eau distillée et remettez le capuchon de protection.

5.2 Changement de mode de mesure

Press the "MODE/CAL" key to cycle through different measurement parameters (pH, TDS, EC, Salinity). The active parameter will be indicated on the display.

5.3 Data Hold and Temperature Unit Conversion

Press the "HOLD/TEMP" key to hold the current reading on the display. Press it again to release. Long-press the "HOLD/TEMP" key to switch between Celsius (°C) and Fahrenheit (°F) temperature units.

6. Étalonnage

Regular calibration ensures the accuracy of your pH measurements. The BLE-9909 supports a 5-point pH calibration.

6.1 Required Calibration Solutions

  • Asian Standard: pH4.00, pH6.86, pH9.18
  • Norme UE : pH 7.00, pH 10.01

6.2 Procédure d'étalonnage

  1. Prepare the calibration buffer solutions (e.g., pH 6.86, pH 4.00, pH 9.18 for Asian standard).
  2. Turn on the tester and ensure it is in pH measurement mode.
  3. Rincez l'électrode avec de l'eau distillée et séchez-la.
  4. Immerse the electrode into the first calibration solution (e.g., pH 6.86).
  5. Press and hold the "MODE/CAL" key until "CAL" appears on the display. The device will automatically recognize the buffer solution.
  6. Wait for the reading to stabilize and for the device to confirm calibration for that point.
  7. Remove the electrode, rinse with distilled water, and blot dry.
  8. Repeat steps 4-6 for the remaining calibration solutions in sequence.
  9. Once all points are calibrated, the device will automatically exit calibration mode.

Note: For best accuracy, calibrate regularly, especially after prolonged storage or if readings appear inconsistent.

7. Data Management and App Features

The YINMIK mobile application provides comprehensive data management and additional control features.

  • Affichage des données en temps réel : View all measured parameters simultaneously on your phone screen.
  • Enregistrement des données : Automatically save measurement data to the cloud, accessible anytime.
  • Données historiques concernantview: Browse past measurements, including time and date stamps.
  • Alarmes personnalisables : Set upper and lower limits for pH and EC. The app will display values in red if they exceed these limits (see Figure 5).
  • Contrôle du rétroéclairage : Adjust the backlight of the device's LCD screen directly from the app.
  • Partage de données : Easily share your test results.
YINMIK app interface showing customizable pH and EC limits, with a red indicator for values exceeding the set range.

Figure 5: Setting custom measurement limits within the YINMIK app.

Multiple screenshots of the YINMIK app showing full display of readings, product parameter settings, calibration records, and automatic data storage.

Figure 6 : Plusview of YINMIK app features including data display, settings, and historical records.

8. Entretien

8.1 Electrode Cleaning

After each use, rinse the electrode thoroughly with distilled or deionized water to prevent contamination and buildup. Do not wipe the glass bulb, as this can cause static electricity and damage the sensor. Gently blot dry with a lint-free tissue.

8.2 Stockage

Always replace the protective cap after use. Ensure the sponge inside the cap remains moist with a few drops of pH storage solution or 3M KCl solution to keep the electrode hydrated. Never store the electrode dry or in distilled water, as this can shorten its lifespan.

8.3 Remplacement de la batterie

When the display becomes dim or the device fails to power on, replace the batteries as described in Section 4.1.

9. Dépannage

Problème Cause possible Solution
Lectures inexactes Electrode not calibrated; dirty electrode; expired calibration solution; damaged electrode. Calibrate the device (Section 6); clean the electrode (Section 8.1); use fresh calibration solutions; replace electrode if damaged.
L'appareil ne s'allume pas Piles faibles ou mortes ; installation incorrecte des piles. Replace batteries (Section 8.3); ensure correct battery polarity (Section 4.1).
Problèmes de connexion Bluetooth Bluetooth off on phone; app not open; device too far from phone; interference. Ensure Bluetooth is on; open YINMIK app; bring device closer to phone; restart both device and app.
Les lectures fluctuent excessivement Electrode not fully immersed; air bubbles on electrode; solution not stable; damaged electrode. Ensure immersion line is covered; gently tap electrode to remove bubbles; wait for solution to stabilize; replace electrode if necessary.

10. Spécifications

Paramètre Valeur
Numéro de modèle BLE-9909
Marque RCYAGO
Dimensions 23.8 x 8 x 5.21 cm
Poids 168 g
Plage de mesure du pH pH 0.00 - 14.00
Résolution du pH PH 0.01
Plage de mesure de la température Typically 0-60°C
Source d'énergie 3 x 1.5V Button Batteries
Connectivité Bluetooth (YINMIK Mobile App)

11. Garantie et assistance

For warranty information, technical support, or service inquiries, please contact RCYAGO customer service through the official website or your point of purchase. Please have your model number (BLE-9909) and purchase date available when contacting support.

Fabricant: RCYAGO

First Available Date on Amazon.es: 24 décembre 2021

Documents connexes - BLE-9909

Préview Manuel d'instructions de l'analyseur d'oxygène dissous intelligent de type stylo DO-9100
Ce document fournit des instructions pour l'analyseur d'oxygène dissous intelligent de type stylo DO-9100, couvrant ses fonctionnalités, ses paramètres techniques, son fonctionnement, sa maintenance et son dépannage.
Préview Manuel d'utilisation de la minuterie d'eau double RCYAGO SGW07
Manuel d'utilisation complet du programmateur d'arrosage double RCYAGO SGW07. Découvrez le produit ci-dessous.view, spécifications, installation, programmes d'arrosage automatique, arrosage manuel, délai de pluie, dépannage et état de la batterie pour votre système d'irrigation de jardin.
Préview YINNIK BLE-9909 Bluetooth Water Quality Tester Instruction Manual
Comprehensive instruction manual for the YINNIK BLE-9909 Bluetooth 5-in-1 Water Quality Tester, covering operation, calibration, features, and specifications.
Préview Multiparamètre Portable YINMIK BLE-9909 Bluetooth 5*1 : Spécifications Techniques
Le YINMIK BLE-9909 est un testeur multiparamètre portable avec connectivité Bluetooth, conçu pour mesurer avec précision le pH, la conductivité, le TDS, la salinité et la température. Idéal pour les secteurs pharmaceutique, agroalimentaire et environnemental, il garantit des résultats fiables. Ce document détaille ses spécifications techniques et son contenu d'emballage.
Préview Testeur de qualité de l'eau Bluetooth 7 en 1 YINMIK BLE-C600 : instructions et spécifications
Guide complet pour le testeur de qualité de l'eau Bluetooth 7 en 1 YINMIK BLE-C600, couvrant la configuration, le fonctionnement, l'étalonnage, les fonctionnalités et les informations de garantie.
Préview Yieryi BLE-C600 7-in-1 Bluetooth Water Quality Tester - User Manual
Comprehensive user manual for the Yieryi BLE-C600, a 7-in-1 Bluetooth water quality tester measuring pH, EC, TDS, Salinity, S.G, and Temperature. Features APP control for data logging and analysis.