1. Introduction
The SKYRC T100 is a twin-channel balance charger designed for various battery chemistries. It features two independent charging circuits, allowing simultaneous charging of different battery types and configurations. This charger is suitable for LiPo, LiFe, LiIon, LiHV, NiMH, NiCd, and Pb batteries, offering a maximum charging power of 100W (50W per channel) and a charging current of up to 5A.
Its compact design includes convenient front-loading balance and XT60 ports, enhancing ease of use and safety.
2. Consignes de sécurité
Read all instructions and warnings carefully before use. Failure to do so may result in property damage, personal injury, or death.
- Ne laissez jamais le chargeur sans surveillance pendant son fonctionnement.
- Ensure the charger is connected to an AC 100-240V power source only.
- Ne tentez pas de recharger des batteries endommagées ou gonflées.
- Always use the correct battery type and cell count settings for your battery. Incorrect settings can cause fire or explosion.
- Chargez les batteries dans un endroit à l'abri du feu, loin des matériaux inflammables.
- Conservez le chargeur à l'abri de l'humidité, de la chaleur et de la lumière directe du soleil.
- Do not short-circuit the charging outputs.
- Tenir hors de portée des enfants.
- Débranchez l’alimentation électrique lorsque vous ne l’utilisez pas.
3. caractéristiques du produit
- Dual-Channel Charging: Two independent circuits for simultaneous charging of different battery types and configurations.
- Prise en charge de plusieurs chimies : Compatible with LiPo, LiFe, LiIon, LiHV (2-4 cells), NiMH, NiCd (6-8 cells), and Pb (6/12V) batteries.
- Integrated XT60 Connectors: Embedded XT60 ports for convenient and secure connection, preventing reverse polarity.
- Vol élevétage Précision : Affiche le volume de la batterietage with three decimal places for precise monitoring during charging and measurement.
- AGM & Cold Charge Modes: Supports charging of Absorbent Glass Mat (AGM) batteries and allows charging of Pb batteries at low temperatures.
- Conception compacte : Space-saving form factor with front-loading ports.
- Minuterie de sécurité : Adjustable safety timer (1-720 minutes & OFF) to prevent overcharging.
Illustration 3.1 : Avant view of the SKYRC T100 Dual Balance Charger, showing the LCD display, control buttons, and dual charging ports with XT60 connectors.
Image 3.2: Illustration highlighting the multi-purpose charging capabilities and compact size of the SKYRC T100 charger, indicating 5A and 50W per channel.
Image 3.3: The SKYRC T100 charger with two batteries connected, demonstrating its twin-channel charging feature. The display shows charging status for both channels A and B.
Image 3.4: Close-up of the SKYRC T100's LCD display, showing battery voltage with three decimal places, indicating high measurement accuracy.
Image 3.5: The SKYRC T100 charger depicted in a cold, snowy environment, illustrating its capability to charge PB batteries using AGM and Cold Charge modes at low temperatures.
Image 3.6 : Gros plan view of the embedded XT60 battery connectors on the SKYRC T100 charger, designed for secure and convenient battery connection.
4. Contenu du colis
- 1x SKYRC T100 Dual Balance Charger
- Cordon d'alimentation 1x
- Manuel d'instructions (ce document)
5. Installation
- Déballer: Retirez soigneusement le chargeur et tous les accessoires de l'emballage.
- Connexion électrique : Connect the supplied AC power cord to the charger's AC input port and then plug it into a suitable AC 100-240V wall outlet. The charger will power on, and the LCD display will illuminate.
- Connexion de la batterie : For each battery you wish to charge, connect its main power lead to the XT60 port (A or B) and its balance lead (if applicable) to the corresponding balance port (2-4S) on the charger. Ensure correct polarity.
6. Mode d'emploi
The SKYRC T100 features four control buttons: BATT/PROG Stop, DEC STATUS (left arrow), INC STATUS (right arrow), and ENTRER Démarrer.
6.1 Navigation dans le menu
- Utilisez le DEC STATUS et INC STATUS boutons permettant de parcourir les options du menu ou de modifier les valeurs.
- Presse ENTRER Démarrer pour confirmer une sélection ou accéder à un sous-menu.
- Presse BATT/PROG Stop to go back to the previous menu or stop an ongoing process.
6.2 Charging Procedure (General)
- Sélectionnez la chaîne : The charger will typically display information for both channels. Use the arrow buttons to highlight the channel (A or B) you wish to configure.
- Sélectionnez le type de batterie : Presse ENTRER Démarrer to enter the battery type selection. Use the arrow buttons to choose the correct battery chemistry (e.g., LiPo, NiMH, Pb) and press ENTRER Démarrer pour confirmer.
- Set Charge Mode: Select the desired charge mode (e.g., Balance Charge, Fast Charge, Storage, Discharge for Lithium batteries; Charge for NiMH/NiCd/Pb).
- Ajuster les paramètres : Set the charge current (e.g., 0.1A-5.0A) and cell count/voltage (for Lithium batteries) using the arrow buttons. Ensure these settings match your battery's specifications.
- Commencer à charger : Une fois tous les paramètres définis, appuyez et maintenez enfoncé le ENTRER Démarrer button for a few seconds to initiate the charging process. The charger will perform a pre-charge check.
- Surveiller les progrès : The LCD will display real-time charging information, including current, voltage, and charged capacity.
- Arrêtez de charger : To stop charging at any time, press the BATT/PROG Stop button. The charger will automatically stop when the battery is fully charged.
6.3 Specific Charging Modes
- Charge d'équilibre (LiPo/LiFe/LiIon/LiHV) : Recommended for Lithium batteries to ensure all cells are charged to the same voltage, extending battery life. Requires balance lead connection.
- Charge (NiMH/NiCd/Pb): Standard charging mode for these battery types.
- AGM Mode (Pb Battery): Select this mode for Absorbent Glass Mat (AGM) lead-acid batteries.
- Cold Charge Mode (Pb Battery): Use this mode when charging Pb batteries in low-temperature environments.
7. Entretien
- Nettoyage: Regularly clean the charger's exterior with a soft, dry cloth. Do not use solvents or abrasive cleaners.
- Ventilation: Veillez à ce que les orifices de ventilation du chargeur soient exempts de poussière et de débris afin d'éviter toute surchauffe.
- Stockage: Rangez le chargeur dans un endroit frais et sec, à l'abri de la lumière directe du soleil et de l'humidité lorsqu'il n'est pas utilisé.
- Inspection des câbles : Periodically inspect all cables and connectors for signs of wear or damage. Replace damaged components immediately.
8. Dépannage
- Charger does not power on:
- Check if the AC power cord is securely connected to both the charger and the wall outlet.
- Vérifiez que la prise murale est alimentée.
- Charging does not start:
- Ensure the battery is correctly connected to the charger (main and balance leads, if applicable).
- Verify that the battery type and cell count settings match the connected battery.
- Check for any error messages on the LCD display and refer to the manual for their meaning.
- Ensure you have pressed and held the ENTRER Démarrer button to initiate charging.
- Message d'erreur affiché :
- Common errors include 'Connection Break', 'Cell Error', 'Voltage Error'. Consult the full manual for specific error code interpretations and solutions.
- Disconnect and reconnect the battery, then restart the charging process.
- Battery not fully charged:
- Check the set charge current; a lower current will take longer.
- Ensure the safety timer is not set too short.
- Verify the battery's health; a degraded battery may not reach full capacity.
9. Spécifications
Image 9.1: Diagram showing the dimensions of the SKYRC T100 charger: 90mm width, 100mm depth, and 127mm height.
| Spécification | Valeur |
|---|---|
| Matériau du boîtier | Plastique |
| Taille du boîtier | 90x100x127mm |
| Poids | 500g |
| Type d'affichage | 2x16 LCD (Blue Backlight) |
| Vol d'entréetage | 100-240 V CA |
| Charger Wattage | 50 W x 2 (Total 100 W) |
| Plage de courant de charge | 0.1A - 5.0A |
| Solde actuel | 300mA / cellule |
| Battery Types/Cells (LiPo/LiIon/LiFe/LiHV) | Cellules 2-4 |
| Types de batteries/piles (NiMH/NiCd) | Cellules 6-8 |
| Types de piles/cellules (Pb) | 6 V / 12 V |
| Vol de chargetage (LiPo) | 4.18-4.25V/cellule |
| Vol de chargetage (LiFe) | 3.58-3.7V/cellule |
| Vol de chargetage (LiIon) | 4.08-4.2V/cellule |
| Vol de chargetaget (LiHV) | 4.25-4.35V/cellule |
| Vol de coupure de déchargetage (LiPo) | 3.0-3.3V/cellule |
| Vol de coupure de déchargetage (LiFe) | 2.6-2.9V/cellule |
| Vol de coupure de déchargetage (LiIon) | 2.9-3.2V/cellule |
| Vol de coupure de déchargetaget (LiHV) | 3.1-3.4V/cellule |
| Minuterie de sécurité | 1-720 minutes & OFF |
| Procédé de charge | CC/CV for Lithium batteries; CC/CV and float charge for PB batteries. |
10. Garantie et assistance