1. Introduction
The AMX NX-3200 NetLinx NX Integrated Controller is designed for advanced control and automation in various environments, including large lecture halls, boardrooms, media rooms, and integrated homes. It offers robust security features, such as NX Master Security firmware and Dual NIC, to ensure secure communication over computer networks, meeting IT industry security standards. This manual provides essential information for the proper setup, operation, maintenance, and troubleshooting of your NX-3200 controller.
Figure 1: AMX NX-3200 NetLinx NX Integrated Controller, showing the rear panel and side view.
2. Consignes de sécurité
Before operating the AMX NX-3200, read and understand all safety instructions. Retain this manual for future reference.
- Veillez à installer l'appareil dans un endroit bien ventilé afin d'éviter toute surchauffe.
- Only use the power supply provided or specified by AMX.
- N’exposez pas l’appareil à l’humidité, à la pluie ou à des températures extrêmes.
- Évitez de placer des objets lourds sur l'appareil.
- Confiez toute intervention à un technicien qualifié. N'essayez pas d'ouvrir ou de réparer l'appareil vous-même.
3. Contenu du colis
Vérifiez que tous les éléments sont présents dans le colis :
- AMX NX-3200 NetLinx NX Integrated Controller
- Alimentation (12 V CC)
- Matériel de montage (le cas échéant)
- Documentation (ce manuel, guide de démarrage rapide)
4. Produit terminéview
4.1 Panneau avant
Figure 2: Front Panel of the AMX NX-3200.
The front panel of the NX-3200 provides status indicators and a TO PC port for direct connection. Key components include:
- TO PC (USB) Port: For direct connection to a computer for initial configuration and firmware updates.
- LED LIEN/ACT : Indicates network link status and activity.
- LED D'ÉTAT : Displays the operational status of the controller.
- LED DE SORTIE : Indicates output activity.
- DEL D'ENTRÉE : Indicates input activity.
- ICS LAN LED: Status indicator for the ICS LAN connection.
- SERIAL (TX/RX) LEDs: Indicators for transmit and receive activity on serial ports 1-8.
- RELAYS LEDs: Status indicators for relay outputs 1-8.
- IR/SERIAL LEDs: Indicators for IR/Serial ports 1-8.
- Voyants d'E/S : Status indicators for I/O ports 1-8.
4.2 Panneau arrière
Figure 3: Rear Panel of the AMX NX-3200.
The rear panel provides all necessary connections for integrating the NX-3200 into your system. These include:
- RS-232 Ports (1-8): For serial communication with various devices.
- RS-232/422/485 Ports (1-8): Configurable serial ports for flexible communication.
- Relay Ports (1-8): For controlling external devices requiring contact closure.
- I/O Ports (1-8): General purpose input/output ports.
- IR/Serial Ports (1-8): For infrared control or additional serial communication.
- ICS LAN Port: Port Ethernet pour la connectivité réseau et le contrôle.
- LAN 10/100 Port: Additional Ethernet port for network connectivity, supporting Dual NIC functionality.
- USB Ports (Type A and B): For connecting USB devices or for direct PC connection.
- PWR (12VDC) Input: Connecteur d'entrée d'alimentation.
- CONFIG Button: For system configuration and reset functions.
5. Installation
5.1 Montage du contrôleur
The NX-3200 is designed for rack mounting or placement on a flat surface. Ensure adequate ventilation around the unit.
- For rack mounting, secure the controller using appropriate rack ears and screws (sold separately or included in package).
- When placing on a surface, ensure it is stable and free from obstructions to airflow.
5.2 Connexion de l'alimentation
- Connect the provided 12VDC power supply to the PWR input on the rear panel.
- Branchez le bloc d'alimentation sur une prise électrique appropriée.
- The controller will power on automatically. Observe the STATUS LED on the front panel.
5.3 Connexions réseau
The NX-3200 features Dual NIC for enhanced network security and flexibility.
- ICS LAN: Connect an Ethernet cable from your network switch or router to the ICS LAN port for control network communication.
- LAN 10/100: Connect an Ethernet cable to the LAN 10/100 port for a secondary network connection, if required for specific applications or network segmentation.
5.4 Connecting Control Devices
Connect your AV equipment, HVAC systems, lighting, and other devices to the appropriate ports on the rear panel.
- Périphériques série : Use RS-232, RS-422, or RS-485 ports as needed. Refer to the device's documentation for wiring requirements.
- Relay Devices: Connect devices requiring contact closure to the Relay ports.
- I/O Devices: Connect sensors or other input/output devices to the I/O ports.
- Émetteurs IR : Connect IR emitters to the IR/Serial ports for controlling IR-controlled equipment.
5.5 Configuration initiale
Initial configuration is typically performed using AMX programming software via the TO PC USB port or over the network.
- Connect a computer to the TO PC USB port on the front panel using a standard USB cable.
- Install the necessary AMX software (e.g., NetLinx Studio) on your computer.
- Follow the software instructions to discover the controller and upload your control program.
- Alternatively, if the controller has a default IP address or is configured for DHCP, it can be accessed over the network.
6. Utilisation du contrôleur
6.1 Comprendre les indicateurs LED
The front panel LEDs provide visual feedback on the controller's status and activity:
- LED D'ÉTAT :
- Vert uni : Fonctionnement normal.
- Vert clignotant : Booting up or performing a task.
- Rouge uni : Error or fault condition.
- LED LIEN/ACT :
- Vert uni : Network link established.
- Vert clignotant : Activité réseau.
- Other TX/RX, RELAYS, IR/SERIAL, and I/O LEDs illuminate to indicate data transmission, reception, or active states on their respective ports.
6.2 Fonctionnement de base
Once configured and programmed, the NX-3200 operates autonomously based on the loaded control program. User interaction typically occurs through connected control interfaces (e.g., touch panels, keypads, web interfaces) that communicate with the controller.
- Ensure all controlled devices are powered on and connected correctly.
- Use your programmed control interface to send commands to the NX-3200, which then executes the corresponding actions (e.g., turning on a projector, adjusting volume, closing blinds).
6.3 Communication sécurisée
The NX-3200 supports NX Master Security firmware for secure communication. Ensure your network infrastructure and programming leverage these features for enhanced data protection, especially in enterprise and government environments.
7. Entretien
7.1 Nettoyage
- Débranchez l’alimentation avant le nettoyage.
- Utilisez un chiffon doux et sec pour essuyer l'extérieur de l'appareil.
- N’utilisez pas de nettoyants liquides ni d’aérosols, car ils pourraient endommager l’appareil.
- Veillez à ce que les ouvertures de ventilation restent dégagées de poussière et de débris.
7.2 mises à jour du micrologiciel
Periodically check the AMX website for firmware updates. Keeping your controller's firmware up-to-date ensures optimal performance, security, and access to new features.
- Download the latest firmware from the official AMX support portal.
- Follow the instructions provided with the firmware update package for installation, typically using AMX programming software.
8. Dépannage
If you encounter issues with your NX-3200, refer to the following common problems and solutions:
| Problème | Cause possible | Solution |
|---|---|---|
| Le contrôleur ne s'allume pas. | No power, faulty power supply, or loose connection. |
|
| STATUS LED is solid red. | Erreur ou dysfonctionnement du système. |
|
| Aucune connexion réseau. | Incorrect cable, network configuration issue, or switch problem. |
|
| Controlled device not responding. | Incorrect wiring, incorrect programming, or device fault. |
|
8.1 Réinitialisation d'usine
A factory reset will erase all custom configurations and programming, restoring the controller to its default settings. Use this as a last resort.
- Disconnect power from the NX-3200.
- Appuyez et maintenez enfoncé le CONFIGURATION bouton sur le panneau arrière.
- While holding the CONFIG button, reconnect power.
- Continue holding the CONFIG button until the STATUS LED changes color or flashes in a specific pattern (refer to AMX documentation for exact sequence), then release.
- The controller will reboot with factory default settings.
9. Spécifications
Technical specifications for the AMX NX-3200 NetLinx NX Integrated Controller:
| Fonctionnalité | Détail |
|---|---|
| Numéro de modèle | NX-3200 |
| Dimensions du produit | 9.1 x 17 x 1.8 pouces |
| Poids de l'article | 6.08 livres |
| Puissance d'entrée | 12VDC (via external power supply) |
| Ports série | 8x RS-232, 8x RS-232/422/485 (configurable) |
| Ports relais | 8x (contact closure) |
| Ports d'E/S | 8x (general purpose) |
| Ports IR/série | 8x |
| Ports Ethernet | 1x ICS LAN, 1x LAN 10/100 (Dual NIC) |
| Ports USB | Type A, Type B (TO PC) |
| Micrologiciel | NX Master Security firmware |
| Fabricant | Harman International Industries, Inc |
10. Garantie et assistance
For warranty information and technical support, please refer to the official AMX website or contact your authorized AMX dealer.
- AMX Official Website: www.amx.com
- Support technique : Contact information can be found on the AMX webSection d'assistance du site.
- Gardez à portée de main votre reçu d'achat et le numéro de série du produit lorsque vous contactez le service client.