CAPTEUR INTELLIGENT AS8906

SMART SENSOR AS8906 Handheld NO2 Gas Leak Detector User Manual

Modèle: AS8906

1. Introduction

This manual provides instructions for the safe and effective operation of the SMART SENSOR AS8906 Handheld NO2 Gas Leak Detector. This device is designed for detecting Nitrogen Dioxide (NO2) gas concentrations in various environments. Please read this manual thoroughly before using the product.

1.1 Consignes de sécurité

2. Produit terminéview

2.1 Contenu du paquet

Le forfait standard comprend les éléments suivants :

Standard package contents of the SMART SENSOR AS8906 gas detector, including the device, carry case, charger, and documentation.

Figure 2.1 : Contenu standard de l'emballage.

2.2 Composants de l'appareil

Familiarize yourself with the main components of the AS8906 detector:

Devant view of the SMART SENSOR AS8906 NO2 gas detector with labeled components: High sensitive sensor, sampling pump connecting port, LCD screen, Down button, Up button, Sound alarm, Charging port, Light alarm, Power on/off button, Enter button.

Figure 2.2 : Face avant view and labeled components of the AS8906 detector.

2.3 Dimensions

The AS8906 detector features a compact design for portability.

Côte à côte view of the SMART SENSOR AS8906 NO2 gas detector showing its dimensions: 120mm height, 64.5mm width, and 38.3mm depth.

Figure 2.3 : Dimensions de l'appareil.

Dimensions : 120.2 mm (hauteur) x 64.5 mm (largeur) x 38.3 mm (profondeur).

A person's hand placing the compact SMART SENSOR AS8906 NO2 gas detector into a jeans pocket, illustrating its portability.

Figure 2.4: The compact size allows for easy portability.

3. Installation

3.1 Chargement de l'appareil

The AS8906 detector is powered by a built-in 3.7V Li-battery. Before first use, ensure the device is fully charged.

  1. Locate the charging port at the bottom of the device.
  2. Connectez le câble USB fourni au port de chargement.
  3. Connect the other end of the USB cable to the charging adapter.
  4. Plug the charging adapter into a standard power outlet.
  5. The battery indicator on the LCD screen will show charging status. A full charge typically provides up to 12 hours of continuous operation.
Gros plan view of the bottom of the SMART SENSOR AS8906 NO2 gas detector, highlighting the battery charging port.

Figure 3.1 : Emplacement du port de chargement.

The SMART SENSOR AS8906 NO2 gas detector connected to its charging adapter and USB cable.

Figure 3.2: Gas detector with recharge adapter.

3.2 Connexion du SampPompe à fil (en option)

The optional sampling pump (AS8930) is designed to assist the gas detector in environments with limited access or poor air circulation. It does not operate independently and requires power from the gas detector.

  1. Alignez le sampling pump with the gas detector's sampling pump connecting port.
  2. Securely attach the sampling pump to the gas detector using the two closed-type screws. Ensure a tight connection to avoid poor contact.
  3. Connect the soft rubber tube (500mm long) to the nozzle of the samppompe à eau.
  4. Important: Do not connect any other voltage power supply to the sampling pump to prevent damage.
Composants du sampling pump accessory, including the pump unit, user manual, warranty card, soft rubber tube, and color paper box.

Figure 3.3 : Sampling pump and accessories.

4. Fonctionnement

4.1 Mise sous/hors tension

4.2 Comprendre l'affichage

The high-density digital LCD screen displays real-time gas concentration values, battery status, and other operational indicators. The backlight function allows for use in dark areas.

4.3 fonctions d'alarme

The device features high and low alarm functions with three alert methods: sound, light, and vibration. Alarm values are adjustable.

4.4 Adjusting Alarm Values

Refer to the on-screen menu for adjusting high and low alarm thresholds. Use the Up et Vers le bas buttons to navigate and change values, and the Entrer bouton pour confirmer.

4.5 Using the Sampling Pompe

Quand le sampling pump is connected, it will draw air into the detector, allowing for gas concentration measurement in remote or confined spaces. The air flow velocity is approximately 0.5 cubic inches per hour, with a maximum gas sample collecting distance of about 50 feet.

5. Entretien

5.1 Entretien de la batterie

5.2 Nettoyage

5.3 Étalonnage

The device comes with a calibration certificate. For optimal accuracy and compliance, periodic professional calibration is recommended. Refer to the manufacturer or authorized service centers for calibration services.

6. Dépannage

If you encounter issues with your AS8906 detector, refer to the following common problems and solutions:

ProblèmeCause possibleSolution
L'appareil ne s'allume pas.Batterie faible ou déchargée.Charge the device using the provided adapter and USB cable.
Lectures inexactes.Sensor contamination or need for calibration.Ensure the sensor area is clean. Consider professional calibration if readings remain inconsistent.
Alarm not sounding/lighting/vibrating.Alarm settings configured incorrectly or disabled.Check alarm settings in the device menu. Ensure volume and vibration are enabled.
Sampling pump not working.Poor connection to the detector or pump malfunction.Assurez-vous que le sampling pump is securely attached with screws. Verify the detector is powered on.

Si le problème persiste après avoir essayé ces solutions, contactez le service client pour obtenir de l'aide supplémentaire.

7. Spécifications

7.1 Spécifications du détecteur

FonctionnalitéDétail
MarqueCAPTEUR INTELLIGENT
ModèleAS8906
Type de gazDioxyde d'azote (NO2)
Plage de mesure0 à 20 ppm
Résolution0.1 XNUMX ppm
Principe de fonctionnementCapteur électrochimique
Type d'alarmeSound, Light, Vibration (adjustable values)
Niveau sonore d'alarmeJusqu'à 80 dB
Température de fonctionnement-10~50°C
Humidité de fonctionnement15~95% RH (standard)
Source d'énergie3.7V Li-battery (Built-in)
Courant de travail16 mA
Fonctionnement continuEnviron 12 heures (charge complète)
MatérielPlastique ABS
Poids net200 g (7.1 onces)
Dimensions120.2 x 64.5 x 38.3 mm
CertificationsJJG693; JJG695: JJG915 and GB3836 series anti-explosion standard, CNEX

7.2 Sampling Pump Specifications (Optional Accessory)

FonctionnalitéDétail
Vol d'exploitationtaget gamme2.2 V-3.2 V CC
Courant de travail<280 mA
Diamètre de la buse2.5 mm
Bruit<75 dB
Dimensions100.8 x 62.3 x 50 mm
Max Sample DistanceEnviron. 50 pieds
Air Flow VelocityApprox. 0.5 cubic inches per hour

8. Garantie et assistance

8.1 Informations sur la garantie

Your SMART SENSOR AS8906 Handheld NO2 Gas Leak Detector comes with a warranty. Please refer to the included Warranty Card in your package for specific terms and conditions, including warranty period and coverage details.

8.2 Assistance clientèle

For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact SMART SENSOR customer support. Contact information can typically be found on the product packaging, the warranty card, or the official SMART SENSOR website.

Documents connexes - AS8906

Préview SMART SENSOR AS8800C Combustible Gas Detector Instruction Manual
User manual for the SMART SENSOR AS8800C Combustible Gas Detector. Provides detailed information on technical specifications, display features, operation instructions, safety precautions, and common gas properties for detecting flammable gases.
Préview Manuel d'utilisation du détecteur d'oxygène SMART SENSOR AR8100
Manuel d'utilisation du détecteur d'oxygène portable SMART SENSOR AR8100. Apprenez à l'utiliser, à le calibrer et à interpréter les mesures pour une mesure précise du taux d'oxygène dans différents environnements.
Préview Détecteurs et moniteurs de gaz à capteur intelligent - Catalogue de produits
Découvrez la gamme complète de détecteurs et de moniteurs de gaz Smart Sensor, comprenant des détecteurs multigaz, monogaz et spécialisés pour diverses applications industrielles et de sécurité. View spécifications, caractéristiques et détails d'emballage.
Préview DceL NO2 Nitrogen Dioxide Sensor | Technical Data Sheet | DD Scientific
Detailed technical data sheet for the DD Scientific DceL NO2 Nitrogen Dioxide (NO2) sensor, covering performance characteristics, environmental details, cross-sensitivity, intrinsic safety data, and product specifications.
Préview Dwyer Series GSTC Carbon Monoxide/Nitrogen Dioxide Gas Transmitter: Specifications & Installation Guide
Detailed specifications, installation, and operating instructions for the Dwyer Series GSTC Carbon Monoxide and Nitrogen Dioxide Gas Transmitter. Covers BACnet and Modbus communication protocols, wiring, and maintenance for industrial environments.
Préview Détecteur de fuites de gaz combustibles Mastercool IntellaSense III, modèle 55975 - Instructions d'utilisation
Instructions d'utilisation complètes et spécifications du détecteur de fuites de gaz combustible Mastercool IntellaSense III (modèle 55975), détaillant ses caractéristiques, ses fonctions, son entretien et ses précautions de sécurité.