1. Introduction

Welcome to the instruction manual for your Sygonix SY-RSL-T3 Wireless Wall Switch. This manual provides essential information for the safe and efficient use of your device. Please read it thoroughly before installation and operation, and keep it for future reference.

2. Consignes de sécurité

Respectez toujours les consignes de sécurité suivantes afin d'éviter les blessures ou d'endommager l'appareil :

  • N'ouvrez pas l'appareil casing. Il n'y a aucune pièce réparable par l'utilisateur à l'intérieur.
  • Tenez l'appareil à l'écart de l'humidité, de l'eau et des températures extrêmes.
  • Use only the specified battery type (12V, not included) and ensure correct polarity during installation.
  • Mettez au rebut les piles usagées conformément à la réglementation locale. Ne jetez pas les piles avec les ordures ménagères.
  • This device is designed for indoor use. If used outdoors, ensure it is protected from direct weather exposure.
  • Conserver les matériaux d’emballage hors de portée des enfants.

3. Produit terminéview

3.1. Composants

The Sygonix SY-RSL-T3 Wireless Wall Switch consists of the following main components:

  • Wireless Wall Switch Unit (1 piece)
  • Mounting Hardware (screws, if included with purchase)
Sygonix SY-RSL-T3 Wireless Wall Switch, front view with two push-buttons labeled 'I' and 'O'.

This image shows the front of the Sygonix SY-RSL-T3 wireless wall switch. It is white with two large push-buttons. The left button is marked with an 'I' (for ON) and a circle (for OFF), and the right button is similarly marked. The switch has a slightly curved, modern design.

3.2. Caractéristiques

  • Surface-mounted RSL wall switch
  • Maximum wireless range: 70 meters (in open field)
  • Push-button style operation (ON-OFF mode)
  • Requires 12V battery (not included)
  • Matériau : plastique

4. Configuration et installation

4.1. Déballage

Carefully remove all components from the packaging. Ensure all parts are present and undamaged. Retain the packaging for future transport or storage.

4.2. Installation de la batterie

The device requires a 12V battery (not included). To install the battery:

  1. Locate the battery compartment on the back of the switch.
  2. Ouvrez le couvercle du compartiment à piles.
  3. Insert the 12V battery, ensuring correct polarity (+ and - terminals match the markings).
  4. Fermez soigneusement le couvercle du compartiment à piles.

4.3. Mounting the Wall Switch

The SY-RSL-T3 is a surface-mounted switch. Choose a suitable, flat location for installation, free from excessive moisture or heat. Use appropriate screws or adhesive (not specified if included) to secure the switch to the wall. Ensure the mounting surface is clean and dry before installation.

Sygonix SY-RSL-T3 Wireless Wall Switch, angled view.

Un angle view of the white Sygonix SY-RSL-T3 wireless wall switch, highlighting its two push-buttons and sleek profile.

Sygonix SY-RSL-T3 Wireless Wall Switch, side view.

Un côté view of the Sygonix SY-RSL-T3 wireless wall switch, showing its depth and how it would sit on a surface.

5. Mode d'emploi

5.1. Pairing with an RSL Receiver

To operate the switch, it must first be paired with a compatible Sygonix RSL receiver (sold separately). The SY-RSL-T3 uses the RSL wireless protocol.

  1. Refer to your RSL receiver's instruction manual for specific pairing instructions.
  2. Typically, you will need to put the RSL receiver into a pairing or learning mode.
  3. Within the specified time frame (usually a few seconds), press one of the buttons (e.g., 'I' or 'O') on the SY-RSL-T3 wall switch.
  4. The receiver should indicate successful pairing (e.g., by flashing an LED or clicking).
  5. Repeat the process if you wish to pair the other button to a different receiver or channel, if supported by your receiver.

5.2. Fonctionnement de base

Once successfully paired with an RSL receiver:

  • Press the button marked with 'I' to send an ON signal to the paired receiver.
  • Press the button marked with 'O' to send an OFF signal to the paired receiver.

The switch operates in a simple ON-OFF mode, controlling the connected device via the RSL receiver.

6. Entretien

6.1. Nettoyage

Clean the surface of the switch with a soft, dry, lint-free cloth. Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the plastic surface.

6.2. Remplacement de la batterie

When the switch's wireless range decreases significantly, or it stops responding to button presses, the battery may need replacement. Follow the steps in section 4.2 (Battery Installation) to replace the 12V battery.

7. Dépannage

ProblèmeCause possibleSolution
L'appareil ne répond pas aux pressions sur les boutons.Batterie morte ou faible.
Not paired with receiver.
Receiver is out of range or not powered.
Remplacez la pile 12V.
Perform the pairing procedure (see section 5.1).
Ensure the RSL receiver is powered and within the 70m range.
Portée sans fil réduite.Batterie faible.
Obstructions between switch and receiver.
Remplacez la pile 12V.
Minimize physical obstructions (e.g., thick walls, metal objects) between the switch and the receiver.

8. Spécifications

FonctionnalitéDétail
FabricantSygonix
Numéro de modèleSY-3523488
Dimensions du produit (L x l x H)1.9 x 8 x 8 cm (19 x 80 x 80 mm)
Poids100 grammes
MatérielPlastique
Source d'énergieAlimenté par batterie
Batterie requiseYes (12 Volts, not included)
Changer de styleBouton
Mode de fonctionnementALLUMÉ ÉTEINT
Évaluation actuelle1 A
Protocole sans filRSL
Max. Range (open field)70 mètres
Quantité par colis1 unité
Disponibilité des pièces détachées (UE)1 an

9. Garantie et assistance

Sygonix provides a 1-year warranty for spare parts availability within the EU. For further support, technical assistance, or warranty claims, please contact your retailer or Sygonix customer service. Please have your model number (SY-3523488) and ASIN (B07NLBNPTF) ready when contacting support.

Fabricant: Sygonix
Numéro de modèle : SY-3523488
ASIN: B07NLBNPTF

Documents connexes - SY-3523488

Préview Prise Wi-Fi intelligente Sygonix SY-RS-200 : Instructions d’utilisation et informations de sécurité
Instructions d'utilisation complètes et consignes de sécurité pour la prise Wi-Fi intelligente Sygonix SY-RS-200, détaillant l'installation, l'utilisation et les spécifications techniques.
Préview Sygonix Funk-Wetterstation Bedienungsanleitung
Diese Bedienungsanleitung bietet detaillierte Informationen zur Sygonix Funk-Wetterstation (Bestellnummer 2754782). Erfahren Sie mehr über Funktionen, Installation, Bedienung, Sicherheitshinweise und technische Daten.
Préview Istruzioni di Sicurezza e Manuale Utente: Tastierino Sygonix MIFARE RFID IP66
Manuale completo per il tastierino Sygonix MIFARE RFID (13,56 MHz, IP66). Include istruzioni di sicurezza, installazione, uso e manutenzione per il controllo accessi e sistemi di allarme.
Préview Dismantling Instructions for Sygonix LED Tri-proof Tube Light (Item 2525879)
Step-by-step guide for safely dismantling the Sygonix LED Tri-proof tube light (Item 2525879), including essential recommendations and detailed instructions for component removal and tube replacement.
Préview Instrukcja obsługi zamka kodowego RFID/IP66 Sygonix
Instrukcja obsługi dla zamka kodowego RFID/IP66 Sygonix, zawierająca informacje o montażu, podłączaniu, programowaniu i bezpieczeństwie.
Préview Instructions de démontage du tube LED Sygonix
Guide étape par étape pour démonter en toute sécurité un tube lumineux LED Sygonix, numéro d'article 2525882. Comprend des recommandations et des instructions détaillées.