KING TKIT-2B

King Electric TKIT-2B Double Pole Built-in Thermostat Kit

Manuel d'instructions

1. Plus deview

This manual provides instructions for the installation, operation, and maintenance of the King Electric TKIT-2B Double Pole Built-in Thermostat Kit. This kit is designed for use with specific King Electric electric heater models, including PX, KT, KTW, PAW, W, and WHF. It functions as a snap-action, single-pole or double-pole integrated thermostat.

2. Informations importantes sur la sécurité

AVERTISSEMENT : Risque de choc électrique. Coupez l’alimentation avant toute installation ou intervention.

3. Contenu du colis

Carefully unpack the kit and ensure all items are present and undamaged. If any parts are missing or damaged, contact your retailer immediately.

4. Instructions d'installation

This thermostat kit is designed for field installation or replacement in compatible King Electric heaters. Refer to your specific heater's manual for detailed access instructions.

  1. Débrancher l'alimentation : Ensure the main power supply to the heater is turned OFF at the circuit breaker before proceeding. Verify with a voltage testeur.
  2. Compartiment de chauffage accessible : Remove the front cover or access panel of your King Electric heater to expose the wiring compartment where the thermostat will be installed. (Refer to your heater's specific manual for cover removal.)
  3. Identifier le câblage : Locate the designated thermostat wiring connections within the heater. The TKIT-2B is a double-pole thermostat, meaning it interrupts both hot legs of a 240V circuit.
  4. Monter le thermostat : Secure the TKIT-2B thermostat module into the designated mounting location within the heater's control compartment using the provided hardware. Ensure it is firmly seated.
  5. Connexions filaires :
    • Connect the incoming power wires to the appropriate terminals on the thermostat.
    • Connect the heater element wires to the corresponding output terminals on the thermostat.
    • Ensure all connections are tight and secure. Follow the wiring diagram provided with your heater or the thermostat kit if available.
  6. Remplacer le couvercle : Carefully replace the heater's front cover or access panel, ensuring no wires are pinched.
  7. Restaurer l'alimentation : Remettez l'alimentation principale en marche au niveau du disjoncteur.
  8. Opération de test : Proceed to the "Operation" section to test the thermostat's functionality.

Note: For single-pole applications, consult a qualified electrician or the heater's specific wiring diagram for proper connection.

5. Mode d'emploi

The TKIT-2B is a mechanical, non-programmable thermostat designed for simple temperature control.

  1. Réglage de la température : Rotate the thermostat knob (if exposed on the heater's exterior) clockwise to increase the desired temperature setting, and counter-clockwise to decrease it.
  2. Cycle de chauffage : When the ambient room temperature falls below the set temperature, the thermostat will activate the heater. When the room temperature reaches the set point, the thermostat will turn off the heater.
  3. Position ARRÊT : Some heater models may have an "OFF" position integrated with the thermostat knob. Turning the knob fully counter-clockwise will typically turn off the heater.

Note: Allow some time for the room temperature to stabilize after making adjustments.

6. Entretien

The King Electric TKIT-2B thermostat requires minimal maintenance.

7. Dépannage

If your heater is not operating as expected after installing the TKIT-2B thermostat, refer to the following common issues and solutions:

ProblèmeCause possibleSolution
Le radiateur ne s'allume pas.Pas d'alimentation au chauffage.
Thermostat réglé trop bas.
Connexion de câblage desserrée.
Vérifiez le disjoncteur.
Augmentez le réglage du thermostat.
(WARNING: Disconnect power) Vérifiez les connexions de câblage.
Le chauffage fonctionne en continu.Thermostat réglé trop haut.
Dysfonctionnement du thermostat.
Diminuez le réglage du thermostat.
If problem persists, contact a qualified electrician for inspection or replacement.
Régulation imprécise de la température.Sonde du thermostat obstruée.
Drafts near heater/thermostat.
Ensure nothing is blocking the thermostat's sensing area.
Seal drafts if possible.

If troubleshooting steps do not resolve the issue, contact King Electric customer support or a qualified electrician.

8. Spécifications

9. Garantie et assistance

For warranty information, please refer to the documentation included with your King Electric heater or visit the official King Electric webConsultez le site. Conservez votre reçu d'achat comme preuve d'achat.

For technical support or assistance, please contact King Electric customer service. Contact details can typically be found on the manufacturer's website or in your heater's manual.

King Électrique Website: www.king-electric.com

Documents connexes - TKIT-2B

Préview Guide d'installation et d'entretien du chauffage King série LPW-ECO
Guide complet pour l'installation, l'utilisation et l'entretien des radiateurs électroniques de la série King LPW-ECO, comprenant les consignes de sécurité, les schémas de câblage, la configuration du capteur à distance et le dépannage.
Préview Kit thermostat RF sans fil 24 V King KRF-HEAT-KIT pour le contrôle du chauffage électrique
Guide complet du King KRF-HEAT-KIT, un système de thermostat sans fil RF 24 V conçu pour les tensions de lignetagCommande de chauffage électrique. Elle comprend le thermostat programmable KRFTP-B et le relais KRFLR-120/240V, avec des spécifications détaillées, des informations de commande et des accessoires optionnels pour un contrôle amélioré et des économies d'énergie.
Préview Guide d'installation du chauffage de corniche King série KCV
Instructions d'installation officielles pour le chauffage de corniche King série KCV (modèle KCV1202), détaillant les précautions de sécurité, la configuration électrique, le montage, le câblage et l'entretien.
Préview Chauffage d'atelier portable King PSH2440TB : Manuel d'installation, d'utilisation et de sécurité
Ce manuel complet fournit toutes les informations essentielles concernant le chauffage d'atelier portable King PSH2440TB, notamment l'installation, les consignes de sécurité, le mode d'emploi, les conseils d'entretien et le dépannage. Conçu pour une utilisation en garage ou en atelier, il offre une puissance de 3 750 W et fonctionne sous 240 V.
Préview Radiateur électrique King série W : Guide d'installation, d'utilisation et d'entretien
Guide complet pour les radiateurs électriques de la série King W, couvrant l'installation, le câblage, le fonctionnement, les avertissements de sécurité, le dépannage, la maintenance et les informations de garantie.
Préview Chauffage King LPW ECO2S PRO : Manuel d’installation, d’entretien et d’utilisation
Guide complet pour le King LPW ECO2S PRO 2-S programmable sur 7 jourstagChauffage électronique avec télécommande de température. Instructions d'installation, de câblage et d'alimentation incluses.tagInformations sur la sélection, l'installation, le fonctionnement, la maintenance, le dépannage et la garantie.