Introduction
The SEBSON GS536GC photoelectric smoke detector is designed to provide early warning of dangerous smoke development. This device is certified according to DIN EN 14604 standards, ensuring reliable performance. Upon detecting smoke, the alarm emits a loud sound to alert occupants. The detector also features a self-test function and a low battery warning system for continuous safety monitoring.
Contenu du colis
Vérifiez que tous les éléments énumérés ci-dessous sont présents dans votre colis :
- 6 x SEBSON GS536GC Smoke Detectors
- 6 x 9V DC Block Batteries (Alkaline)
- 12 x vis de montage
Consignes de sécurité
Please read and understand all safety instructions before installation and use. Failure to do so may result in improper operation and potential hazards.
- Ne pas peindre : Ne jamais peindre le détecteur de fumée. La peinture peut obstruer les chambres de détection et empêcher l'appareil de fonctionner correctement.
- Tests réguliers : Test the smoke detector weekly to ensure it is functioning properly.
- Remplacement de la batterie : Replace the battery immediately when the low battery warning sounds. Although the included battery has a 5-year life, individual battery performance may vary.
- Placement: Installez des détecteurs de fumée dans toutes les chambres et à tous les étages de votre maison, y compris au sous-sol.
- Entretien: Keep the detector clean and free from dust.
- Élimination: Dispose of used batteries and the smoke detector according to local regulations.
Configuration et installation
Proper installation is crucial for the effective operation of your smoke detector.
1. Choix d'un emplacement d'installation
Install smoke detectors on the ceiling in the center of the room, or at least 50 cm (20 inches) from any wall. Avoid installing in:
- Cuisines, salles de bains ou garages où les fumées de cuisson, la vapeur ou les gaz d'échappement peuvent provoquer de fausses alarmes.
- Near ventilation openings, air conditioners, or fans, as air currents can prevent smoke from reaching the detector.
- Areas with high humidity or extreme temperatures (outside 0°C to +37°C).

Image: A SEBSON GS536GC smoke detector mounted on a white ceiling, demonstrating a typical installation location.
2. Installation de la batterie
- Remove the mounting bracket from the smoke detector by twisting it counter-clockwise.
- Insert the provided 9V DC block battery into the battery compartment, ensuring correct polarity (+/-).
- The detector will emit a short beep to indicate successful battery installation.
3. Montage du détecteur
You can mount the detector using the included screws or an appropriate adhesive (not included).
- Montage à vis :
- Mark two drill holes on the ceiling using the mounting bracket as a template.
- Percez les trous et insérez des chevilles si nécessaire.
- Fixez le support de montage au plafond à l'aide des vis fournies.
- Align the smoke detector with the mounting bracket and twist clockwise until it locks securely in place.
- Adhesive Mounting (Optional, not recommended for all surfaces):
- Ensure the ceiling surface is clean, dry, and smooth.
- Apply a suitable adhesive (e.g., double-sided adhesive pad, not included) to the back of the mounting bracket.
- Press the bracket firmly onto the desired ceiling location for at least 30 seconds.
- Align the smoke detector with the mounting bracket and twist clockwise until it locks securely in place.

Image: Technical drawing illustrating the dimensions of the smoke detector (90mm diameter, 31mm height).

Image: Another technical drawing providing an isometric view of the smoke detector with its dimensions.
Mode d'emploi
Fonctionnement normal
Once installed with a fresh battery, the smoke detector will enter normal operating mode. A short flash of the LED indicator every 32 seconds confirms that the unit is powered on and performing its self-test function.

Image : Avant view of the smoke detector, highlighting the test button and LED indicator area.
Test du détecteur
To manually test the smoke detector, press and hold the central test button for approximately 5 seconds. The alarm will sound loudly, and the LED will flash rapidly. Release the button to stop the alarm. This test verifies the battery, alarm, and sensing circuitry are working correctly.
Signal d'alarme
When smoke is detected, the alarm will emit a loud, continuous sound (≥ 85 dB at 3 meters) and the LED will flash rapidly. In case of an alarm, evacuate the premises immediately and contact emergency services.
Avertissement de batterie faible
When the battery is low, the detector will emit a short chirp approximately every 30-40 seconds, accompanied by a brief LED flash. This indicates that the battery needs to be replaced immediately.
Entretien
Un entretien régulier garantit la fiabilité continue de votre détecteur de fumée.
- Tests hebdomadaires : Press the test button weekly to confirm the alarm is functioning.
- Nettoyage mensuel : Gently vacuum the exterior of the smoke detector with a soft brush attachment to remove dust and cobwebs. Do not use cleaning agents or solvents.
- Remplacement de la batterie : Replace the 9V alkaline battery when the low battery warning sounds. Although the battery has a 5-year life, it is replaceable. Always use a fresh, high-quality 9V alkaline battery.

Image : Côté view of the smoke detector, illustrating the air intake vents that should be kept clear of dust.
Dépannage
| Problème | Cause possible | Solution |
|---|---|---|
| Le détecteur émet un signal sonore toutes les 30 à 40 secondes. | Batterie faible. | Remplacez immédiatement la pile alcaline 9V. |
| L'alarme retentit sans fumée visible. | Dust or insects in the sensing chamber, high humidity, or proximity to cooking fumes/steam. | Clean the detector with a vacuum cleaner. Relocate the detector if it's too close to sources of steam or fumes. |
| Le détecteur ne sonne pas pendant le test. | Dead or improperly installed battery, or faulty unit. | Check battery installation and replace if necessary. If the problem persists, the unit may be faulty and needs replacement. |
| LED does not flash every 32 seconds. | Pas d'alimentation ou appareil défectueux. | Check battery installation and replace if necessary. Ensure the battery is fresh. If still no flash, replace the unit. |
Caractéristiques
| Fonctionnalité | Détail |
|---|---|
| Modèle | GS536GC |
| Type de capteur | Photoélectrique |
| Certification | DIN EN 14604 |
| Source d'énergie | 9V DC Block Battery (Alkaline) |
| Autonomie de la batterie | Jusqu'à 5 ans (remplaçable) |
| Volume de l'alarme | ≥ 85 dB (A) à 3 mètres |
| Sensibilité à la fumée | 0.085 à 0.1377 dB / m |
| Température de fonctionnement | 0°C à +37°C |
| Dimensions (Diamètre x Hauteur) | 90 mm x 31 mm |
| Couleur | Blanc |
| Poids unitaire | Environ 160 g |
Garantie et assistance
Pour obtenir des informations sur la garantie ou une assistance technique, veuillez vous référer au site officiel du fabricant. webConsultez le site ou contactez directement leur service client. Conservez votre reçu d'achat comme preuve d'achat.
Fabricant: SEBSON