Pedrollo JSWm/2CX

PEDROLLO JSWm/2CX Self-Priming Water Pump User Manual

Model: JSWm/2CX | Brand: Pedrollo

Introduction

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your PEDROLLO JSWm/2CX self-priming water pump. Please read these instructions carefully before installation or use and retain them for future reference.

PEDROLLO JSWm/2CX Self-Priming Water Pump

Figure 1 : PEDROLLO JSWm/2CX Self-Priming Water Pump. This image shows the blue-colored pump unit with its motor housing and pump body, designed for efficient water transfer.

Consignes de sécurité

Respectez toujours les consignes de sécurité suivantes afin d'éviter les blessures ou d'endommager la pompe :

  • Ensure the pump is installed by a qualified professional.
  • Coupez l'alimentation électrique avant toute opération de maintenance ou d'entretien.
  • Ne pas utiliser la pompe avec des liquides inflammables ou corrosifs.
  • Protéger la pompe des températures glaciales.
  • Assurez-vous d'une mise à la terre correcte de la connexion électrique.

Produit terminéview

The PEDROLLO JSWm/2CX is a self-priming centrifugal pump designed for reliable water transfer. It is suitable for pumping clean water and liquids that are not chemically aggressive to the pump's components. Its self-priming capability allows it to draw water even when air is present in the suction line, making it ideal for domestic water supply, small to medium autoclave tank systems, and garden irrigation.

Caractéristiques principales :

  • Self-priming design for efficient operation.
  • Suitable for clean water and non-aggressive liquids.
  • Robust construction with stainless steel components.
  • Designed for continuous duty in domestic and garden applications.

Configuration et installation

Proper installation is crucial for the pump's performance and longevity. Consult a qualified technician for installation.

  1. Emplacement: Install the pump in a dry, well-ventilated area, protected from direct sunlight and freezing temperatures. Ensure adequate space for maintenance.
  2. Montage: Securely fasten the pump to a stable, level surface using appropriate bolts to minimize vibration.
  3. Tuyauterie:
    • Use pipes of adequate diameter to minimize friction losses.
    • Ensure all connections are airtight, especially on the suction side, to prevent air ingress.
    • Install a foot valve with a strainer at the end of the suction pipe to prevent debris from entering the pump and to maintain prime.
    • Install a gate valve on both the suction and discharge sides for isolation during maintenance.
  4. Connexion électrique :
    • Connect the pump to a suitable power supply (220-230V, 50Hz) as indicated on the motor's data plate.
    • Ensure the electrical circuit is protected by a residual current device (RCD) and an appropriately rated circuit breaker.
    • Verify proper grounding according to local electrical codes.
  5. Amorçage: Avant la première mise en marche, remplissez complètement le réservoir de la pompe.asing and the suction line with clean water through the priming port. This is essential for self-priming pumps to initiate operation.

Mode d'emploi

  1. Démarrage initial: After installation and priming, open the discharge valve fully. Switch on the power supply. The pump should start and begin to draw water.
  2. Fonctionnement continu : Monitor the pump for unusual noises or vibrations. Ensure the pump is not running dry, as this can cause severe damage.
  3. Fermer: To stop the pump, switch off the power supply. If the pump is part of an automatic system (e.g., with a pressure switch), it will start and stop automatically based on demand.
  4. Limites de température :
    • Liquid temperature: up to +40 °C.
    • Ambient temperature: -10 °C to +40 °C.

Entretien

Un entretien régulier garantit des performances optimales et prolonge la durée de vie de la pompe. Coupez toujours l'alimentation électrique avant toute intervention.

  • Contrôles réguliers : Inspect the pump and piping for leaks, corrosion, or damage.
  • Nettoyage de la passoire : Periodically clean the foot valve strainer to prevent blockages and maintain flow.
  • Hivérisation: In areas prone to freezing, drain the pump completely and store it in a warm, dry place, or insulate it adequately to prevent damage from ice expansion.
  • Inspection du moteur : Ensure the motor's cooling fins are free from dust and debris to prevent overheating.

Dépannage

ProblèmeCause possibleSolution
La pompe ne démarre pasNo power supply; Motor overload; Seized impeller.Check power connection and circuit breaker; Reset thermal overload; Contact service technician.
La pompe fonctionne mais l'eau n'est pas distribuée.Pump not primed; Air leak in suction line; Foot valve clogged; Suction lift too high.Re-prime the pump; Check all suction connections for leaks; Clean foot valve strainer; Reduce suction lift if possible.
Débit ou pression réduitsPartial blockage in piping; Worn impeller; Air in system.Inspect and clear piping; Contact service technician for impeller replacement; Bleed air from system.
Bruit ou vibration excessifCavitation (air in water); Loose mounting; Bearing wear.Check for air leaks and ensure proper priming; Tighten mounting bolts; Contact service technician.

Caractéristiques

ParamètreValeur
ModèleJSWm/2CX
MarquePedrollo
Puissance (CV)1 CV
Voltage / Fréquence220-230V / 50Hz
Débit max.70 litres par minute
Plage de température du liquideJusqu'à +40 °C
Plage de température ambiante-10 °C à +40 °C
MatérielStainless Steel (pump body components)
ASINB07HMZ2DKQ
Code international des articles08052230012515

Note: The specification for "Power: 220 Watts" found in some product listings may refer to a specific component or a different metric. The pump's performance is rated at 1 HP.

Garantie et assistance

For warranty information, technical support, or spare parts, please contact your authorized Pedrollo dealer or visit the official Pedrollo webConsultez le site. Conservez votre reçu d'achat comme preuve d'achat.

Fabricant: PEDROLLO

Documents connexes - JSWm/2CX

Préview PRESET Electronic Pressure Switch by Pedrollo - Installation and Technical Data
Detailed information on the Pedrollo PRESET electronic pressure switch, including technical specifications, performance range, application limits, installation guide, and dimensions. Ideal for domestic water supply and pressure boosting.
Préview Dispositif de protection électronique Pedrollo EP - Manuel d'utilisation et fiche technique
Guide complet du dispositif de protection électronique Pedrollo EP, détaillant ses caractéristiques, ses spécifications techniques, son installation et son fonctionnement. Protège les pompes contre le fonctionnement à sec, les surintensités et les surtensions.tage, et sous-voltage. Convient à un usage domestique.
Préview Pedrollo QEM/QET Control Boxes for 4" Borehole Pumps Operating Instructions
Official operating instructions and technical specifications for Pedrollo QEM and QET control boxes designed for 4-inch borehole pumps. Includes safety warnings, installation guidelines, operational commands, and warranty information.
Préview Manuale di Installazione e Uso Pedrollo Serie 2÷5CP-1, 2÷5CR, FCR, MK, HT, HT-PRO
Guida completa per l'installazione, l'uso e la manutenzione sicura delle elettropompe Pedrollo serie 2÷5CP-1, 2÷5CR, FCR, MK, HT, HT-PRO. Informazioni dettagliate, avvertenze di sicurezza e dati tecnici.
Préview Panneaux électriques électroniques Pedrollo E1-E2 pour pompes
Guide complet des panneaux de commande électroniques Pedrollo E1 et E2, conçus pour la gestion de systèmes de pompage simples ou doubles dans les environnements résidentiels, commerciaux et industriels. Ils offrent notamment des modes de fonctionnement sélectionnables, une protection contre la marche à sec et des interfaces utilisateur intuitives pour une utilisation optimale des pompes.
Préview Pedrollo STEADYPRES : Variateur électronique de fréquence pour pompe
Manuel complet pour le Pedrollo STEADYPRES, un onduleur pour le contrôle de l'électropompe. Offre isstruzioni dettagReliez votre installation, votre configuration, votre fonctionnement, votre gestion de l'alarme, votre garantie de résolution et vos données techniques pour optimiser la pression et protéger la pompe.