SenseAir 00-0-0016

User Manual: CO2 + Temperature + Humidity Meter

Model: 00-0-0016 | Brand: SenseAir

1. Introduction

The SenseAir pSENSE RH is a portable instrument designed for accurate measurement of indoor air quality parameters. It precisely measures carbon dioxide (CO2) concentration, ambient temperature, and relative humidity. This device is equipped with an integrated alarm buzzer and advanced computational capabilities to display maximum (MAX), minimum (MIN), average, time-weighted average (TWA), and short-term exposure limit (STEL) values, making it an essential tool for environmental monitoring and assessment.

2. caractéristiques du produit

  • Measures CO2 concentration in ranges of 0-5000ppm (with an accuracy of ±30ppm ±5%rdg) and up to 9999ppm.
  • Calculates and displays 8-hour Time-Weighted Average (TWA) and 15-minute Short-Term Exposure Limit (STEL) values.
  • Provides MAX, MIN, and Average value display functions.
  • Equipped with RS232 data output for connectivity and data logging.
  • Includes an integrated alarm buzzer for high CO2 levels.
  • Comes with a dedicated hard case for protection and portability.

3. Appareil terminéview

SenseAir pSENSE RH CO2, Temperature, and Humidity Meter

Figure 1 : Devant view of the SenseAir pSENSE RH meter. The device features a digital display showing CO2 concentration (in ppm), air temperature (in °C), and relative humidity (in %). Below the display are six control buttons: SET, MODE, CAL/Esc, DP/WBT, HOLD, and M/AV. The top of the device houses the sensor probe.

Composants clés :

  • Sonde de capteur : Located at the top, for CO2, temperature, and humidity detection.
  • Écran LCD : Shows real-time readings for CO2 (ppm), Air Temperature (°C), and Relative Humidity (%).
  • Boutons de contrôle :
    • SET: Used for entering setup menus and confirming selections.
    • MODE: Toggles between different display modes (e.g., current, MAX, MIN, AVG, TWA, STEL).
    • CAL/Esc: Initiates calibration or exits a menu/function.
    • DP/WBT: Likely for Dew Point or Wet Bulb Temperature display (specific function may vary by model).
    • TENIR: Fige la lecture actuelle affichée.
    • M/AV: Likely for memory functions or switching between manual and automatic averaging.
  • Port RS232 : Pour la communication de données avec des appareils externes.

4. Installation

  1. Déballage : Carefully remove the pSENSE RH meter and its accessories from the packaging. Inspect for any signs of damage.
  2. Alimentation: Insert the required batteries into the designated compartment, observing correct polarity. Alternatively, connect the device to an appropriate power adapter if available.
  3. Placement initial : For accurate readings, place the device in the environment you wish to monitor, ensuring the sensor probe is exposed to the ambient air and not obstructed. Avoid direct sunlight or strong drafts.
  4. Mise sous tension : Press the power button (if present, or the SET button for a moment) to turn on the device. The display should illuminate and show initial readings.

5. Mode d'emploi

5.1 Mesure de base

Once powered on, the pSENSE RH will automatically begin measuring and displaying real-time CO2 concentration, temperature, and relative humidity on the LCD screen.

5.2 Sélection du mode

Appuyez sur le MODE button to cycle through different display modes. These typically include:

  • Lectures actuelles
  • Maximum (MAX) recorded values
  • Minimum (MIN) recorded values
  • Average (AVG) values
  • 8-hour Time-Weighted Average (TWA)
  • 15-minute Short-Term Exposure Limit (STEL)

5.3 Lectures de maintien

Appuyez sur le PRISE button to freeze the current readings on the display. Press it again to release and resume real-time measurements.

5.4 Data Output (RS232)

Connect the device to a computer or data logger via the RS232 port using a compatible cable. Refer to the specific software or communication protocol documentation for detailed instructions on data retrieval and analysis.

6. Entretien

6.1 Nettoyage

Wipe the device exterior with a soft, dry cloth. Do not use abrasive cleaners or solvents. Keep the sensor probe free from dust and debris.

6.2 Étalonnage

Regular calibration ensures the accuracy of your pSENSE RH meter. To initiate calibration, press the CAL/Échap button. Follow the on-screen prompts or refer to the detailed calibration procedure in the full technical manual (if applicable) for specific instructions, which may involve exposure to a known CO2 concentration.

6.3 Stockage

When not in use, store the device in its dedicated hard case in a cool, dry place, away from extreme temperatures and humidity.

7. Dépannage

7.1 Sans affichage/alimentation

  • Vérifiez l'installation des piles et assurez-vous qu'elles ne sont pas déchargées.
  • Verify power adapter connection if using external power.

7.2 Lectures inexactes

  • Ensure the sensor probe is clean and unobstructed.
  • Perform a calibration procedure as described in the Maintenance section.
  • Avoid placing the device near heat sources, vents, or in direct sunlight, which can affect temperature and humidity readings.

7.3 Alarm Buzzer Issues

  • Check the alarm threshold settings in the device's menu (refer to the full manual for navigation).
  • Ensure the CO2 level is above the set threshold if the alarm is expected to sound.

If issues persist, contact SenseAir customer support for further assistance.

8. Spécifications

ParamètreValeur
FabricantSenseAir
Numéro de pièce00-0-0016
Dimensions du produit (L x l x H)20.9 x 5.8 x 7 cm
Plage de mesure du CO20-5000ppm (±30ppm ±5%rdg), 5001-9999ppm
Valeurs calculées8-hour TWA, 15-minute STEL, MAX, MIN, Average
Sortie de donnéesRS232
Accessoires inclusDedicated hard case

9. Garantie et assistance

For warranty information, technical support, or service inquiries, please contact SenseAir customer service directly. Details regarding warranty periods and service procedures are typically provided with the product documentation or available on the official SenseAir website.

SenseAir Official Website: www.senseair.com (This is a placeholder link as no specific link was provided in the input data)

Documents connexes - 00-0-0016

Préview Manuel d'utilisation du capteur LoRaWAN Senseair ExploraCO2
Manuel d'utilisation du Senseair ExploraCO2, un capteur certifié LoRaWAN, alimenté par batterie, mesurant le CO2, la température et l'humidité en intérieur. Durée de vie : 15 ans. Instructions détaillées d'installation, de configuration et de maintenance incluses.
Préview Manuel d'installation du Senseair tSENSE (Disp) : capteur de CO2, de température et d'humidité
Manuel d'installation officiel du capteur Senseair tSENSE (Disp), détaillant la configuration, le câblage et le montage pour la surveillance du CO2, de la température et de l'humidité relative. Comprend les spécifications techniques et les schémas de connexion.
Préview Senseair Salus User Manual: Test and Diagnostic Tool for Alcohol Screener Products
User manual for the Senseair Salus diagnostic tool, providing instructions for testing and servicing Senseair alcohol screener product handsets. Includes setup, operation, service procedures, and safety information.
Préview Senseair S12 CO2 Low Power Sensor Datasheet and Specifications
Detailed technical specifications, features, and operating conditions for the Senseair S12 CO2 low-power NDIR sensor, designed for next-generation battery, wireless, and HVAC applications.
Préview aSENSE (Disp) RL Installation Manual - Senseair
Installation manual for the Senseair aSENSE (Disp) RL sensor, providing detailed instructions for mounting, dismounting, and electrical connections.
Préview Module de capteur de CO2 SenseAir LP8 : spécifications et guide d'intégration
Guide complet détaillant les spécifications, les descriptions des broches, les caractéristiques électriques et les procédures d'intégration du module de capteur de CO2 SenseAir LP8, conçu pour les applications alimentées par batterie.