1. Introduction
The Extech UV505 is a compact, portable UV-AB light meter designed for measuring ultraviolet radiation from both natural and artificial light sources. This device is suitable for various applications including outdoor UV exposure assessment, medical testing, laboratory research, industrial quality control, educational purposes, electronics, and forensic investigations. It features a backlit display, a cosine-corrected sensor for accurate readings, two selectable measurement ranges, a zero adjustment function, data hold, and an automatic power-off feature to conserve battery life.
2. caractéristiques du produit
- Conception compacte et portable : Easily fits in a hand or pocket for convenient on-the-go monitoring in various environments.
- UVA and UVB Measurement: Dual-sensor technology enables simultaneous and accurate tracking of both UVA and UVB light intensity.
- Data Capture Functions: Includes Peak Hold, Min/Max, and real-time readings to analyze fluctuations and critical UV peaks.
- Écran LCD rétroéclairé : Large, easy-to-read screen with backlight for clear visibility in diverse lighting conditions.
- Construction durable : Rugged design ensures reliable performance in field and laboratory settings.
- Arrêt automatique : Automatically shuts off to preserve battery life during extended use.
- Cosine Corrected Sensor: Provides accurate measurements regardless of the angle of incidence of the UV light.
3. Contenu du colis
Vérifiez que tous les articles sont présents et en bon état :
- Extech UV505 Pocket UV-AB Light Meter
- Two AAA batteries (pre-installed or included separately)
- Pochette de protection
4. Identification des composants

Figure 1 : Face avant view of the Extech UV505 Pocket UV-AB Light Meter, showing the UV sensor, LCD display, and control buttons.

Figure 2: The Extech UV505 meter being held in a hand, demonstrating its portable size and outdoor usability.
The Extech UV505 features a UV sensor at the top, a large LCD display in the center, and several control buttons below the display. The main power button is typically orange and centrally located. Other buttons include ZERO, UNIT, and a backlight button (often indicated by a light bulb icon) and a HOLD button (indicated by 'H'). The battery compartment is located on the rear of the device.
5. Installation
5.1 Installation de la batterie
- Repérez le compartiment à piles à l'arrière de l'appareil.
- Press the release button (if present) and slide open the battery cover.
- Insérez deux piles AAA en respectant la polarité (+ et -).
- Replace the battery cover and ensure it clicks securely into place.
6. Mode d'emploi
6.1 Mise sous/hors tension
- To power on the meter, press the orange power button.
- To power off the meter, press and hold the orange power button until the display turns off. The meter also features an auto power-off function after a period of inactivity.
6.2 Prendre une mesure
- Allumez le compteur.
- Point the UV sensor directly towards the UV light source you wish to measure.
- Read the UV intensity value displayed on the LCD screen.
6.3 Fonction zéro
- To ensure accurate readings, especially in low UV environments, use the ZERO function.
- Cover the UV sensor completely to block all light.
- Press the 'ZERO' button. The display should show '0' or a very small value.
6.4 Sélection d'unité
- Press the 'UNIT' button to cycle through available measurement units, typically µW/cm² (microwatts per square centimeter) and mW/cm² (milliwatts per square centimeter).
6.5 Maintien des données
- Press the 'HOLD' button (often marked 'H') to freeze the current reading on the display.
- Press 'HOLD' again to release the reading and return to live measurement.
Fonction Min/Max 6.6
- While measuring, press the 'MIN/MAX' button (or similar, depending on model) to display the minimum or maximum UV intensity recorded since the function was activated.
- Cycle through Min, Max, and current readings by pressing the button repeatedly.
- To clear Min/Max memory, typically press and hold the 'MIN/MAX' button, or power cycle the device.
6.7 Rétroéclairage
- Press the backlight button (light bulb icon) to illuminate the LCD display for better visibility in low-light conditions.
- Press it again to turn off the backlight.
7. Entretien
7.1 Nettoyage
- Essuyez le compteur casing avec un doux, damp chiffon. N'utilisez pas de nettoyants abrasifs ou de solvants.
- Keep the UV sensor clean and free from dust or debris to ensure accurate readings. Use a soft brush or compressed air if necessary.
7.2 Stockage
- En cas de non-utilisation prolongée, retirez les piles pour éviter les fuites.
- Store the meter in its protective pouch in a cool, dry place, away from direct sunlight and extreme temperatures.
7.3 Remplacement de la batterie
- Lorsque l'indicateur de batterie faible apparaît sur l'écran, remplacez les piles comme décrit dans la section 5.1.
8. Dépannage
- Le compteur ne s'allume pas : Vérifiez l'installation des batteries et assurez-vous qu'elles sont neuves.
- Lectures inexactes : Ensure the sensor is clean and unobstructed. Perform a ZERO calibration. Verify correct unit selection.
- L’affichage est sombre ou scintille : Remplacer les piles.
9. Spécifications
| Spécification | Détail |
|---|---|
| Fabricant | Extech |
| Numéro de pièce | UV505 |
| Poids de l'article | 3.2 onces |
| Dimensions du produit | 1.9 x 1 x 5.2 pouces |
| Numéro de modèle de l'article | UV505 |
| Piles | 2 piles AAA requises (incluses) |
| Type de cellule de batterie | Alcalin |
| Système de mesure | Métrique |
| Composants inclus | Meter, two AAA batteries, and a pouch |
| Date de première disponibilité | 12 juin 2018 |
10. Garantie et assistance
For warranty information or technical support, please refer to the official Extech webConsultez leur site web ou contactez leur service client. Conservez votre reçu d'achat comme preuve d'achat pour toute réclamation au titre de la garantie.