AEMC 6255

AEMC INSTRUMENTS Model 6255 Micro-Ohmmeter User Manual

Precision Resistance Measurement Device

1. Plus deview

The AEMC INSTRUMENTS Model 6255 is a high-precision Micro-Ohmmeter designed for accurate resistance measurements. It is capable of measuring resistance from 0.1 microhm up to 2500 ohms, with a resolution of 0.1 microhm. This device is suitable for a wide range of industrial and scientific applications requiring precise low-resistance measurements.

Key features include an LCD display, an output current range of 0.1A to 10A, and internal data storage for up to 1500 test results. It is powered by an 8.5Ah NiMH battery, ensuring portability and extended operation.

2. Consignes de sécurité

Before operating the AEMC Model 6255, please read and understand all safety instructions. Failure to comply with these instructions may result in electric shock, fire, or damage to the instrument.

3. Composants et caractéristiques du produit

The AEMC Model 6255 Micro-Ohmmeter comes with the following items:

AEMC INSTRUMENTS Model 6255 Micro-Ohmmeter in its yellow protective case, open to show the control panel and LCD display.

Figure 1: AEMC INSTRUMENTS Model 6255 Micro-Ohmmeter.The image displays the AEMC Model 6255 Micro-Ohmmeter housed within its robust yellow protective case, which is shown open. The device itself is yellow and black, featuring a clear LCD display that shows "72.6" and "0.1365 mΩ". To the left of the display are red and black input terminals labeled C1, P1, P2, and C2. Below the display are several control buttons. On the right side, there is a large rotary dial and a yellow START/STOP button. The overall design emphasizes durability and ease of use for industrial applications.

Composants clés :

4. Installation

4.1 Charge initiale

The AEMC Model 6255 is powered by an 8.5Ah NiMH battery. Before first use, or if the battery is low, connect the provided charger to the instrument and a suitable power outlet. Allow sufficient time for the battery to fully charge. The charging indicator on the device will provide status.

4.2 Connexion des cordons de test

The Model 6255 utilizes a 4-wire (Kelvin) measurement method for high accuracy, which requires four connections to the test object. This method minimizes the impact of lead resistance on the measurement.

  1. Ensure the instrument is turned off before connecting leads.
  2. Connect the current leads (C1 and C2) to the outer points of the resistance to be measured.
  3. Connect the potential leads (P1 and P2) to the inner points of the resistance to be measured. These leads measure the voltage drop across the resistance.
  4. Ensure all connections are secure and clean to prevent erroneous readings.

5. Mode d'emploi

5.1 Mise sous/hors tension

Press and hold the power button (if separate, or a specific function on the rotary dial) to turn the instrument on. Repeat the action to turn it off.

5.2 Sélection du mode de mesure

Use the rotary selector switch to choose the desired measurement range or mode. The Model 6255 supports resistance measurements from 0.1 microhm to 2500 ohms.

5.3 Réaliser une mesure

  1. Ensure the test leads are correctly connected to the object under test as described in Section 4.2.
  2. Select the appropriate measurement range using the rotary dial. If unsure, start with a higher range and decrease as needed.
  3. Appuyez sur le DÉMARRER/ARRÊTER button to initiate the measurement. The instrument will apply a test current (0.1A to 10A) and display the resistance value on the LCD.
  4. Wait for the reading to stabilize. The LCD will show the measured resistance with 0.1 microhm resolution.
  5. Appuyez sur le DÉMARRER/ARRÊTER button again to stop the measurement.

5.4 Stockage et récupération des données

The Model 6255 can store up to 1500 test results. Refer to the on-screen menu or specific buttons (e.g., "MEM" or "SAVE") for instructions on saving and recalling measurements. The RS232 interface allows for data transfer to a computer for further analysis.

6. Entretien

6.1 Nettoyage

Nettoyez régulièrement le c de l'instrumentasing et affichage avec un doux, damp cloth. Do not use abrasive cleaners or solvents. Ensure the instrument is turned off and disconnected from any power source before cleaning.

6.2 Entretien de la batterie

To prolong the life of the 8.5Ah NiMH battery:

6.3 Étalonnage

The AEMC Model 6255 is a precision instrument. While the product description states "No Calibration Certificate" is included, periodic calibration by a qualified service center is recommended to ensure continued accuracy and compliance with industry standards. Contact AEMC INSTRUMENTS for calibration services.

7. Dépannage

ProblèmeCause possibleSolution
L'appareil ne s'allume pas.La batterie est déchargée.Connect the charger and allow the battery to charge fully.
Erratic or unstable readings.Poor test lead connections; Interference; Test object issues.Ensure leads are securely connected and clean. Move away from strong electromagnetic fields. Verify the integrity of the test object.
Display shows "OVERLOAD" or "OL".Resistance value exceeds selected range; Open circuit.Select a higher measurement range. Check for open circuits in the test setup.
Impossible d'enregistrer les résultats du test.Mémoire pleine.Transfer stored data to a computer via RS232 and clear instrument memory.

8. Spécifications

ParamètreValeur
Modèle6255
Plage de résistance0.1 microhm to 2500 ohm
Résolution0.1 microhm
Précision+/-0.05 Percent
Courant de sortie0.1A à 10A
AfficherÉcran LCD
Source d'énergie8.5Ah NiMH Battery
Compte2,500
Cote de sécuritéIEC/EN 61010-1 CAT III 50V Pol 2
Stockage des données1500 Résultats des tests
InterfaceRS232
Dimensions du produit1 x 1 x 1 pouces
Poids de l'article0.01 onces
FabricantINSTRUMENTS AEMC

9. Informations sur la garantie

AEMC INSTRUMENTS products are designed and manufactured to the highest quality standards. For specific warranty terms and conditions applicable to your Model 6255 Micro-Ohmmeter, please refer to the warranty card included with your product or visit the official AEMC INSTRUMENTS website. En règle générale, les garanties couvrent les défauts de matériaux et de fabrication dans des conditions normales d'utilisation.

Veuillez conserver votre preuve d'achat pour toute réclamation au titre de la garantie.

10. Assistance clientèle

For technical assistance, service, or repair of your AEMC Model 6255 Micro-Ohmmeter, please contact AEMC INSTRUMENTS customer support.

When contacting support, please have your instrument's model number (6255) and serial number ready.