Instruments Apera AI223

Apera Instruments SX620 pH Pen Tester Kit

Modèle : AI223

Marque : Apera Instruments

Produit terminéview

The Apera Instruments SX620 pH Pen Tester is engineered for precise and reliable pH measurements in a compact, user-friendly design. It is an economical solution for a wide range of liquid testing applications, including hydroponics, aquaculture, water treatment, and beverage production. Its slim 8mm probe is replaceable and ideal for use with test tubes.

Caractéristiques principales

  • 0.01 pH accuracy for precise readings.
  • Automatic 3-point calibration for enhanced accuracy.
  • Automatic Temperature Compensation (ATC) from 0-60°C.
  • Slim, replaceable probe suitable for test tubes.
  • Intelligent functions: switchable temperature units (°F/°C), automatic power-off, low battery alarm, and pH probe invalidation reminder.
  • IP57 waterproof and dustproof rating, allowing it to float if dropped in water.

Contenu du colis

  • 1 x Apera Instruments SX620 pH Pen Tester
  • 1 x SX620 pH Pen Kit (includes tester)
  • 3 x Premixed Calibration Solutions (pH 4.00, pH 7.00, pH 10.01)
  • 1 x 3M KCL Storage Solution
  • 2 x CR2032 Lithium Batteries (pre-installed or included)
  • 1 x étui de transport portable
  • 1 x cordon
Apera Instruments SX620 pH Pen Tester Kit contents in blue carrying case

The complete kit, including the SX620 pH pen tester, calibration solutions, storage solution, and a carrying case.

Installation

Installation de la batterie

The SX620 pH Pen Tester uses two CR2032 lithium batteries. These are typically pre-installed or included in the kit. To install or replace batteries, locate the battery compartment, usually at the top of the meter, and follow the markings for correct polarity.

Initial Probe Preparation

Before first use, or after prolonged storage, remove the protective cap from the probe. Rinse the probe with distilled water. If the probe has dried out, soak it in 3M KCL storage solution for at least 30 minutes to rehydrate the electrode. Ensure the probe is fully immersed in the storage solution.

Apera Instruments SX620 pH Pen Tester

The Apera Instruments SX620 pH Pen Tester, showing its digital display and probe.

Opération

Mise sous/hors tension

Press the power button (usually marked with a power symbol) to turn the meter on. Press and hold the power button for a few seconds to turn it off.

Étalonnage

For accurate readings, regular calibration is essential. The SX620 features 3-point automatic calibration.

  1. Préparer les solutions d'étalonnage (pH 7.00, pH 4.00, pH 10.01).
  2. Rincez la sonde à l'eau distillée et séchez-la en la tamponnant.
  3. Immerse the probe in the pH 7.00 buffer solution. Press the CAL button. The meter will automatically recognize the solution and calibrate. Wait for the reading to stabilize and indicate completion.
  4. Rinse the probe again.
  5. Immerse the probe in the pH 4.00 buffer solution. Press CAL. Wait for stabilization.
  6. Rinse the probe again.
  7. Immerse the probe in the pH 10.01 buffer solution. Press CAL. Wait for stabilization.
  8. Après un étalonnage réussi en 3 points, l'appareil est prêt à l'emploi.

Mesure du pH

Pour prendre une mesure :

  1. Assurez-vous que l'appareil de mesure est calibré.
  2. Rincez la sonde à l'eau distillée et séchez-la en la tamponnant.
  3. Plonger la sonde dans le sample solution. Ensure the probe tip is fully submerged.
  4. Gently stir the solution to ensure homogeneity.
  5. Wait for the reading on the display to stabilize. The meter will automatically compensate for temperature (ATC).
  6. Relevez les valeurs de pH et de température.
  7. Après la mesure, rincez soigneusement la sonde à l'eau distillée.
Hand holding Apera Instruments SX620 pH Pen Tester in a test tube

The SX620 pH Pen Tester being used to measure pH in a slim test tube, demonstrating its compact design.

Changement d'unité de température

The meter can display temperature in Celsius (°C) or Fahrenheit (°F). Refer to the specific button or menu option in your manual for switching between these units. Typically, this involves a short press of a dedicated button or a combination of buttons.

Entretien

Nettoyage de la sonde

After each use, rinse the probe thoroughly with distilled water to remove any sample residue. Do not wipe the glass bulb, as this can cause static electricity and damage the sensitive membrane. If the probe becomes contaminated with oil or grease, clean it with a mild detergent solution, then rinse thoroughly with distilled water.

Stockage de la sonde

Proper storage is crucial for probe longevity. Always store the probe in 3M KCL storage solution. Ensure the protective cap is filled with storage solution and securely placed over the probe tip. NEVER store the probe in distilled water or deionized water, as this will deplete the reference electrolyte and permanently damage the electrode.

Probe Invalidation Reminder

The meter features an intelligent function that reminds you when the pH probe may need replacement for optimal performance. Pay attention to this reminder and consider replacing the probe if readings become unstable or inaccurate despite proper calibration and cleaning.

Remplacement de la batterie

When the low battery alarm appears on the display, replace the CR2032 lithium batteries promptly to ensure continuous operation and accurate readings.

Dépannage

  • Inconsistent or Unstable Readings: This often indicates a dry or contaminated probe. Rehydrate the probe in 3M KCL storage solution for several hours or overnight. Clean the probe thoroughly. Ensure proper calibration.
  • Le compteur ne s'allume pas : Vérifiez l'installation des piles et assurez-vous qu'elles ne sont pas déchargées. Remplacez-les si nécessaire.
  • Échec de l'étalonnage : Ensure calibration solutions are fresh and not expired. Verify the probe is clean and properly hydrated. Repeat the calibration process carefully.
  • Alarme de batterie faible : Replace the CR2032 lithium batteries immediately.
  • Probe Invalidation Reminder: This indicates the probe's lifespan is nearing its end. Consider replacing the probe for continued accurate performance.

Caractéristiques

Numéro de modèleAI223
plage de pHpH 0.00 - 14.00
Précision du pHpH ± 0.01
Plage de température0 - 60°C (32 - 140°F)
Précision de la température±0.6°C
ÉtalonnageAutomatic 3-point (7.00, 4.00, 10.01)
Compensation automatique de température (ATC)Oui
Source d'énergie2 x CR2032 Lithium Batteries
Indice d'étanchéitéIP57
Dimensions du produit6 x 1 x 1 pouces
Poids de l'article5 onces
FabricantInstruments d'apera
Pays d'origineChine

Garantie et assistance

Apera Instruments products are designed and manufactured to high quality standards. This product is covered by a manufacturer's warranty against defects in materials and workmanship. For specific warranty terms, technical support, or service inquiries, please refer to the warranty card included with your product or visit the official Apera Instruments website.

For assistance, please contact Apera Instruments customer support directly.

Documents connexes - AI223

Préview Testeur de conductivité de poche Apera EC20 : Manuel d’instructions et guide
Manuel d'utilisation complet du testeur de conductivité de poche Apera EC20. Découvrez la configuration, l'étalonnage, la mesure de la conductivité, les spécifications techniques et les informations relatives à la garantie.
Préview Manuel d'utilisation du kit de test de pH Apera Instruments PH1 Value
Manuel d'utilisation du kit de testeur de pH Apera Instruments PH1 Value. Ce manuel fournit des instructions détaillées sur l'installation, l'étalonnage, la mesure, le paramétrage, les caractéristiques techniques, l'entretien de la sonde, le dépannage, le remplacement des piles et les informations relatives à la garantie.
Préview Manuel d'utilisation du stylo testeur de pH de sol Apera GroStar GS2 Premium | Tests de sol précis
Manuel d'utilisation complet du testeur de pH du sol Apera GroStar GS2 Premium. Découvrez comment l'étalonnage, la mesure, le dépannage et l'entretien pour des tests de pH du sol précis.
Préview PH8500 Portable pH Meter User Manual - Apera Instruments
User manual for the Apera PH8500 portable pH meter. Covers features, specifications, operation, calibration, maintenance, and data management for accurate pH testing in various applications.
Préview Apera Instruments PC60 Premium Multi-Parameter Tester Instruction Manual
Comprehensive instruction manual for the Apera Instruments PC60 Premium Multi-Parameter Tester, covering battery installation, keypad functions, preparation, pH and conductivity calibration and measurement, parameter settings, technical specifications, icons, probe replacement, and warranty information.
Préview Manuel d'utilisation du kit de test de pH Apera Instruments PH20 Value
Manuel d'utilisation complet pour le kit de testeur de pH Apera Instruments PH20 Value, couvrant l'installation de la batterie, les fonctions du clavier, l'étalonnage, la mesure, les réglages des paramètres, le dépannage, les spécifications techniques et les informations de garantie.