The XPOWER FC-100 is a heavy-duty industrial high-velocity whole room air mover and circulator utility floor fan designed for efficient air movement. It is ideal for drying, cooling, and ventilation in various environments, including homes, offices, workshops, and garages. This unit combines powerful performance with convenient features for versatile use.

  • Puissant et efficace : Delivers 1100 CFM (Cubic Feet Per Minute) while consuming only 0.6 Amps. Features an advanced high-torque motor and a unique grille design for focused airflow up to 120+ feet.
  • Convenient & Versatile: Equipped with 4 adjustable speeds, a 3-hour set-and-forget timer, and a grab-and-go handle. Its durable housing and heavy-duty wrap-around cord design ensure longevity and ease of transport. The unit is fully assembled, requires low maintenance, and is stackable for compact storage.
  • Technologie avancée : Incorporates a powerful high-torque induction motor, a unique spiral grille, exclusive fan blade technology, and 360-degree directional airflow capabilities.
  • Safety & Service Standards: ETL / CETL safety certified, ensuring compliance with recognized safety standards. It includes a 1-year limited warranty, backed by XPOWER’s California-based customer service team for comprehensive support.
XPOWER FC-100 Air Mover, front view

Figure 1 : Face avant view of the XPOWER FC-100 Air Mover, showcasing its compact design and powerful fan blades.

Installation

The XPOWER FC-100 Air Mover comes fully assembled and ready for use. Follow these simple steps to set up your unit:

  1. Déballer: Retirez délicatement le ventilateur de son emballage.
  2. Placement: Place the unit on a stable, flat surface. Ensure there is adequate space around the fan for optimal airflow.
  3. Connexion électrique : Unwind the power cord from the integrated wrap-around design. Plug the power cord into a standard 120V AC electrical outlet.
  4. Ajuster la direction : Utilize the adjustable stand to tilt the fan to your desired angle for targeted airflow. The unit supports 360-degree rotation.
XPOWER FC-100 Air Mover, front view avec support

Figure 2: The XPOWER FC-100 Air Mover positioned on its sturdy stand, ready for operation.

Mode d'emploi

The XPOWER FC-100 offers intuitive controls for easy operation.

Contrôle de puissance et de vitesse

  1. Allumer: Locate the speed control knob on the unit. Turn the knob clockwise from the 'OFF' position to select one of the four available speeds (1, 2, 3, or 4).
  2. Régler la vitesse : Rotate the knob to increase or decrease the fan speed as needed. Speed 1 is the lowest setting, and Speed 4 is the highest.
  3. Éteindre: Rotate the speed control knob counter-clockwise to the 'OFF' position.

Fonction de minuterie

The integrated 3-hour timer allows you to set the unit to operate for a specific duration.

  1. Régler la minuterie: Locate the timer knob. Rotate the knob clockwise to set the desired operating time (up to 180 minutes, or 3 hours).
  2. Fonctionnement continu : To operate the fan continuously without a timer, set the timer knob to the 'ON' position.
  3. Arrêt automatique: The unit will automatically turn off once the set timer duration has elapsed.

Directional Airflow

The XPOWER FC-100 features a 360-degree directional airflow design, allowing you to precisely target air movement.

  • Régler l'inclinaison : Loosen the adjustment knobs on the sides of the fan's stand. Tilt the fan body to the desired angle.
  • Position sécurisée : Tighten the adjustment knobs firmly to secure the fan in place.
  • Optimal Circulation: For whole-room circulation, position the fan to bounce air off walls or ceilings. For drying, direct the airflow directly at the target area.
XPOWER FC-100 Air Mover side view with rotation arrows

Figure 3 : Côté view of the XPOWER FC-100, illustrating its 360-degree rotational capability for versatile airflow direction.

Diagram showing focused airflow up to 120 feet

Figure 4: Diagram demonstrating the focused and extended airflow of the FC-100, reaching distances of up to 120 feet.

Diagram showing air recirculation for drying

Figure 5: Illustration of how the FC-100 recirculates air to create a gentle and consistent stream, shortening drying times.

Entretien

The XPOWER FC-100 is designed for low maintenance. Regular cleaning will ensure optimal performance and longevity.

  1. Débrancher l'alimentation : Débranchez toujours l'appareil de la prise de courant avant d'effectuer toute opération de maintenance.
  2. Nettoyage extérieur : Essuyez l'extérieur de l'appareil avec un chiffon doux.amp tissu. Évitez d'utiliser des produits chimiques agressifs ou des nettoyants abrasifs.
  3. Nettoyage des grilles : Periodically inspect the intake and exhaust grilles for dust, debris, or obstructions. Use a vacuum cleaner with a brush attachment or a soft brush to gently remove any buildup. Do not insert fingers or foreign objects into the grilles.
  4. Rangement du cordon : Utilize the integrated wrap-around cord design for neat and secure storage of the power cord when the unit is not in use.

Dépannage

If you encounter any issues with your XPOWER FC-100, refer to the following common troubleshooting steps:

  • L'appareil ne s'allume pas :
    • Assurez-vous que le cordon d'alimentation est correctement branché dans une prise électrique fonctionnelle.
    • Check if the speed control knob is turned to an active speed setting (1-4) and not in the 'OFF' position.
    • Verify that the timer is not set to '0' or has not expired. Set it to 'ON' for continuous operation or to a desired time.
    • Check your circuit breaker or fuse box to ensure the outlet has power.
  • Débit d'air réduit :
    • Inspect the intake and exhaust grilles for any obstructions (dust, lint, debris). Clean as described in the Maintenance section.
    • Ensure the fan is operating at a higher speed setting if more airflow is desired.
  • Bruit ou vibration inhabituel :
    • Veillez à placer l'appareil sur une surface stable et plane.
    • Check for any loose parts or foreign objects inside the fan grilles. Disconnect power before inspecting.

Si ces étapes ne résolvent pas le problème, veuillez contacter le service client XPOWER pour obtenir de l'aide supplémentaire.

Caractéristiques

FonctionnalitéSpécification
MarquePuissance X
Nom du modèleCirculateur d'air
Numéro de modèle de l'articleFC-100
Capacité de débit d'air1100 pieds cubes par minute (CFM)
Nombre de niveaux de puissance4
Minuteur3-hour (180 minutes)
Source d'énergieAC
Quoitage69 watts
Voltage220 volts
Poids de l'article9.7 livres
Dimensions du produit16.1"P x 14.2"L x 8.9"H
Conception de ventilateur électriqueVentilateur de plancher
Type de chambreBureau à domicile
Utilisations recommandéesAir Circulation, Drying, Ventilating
Certification de sécuritéETL / CETL

Garantie et assistance

The XPOWER FC-100 Air Mover comes with a Garantie limitée de 1 ans from the manufacturer, XPOWER Manufacture, Inc. This warranty covers defects in materials and workmanship under normal use.

For any warranty claims, technical support, or customer service inquiries, please contact XPOWER’s California-based customer service team. They are dedicated to providing comprehensive support and ensuring a first-class customer experience.

Vous trouverez plus d'informations et les coordonnées en visitant le site officiel. XPOWER Store on Amazon.

Documents connexes - FC-100

Préview Manuel d'utilisation et spécifications du circulateur d'air XPOWER série FC
Manuel d'utilisation complet et spécifications techniques des circulateurs d'air XPOWER série FC (FC-100, FC-200, FC-250D, FC-250AD, FC-300, FC-420). Comprend les consignes de sécurité, le guide d'installation, le fonctionnement, l'entretien, le dépannage et les informations sur la garantie.
Préview Manuel d'utilisation et spécifications du circulateur d'air XPOWER
Manuel d'utilisation complet et spécifications techniques des circulateurs d'air XPOWER, modèles FC-100, série FC-200, FC-300 et FC-420. Comprend les consignes de sécurité, la description des pièces, le guide d'installation et d'utilisation, les informations sur l'entretien, le dépannage et la garantie.
Préview Manuel d'utilisation du ventilateur brumisateur/circulateur d'air rechargeable XPOWER
Manuel d'utilisation complet pour les circulateurs d'air et ventilateurs brumisateurs rechargeables XPOWER (modèles FC-125B, FC-150B, FM-65B, FM-65WB, FT-65WB), couvrant les consignes de sécurité, les éléments inclus, la présentation du produit, la description des pièces, l'installation, le fonctionnement, le raccordement à la source d'eau, la charge, l'entretien, le dépannage et les spécifications techniques.
Préview XPOWER P-200T/P-200AT/P-230AT Professional Air Mover Owner's Manual
Comprehensive owner's manual for XPOWER P-200T, P-200AT, and P-230AT professional air movers, covering operation, safety, maintenance, specifications, and warranty.
Préview Manuel d'utilisation du ventilateur brumisateur/circulateur d'air rechargeable XPOWER
Ce manuel fournit des instructions complètes pour l'utilisation, l'entretien et le dépannage des circulateurs d'air et ventilateurs brumisateurs rechargeables XPOWER. Il aborde les consignes de sécurité, l'identification des pièces, l'installation, l'utilisation des différents modèles (FC-125B, FC-150B, FM-65B, FM-65WB, FT-65WB), l'entretien de la batterie, les spécifications techniques et les informations relatives à la garantie.
Préview Manuel d'utilisation du ventilateur brumisateur/circulateur d'air rechargeable XPOWER | FC-125B, FC-150B, FM-65B, FM-65WB, FT-65WB
Manuel d'utilisation complet pour les circulateurs d'air et ventilateurs brumisateurs rechargeables XPOWER (modèles FC-125B, FC-150B, FM-65B, FM-65WB, FT-65WB). Contient les consignes de sécurité, les guides d'utilisation, les conseils d'entretien, le dépannage et les spécifications techniques.