1. Produit terminéview

The Fill-Rite KIT120FLG is a 1-inch meter flange assembly kit designed for use with Fill-Rite FR4200 and FR4400 series pumps. This kit provides essential components for mounting a meter, serving as a cost-effective solution for pump repair and extending equipment lifespan. It includes certified OEM parts to ensure compatibility and reliable performance.

This kit replaces the older 305F0998 flange.

1.1 Contenu du paquet

The KIT120FLG package typically includes the following components:

  • Meter Flange (Red, as shown in image)
  • Joint torique
  • Bolts (for attaching the meter to the flange)
Fill-Rite KIT120FLG components: red meter flange, O-ring, and various bolts.

Figure 1 : Components of the Fill-Rite KIT120FLG kit, including the red flange, O-ring, and bolts.

2. Consignes de sécurité

Always observe the following safety precautions when handling, installing, or maintaining the KIT120FLG meter flange assembly:

  • Ensure the pump system is de-pressurized and drained before beginning any installation or maintenance.
  • Disconnect power to the pump to prevent accidental operation.
  • Portez un équipement de protection individuelle (EPI) approprié, tel que des lunettes de sécurité et des gants.
  • Refer to the main pump manual for specific safety guidelines related to your FR4200 or FR4400 series pump.
  • Manipulez les composants avec précaution afin d'éviter tout dommage ou blessure.

3. Instructions d'installation

Follow these steps to properly install the KIT120FLG meter flange assembly:

  1. Préparer la pompe : Ensure the FR4200 or FR4400 series pump is turned off, de-pressurized, and any fuel or fluid lines are disconnected from the area where the flange will be installed.
  2. Remove Existing Flange (if applicable): If replacing an old flange, carefully remove the existing bolts and flange, ensuring no debris enters the pump or lines.
  3. Position the O-Ring: Place the O-ring onto the meter side of the new KIT120FLG flange. Ensure it is seated correctly to create a proper seal.
  4. Connect to Pump Discharge: Using a pipe nipple (not included), connect the inlet of the meter flange to the pump's discharge port. Ensure a secure, leak-free connection.
  5. Compteur de fixation : Align the meter (not included) with the flange. Use the provided bolts (typically four) to securely attach the meter to the flange. Tighten bolts evenly to prevent stress on the components and ensure a tight seal.
  6. Inspecter les connexions : Vérifiez à nouveau toutes les connexions pour le serrage et le bon alignement.
  7. Test de fuites : After installation, slowly re-pressurize the system and carefully inspect for any leaks around the flange and meter connections. Address any leaks immediately.
Diagram showing the assembly of the meter flange, O-ring, and bolts, with labels for meter side and pump discharge connection.

Figure 2 : Explosé view diagram illustrating the assembly of the KIT120FLG meter flange, O-ring, and bolts for connection to a meter and pump discharge.

4. Fonctionnement

Once properly installed, the KIT120FLG meter flange assembly facilitates the connection of a compatible meter to your Fill-Rite FR4200 or FR4400 series pump. The flange ensures a secure and sealed pathway for fluid transfer, allowing the connected meter to accurately measure the dispensed volume. Operation of the meter itself will depend on the specific meter model used.

5. Entretien

Regular maintenance of the meter flange assembly ensures optimal performance and longevity:

  • Inspection périodique: Regularly inspect the flange, O-ring, and bolts for any signs of wear, corrosion, or damage. Check for leaks around the connections.
  • Remplacement du joint torique : The O-ring is a critical sealing component. Replace it if it shows signs of cracking, hardening, or compression set, or if leaks are detected.
  • Nettoyage: Keep the exterior of the flange clean from dirt, debris, and fluid residue.
  • Étanchéité des boulons : Periodically check the tightness of the bolts securing the meter to the flange. Do not overtighten.

6. Dépannage

If you encounter issues with your KIT120FLG meter flange assembly, consider the following:

Problème Cause possible Solution
Fuite de liquide Damaged or improperly seated O-ring; loose bolts; damaged flange. Ensure O-ring is correctly positioned and undamaged. Tighten bolts evenly. Inspect flange for cracks or damage; replace if necessary.
Meter not seating properly Misalignment; debris in connection; damaged threads. Re-align meter and flange. Clean connection surfaces. Inspect threads for damage.

7. Spécifications

Fonctionnalité Détail
Numéro de modèle KIT120FLG
Type de produit Mechanical Component (Meter Flange Assembly Kit)
Compatibilité Fill-Rite FR4200 and FR4400 Series Pumps
Taille de la bride 1 pouces
Matériel Aluminium
Dimensions du colis 4.72 x 3.62 x 3.35 pouces (environ 12.0 x 9.2 x 8.5 cm)
Poids du colis 0.324 kg (environ 11.4 oz)
Pays d'origine États-Unis

8. Garantie et assistance

Fill-Rite provides certified OEM parts, ensuring quality and compatibility. For specific warranty information regarding the KIT120FLG or your Fill-Rite pump, please refer to the documentation provided with your original pump purchase or contact Fill-Rite customer support directly.

For technical assistance or to inquire about replacement parts, please visit the official Fill-Rite website ou contactez leurs centres de service agréés.

Documents connexes - KIT120FLG

Préview Pompe de transfert de carburant Fill-Rite SD1202H : Instructions d’installation et d’utilisation
Instructions complètes d'installation et d'utilisation de la pompe de transfert de carburant Fill-Rite SD1202H 12 V CC, incluant les pièces, les schémas de câblage et les consignes de sécurité. Compatible avec les modèles FR1200, FR2400, FR4200, FR4400, FR600, SD1200 et SD600.
Préview Manuel d'installation et d'utilisation des pompes de transfert de carburant Fill-Rite série H
Guide complet des pompes de transfert de carburant Fill-Rite série H (FR1200, FR2400, FR4200, FR4400, FR600, SD1200, SD600) : installation, fonctionnement, sécurité, dépannage, spécifications et accessoires. Instructions de câblage CC et CA incluses.
Préview Pompes de transfert de carburant CA Fill-Rite séries NX25-120 et NX25-240 : Manuel d’installation et d’utilisation
Manuel complet d'installation et d'utilisation des pompes de transfert de carburant CA Fill-Rite séries NX25-120 et NX25-240. Ce manuel couvre la sécurité, l'installation, le fonctionnement, l'entretien et les informations spécifiques à chaque modèle.
Préview Fill-Rite FR20V, FRHP32V, FRAP32V Hand and Air Operated Pumps Installation and Operation Manual
Comprehensive installation and operation manual for Fill-Rite FR20V, FRHP32V, and FRAP32V hand and air-operated fuel transfer pumps. Covers safety precautions, installation procedures, troubleshooting, technical specifications, fluid compatibility, and warranty information.
Préview Manuel d'installation et d'utilisation de la pompe de transfert DEF Fill-Rite série DF
Comprehensive installation and operation manual for the Fill-Rite DF Series DEF Transfer Pump. Covers safety, product information, installation steps for IBC/Tote and Drum/Barrel setups, electrical wiring, pump operation, troubleshooting, and parts lists.
Préview Fill-Rite Product Warranty Policy - Coverage and Duration
Comprehensive warranty policy from Fill-Rite, detailing coverage periods and terms for various product series purchased before and after July 1, 2019, including component-specific warranties and exclusions.