Allanson 2260-TP

Allanson Industrial Gas Ignitor

Model: 2260-TP

1. Introduction

This manual provides essential information for the safe and effective installation, operation, and maintenance of the Allanson Industrial Gas Ignitor, Model 2260-TP. This electronic ignition transformer is designed for industrial gas applications, providing reliable ignition for various heating systems.

Allanson Industrial Gas Ignitor Model 2260-TP

Figure 1 : Allanson Industrial Gas Ignitor Model 2260-TP. This image displays the black rectangular electronic ignition transformer with a white label. The label clearly shows 'Allanson ELECTRONIC IGNITION TRANSFORMER CAT No. 2260-TP', along with primary and secondary voltage/current ratings. It also indicates 'MADE IN CANADA'. Electrical wires are visible, connected to one side of the unit.

2. Consignes de sécurité

AVERTISSEMENT: Installation and servicing of this ignitor must be performed by a qualified and licensed professional. Failure to follow these instructions could result in property damage, personal injury, or death.

3. Produit terminéview

The Allanson 2260-TP is an electronic ignition transformer designed to provide a high-voltage spark for igniting gas in industrial heating systems. It converts standard line voltage à un volume élevétage output, ensuring reliable and efficient ignition.

Caractéristiques principales :

4. Configuration et installation

Avant de commencer :

  1. Ensure the power supply matches the ignitor's specifications (120V, 50/60Hz).
  2. Confirm the ignitor is compatible with your specific heating system.
  3. Gather necessary tools: screwdrivers, wire strippers, multimeter, mounting hardware.

Étapes d'installation :

  1. Coupure de courant : Turn off all power to the heating system at the main circuit breaker. Verify power is off using a multimeter.
  2. Remove Old Ignitor (if applicable): Carefully disconnect wiring and mounting hardware from the existing ignitor. Note wire connections for reference.
  3. Montage: Securely mount the Allanson 2260-TP ignitor in the designated location using appropriate hardware. Ensure it is stable and free from vibration.
  4. Câblage : Connect the primary (input) wires to the 120V AC power supply according to the wiring diagram of your appliance. Connect the secondary (output) wires to the spark electrode or ignition rod. Ensure all connections are tight and insulated. Refer to the label on the ignitor for specific primary and secondary connections.
  5. Mise à la terre : Ensure the ignitor and the appliance are properly grounded.
  6. Vérifications finales : Double-check all wiring connections. Ensure no loose wires or potential short circuits.

5. Mode d'emploi

The Allanson 2260-TP ignitor operates automatically as part of the heating system's control sequence. Once properly installed and wired, it will generate a high-voltage spark when called upon by the system's control board to ignite the gas burner.

Opérer:

  1. Ensure all installation steps are completed and verified.
  2. Rétablir l'alimentation électrique du système de chauffage.
  3. Initiate a call for heat from the thermostat or control system.
  4. Observe the ignitor's operation. It should produce a visible spark at the electrode, leading to gas ignition.
  5. If ignition does not occur, refer to the Troubleshooting section.

6. Entretien

The Allanson 2260-TP ignitor is designed for long-term reliability with minimal maintenance. However, periodic inspection of the entire ignition system is recommended as part of routine appliance servicing.

7. Dépannage

If the ignitor is not functioning correctly, perform the following checks. Always disconnect power before inspecting components.

Problème Cause possible Solution
No Spark from Ignitor
  • Aucun pouvoir d'allumage.
  • Connexion électrique défectueuse.
  • Allumeur défectueux.
  • Tableau de commande défectueux.
  • Vérifiez le disjoncteur et l'alimentation électrique.
  • Vérifiez que tous les branchements électriques sont bien fixés.
  • Test ignitor for proper voltage output (requires specialized equipment and knowledge).
  • Consult appliance manual for control board diagnostics.
Intermittent Spark/Ignition
  • Connexions de câblage desserrées.
  • Dirty or worn spark electrode.
  • Alimentation électrique fluctuante.
  • Serrez toutes les connexions électriques.
  • Clean or replace the spark electrode.
  • Have an electrician check the power supply.
Ignitor Sparks but No Gas Ignition
  • Pas d'alimentation en gaz.
  • Soupape de gaz défectueuse.
  • Blocked burner orifice.
  • Éclat d'étincelle incorrect.
  • Check gas supply to the appliance.
  • Test gas valve operation.
  • Clean burner orifices.
  • Adjust spark gap according to appliance specifications.

If problems persist after troubleshooting, contact a qualified HVAC technician or the manufacturer for assistance.

8. Spécifications

Attribut Valeur
Fabricant Allanson
Numéro de pièce 2260-TP
Poids de l'article 7 livres
Quantité du paquet d'articles 1
Vol principaltage/Courant 120 V 50/60 Hz 0.6 A
Vol secondairetage/Courant 15.6 kVpk 28 mA
Date de première disponibilité 18er août 2017

9. Garantie et assistance

Specific warranty information for the Allanson Industrial Gas Ignitor #2260-TP is not provided in this manual. For details regarding warranty coverage, terms, and conditions, please refer to the documentation included with your purchase or contact Allanson directly through their official websites ou canaux de service client.

For technical support or further assistance, please reach out to a qualified HVAC professional or the manufacturer's support team.

Documents connexes - 2260-TP

Préview Manuel d'utilisation des allumeurs électroniques Allanson série 2260
Manuel d'instructions complet pour les allumeurs électroniques Allanson série 2260 (modèles 2260-TP, 2260-TPLP, 2260-TW, 2260-TWLP, 2260-P, 2260-TPLPJB). Comprend les instructions d'installation, de maintenance, de test et les spécifications mécaniques pour les applications gaz commerciales et industrielles.
Préview Manuel d'utilisation de l'allumeur électronique Allanson OMNI type 2275U
Manuel d'instructions pour l'allumeur électronique Allanson OMNI, type 2275U, fournissant des détails d'application, des spécifications, des procédures d'installation, de maintenance et de test pour un allumage fiable dans les systèmes à gaz et à pétrole.
Préview Guide de spécifications de l'allumeur électronique Allanson OMNI 2270U-3ST
Guide technique détaillé de l'allumeur électronique universel Allanson OMNI 2270U-3ST, doté d'une minuterie intégrée de 3 secondes et d'un outil de diagnostic pour les systèmes de brûleurs à mazout. Comprend les spécifications techniques, les dimensions et les coordonnées.
Préview Guide de spécifications de l'allumeur électronique universel Allanson 2270U-3ST OMNI
Guide de spécifications détaillé pour l'allumeur électronique universel Allanson 2270U-3ST OMNI, doté d'une minuterie intégrée de 3 secondes et de capacités de diagnostic pour les systèmes de brûleurs à mazout.
Préview Transformateurs à gaz industriels Allanson : Spécifications et guide de correspondance
Spécifications détaillées et tableaux de correspondance pour les transformateurs de gaz industriels Allanson, couvrant des modèles comme le 1092-H, le 1092-PF-G et d'autres, avec des informations de compatibilité pour divers fabricants de brûleurs.
Préview Allanson ACL-SC-DMX DMX Sub-Controller Installation Manual
This installation manual provides detailed instructions for the Allanson ACL-SC-DMX DMX Sub-Controller, covering specifications, port configurations, wiring diagrams, and important safety precautions for RGBW lighting systems.