Hager ADC810H Residual Current Circuit Breaker with Overcurrent Protection (RCBO) User Manual

Modèle: ADC810H | Marque : Hager

1. Introduction

The Hager ADC810H is a compact and reliable Residual Current Circuit Breaker with Overcurrent Protection (RCBO), designed for the protection of electrical installations against both overcurrents (overload and short-circuit) and earth leakage currents. This device is a bipolar 1P+N unit, suitable for single-phase systems, ensuring enhanced safety and operational flexibility. Its design facilitates easy installation in industrial and domestic environments, providing precise monitoring of differential currents.

2. Consignes de sécurité

WARNING: Electrical work should only be performed by qualified and authorized personnel. Failure to follow these instructions can result in serious injury or death.

  • Always disconnect the main power supply before installing, maintaining, or troubleshooting the device.
  • Assurez-vous d'une mise à la terre correcte du système électrique.
  • Verify that the device ratings (voltage, current, breaking capacity) match the requirements of your electrical installation.
  • N’utilisez pas l’appareil s’il semble endommagé.
  • Regularly test the residual current function using the test button.

3. Produit terminéview

The Hager ADC810H RCBO integrates both overcurrent and residual current protection in a single compact unit. It features a robust housing and clear markings for easy identification and connection.

Hager ADC810H RCBO front view avec bornes

Cette image montre la face avant. view of the Hager ADC810H Residual Current Circuit Breaker with Overcurrent Protection (RCBO). Visible are the toggle switch for manual operation, the test button, and the connection terminals for phase and neutral conductors.

Les principaux composants comprennent :

  • Interrupteur à bascule: For manual ON/OFF operation and indication of trip status.
  • Bouton de test : Used to periodically test the residual current tripping mechanism.
  • Bornes de connexion : Clearly marked for phase (L) and neutral (N) input and output.
  • DIN Rail Mounting Clip: For secure installation on a DIN rail.

4. Installation

The Hager ADC810H RCBO is designed for DIN rail mounting. Follow these steps for safe and correct installation:

  1. Coupure de courant : Ensure the main power supply to the installation is completely disconnected and secured against accidental re-connection.
  2. Montage: Clip the RCBO onto the DIN rail in the consumer unit or distribution board. Ensure it is securely seated.
  3. Wiring - Input: Connect the incoming phase (L) and neutral (N) conductors to the upper terminals of the RCBO. Ensure correct polarity and tight connections.
  4. Wiring - Output: Connect the outgoing phase (L) and neutral (N) conductors to the lower terminals of the RCBO, leading to the protected circuit. Ensure correct polarity and tight connections.
  5. Couple: Tighten all terminal screws to the manufacturer's specified torque to prevent loose connections and overheating.
  6. Vérification: Double-check all connections for correctness and security before restoring power.

5. Fonctionnement

The RCBO operates automatically to protect against electrical faults. Manual operation is also possible:

  • Mise sous tension : Poussez l'interrupteur à bascule vers le haut jusqu'à la position « ON ».
  • Éteindre: Poussez l'interrupteur à bascule vers le bas jusqu'à la position « ARRÊT ».
  • Déclenchement automatique : In the event of an overcurrent (overload or short-circuit) or an earth leakage current exceeding 30mA, the RCBO will automatically trip, moving the toggle switch to the 'OFF' or intermediate position.
  • Fonction d'essai : Press the 'T' (Test) button periodically (e.g., monthly) to verify the residual current tripping mechanism. The RCBO should trip immediately. If it does not trip, the device may be faulty and requires replacement.

6. Entretien

The Hager ADC810H RCBO requires minimal maintenance, but regular checks are essential for continued safety and performance:

  • Inspection visuelle : Inspectez périodiquement l'appareil afin de détecter tout signe de dommage physique, de décoloration ou de connexions desserrées.
  • Test Button Operation: Perform the test button operation monthly as described in the 'Operation' section.
  • Nettoyage: If necessary, clean the exterior of the device with a dry, soft cloth. Do not use abrasive cleaners or solvents.
  • Contrôle professionnel : It is recommended to have the entire electrical installation, including protective devices, inspected by a qualified electrician at regular intervals as per local regulations.

7. Dépannage

If the RCBO trips unexpectedly or fails to operate correctly, consider the following:

  • RCBO Trips Immediately After Reset:
    • Cause possible : Persistent earth fault or short-circuit in the protected circuit.
    • Solution: Disconnect all loads from the circuit. If the RCBO still trips, there is a fault in the fixed wiring. If it holds, reconnect loads one by one to identify the faulty appliance. Consult a qualified electrician.
  • RCBO Trips Intermittently:
    • Cause possible : Intermittent earth fault, overloaded circuit, or faulty appliance.
    • Solution: Reduce the load on the circuit. Check appliances for intermittent faults.
  • RCBO Does Not Trip When Test Button is Pressed:
    • Cause possible : Faulty RCBO.
    • Solution: The device is not providing residual current protection and must be replaced immediately by a qualified electrician.
  • No Power to Circuit, RCBO is ON:
    • Cause possible : Loose connection, fault upstream (e.g., main breaker tripped), or internal device failure.
    • Solution: Check all connections. Verify power supply to the RCBO. If issues persist, consult a qualified electrician.

8. Spécifications techniques

ParamètreValeur
MarqueHager
Numéro de modèleADC810H
TaperRCBO (Residual Current Circuit Breaker with Overcurrent Protection)
Polonais1P+N (Bipolar Phase Neutral)
Vol évaluétage (Vca)230 V
Fréquence50/60 Hz
Courant nominal10 A
Rated Residual Operating Current (IΔn)30 mA (0.03A)
Pouvoir de coupure4.5 kA
Overcurrent Trip CurveC
Magnetic Trip Range5 à 10 po
Type of Residual Current UnitAC (for alternating current only)
Degré de protectionIP20
Type d'installationRail DIN
Nombre de modules2
Dimensions (environ)10 x 7 x 4 cm
Poids (environ)500 g

9. Informations sur la garantie

Hager products are manufactured to high-quality standards and are covered by a manufacturer's warranty against defects in materials and workmanship. The specific terms and duration of the warranty may vary by region and product. Please refer to the official Hager website or contact your local supplier for detailed warranty information applicable to your purchase. Keep your proof of purchase for warranty claims.

10. Assistance et contact

For technical assistance, product inquiries, or support, please contact Hager customer service or your authorized Hager distributor. You can typically find contact information on the official Hager website or on the product packaging. When contacting support, please have your product model number (ADC810H) and any relevant purchase details ready.

Hager Officiel Website: www.hager.com

Documents connexes - ADC810H

Préview Guide d'installation et d'utilisation du disjoncteur différentiel Hager ADC932R
Ce guide fournit les informations essentielles pour l'installation et l'utilisation du disjoncteur différentiel Hager ADC932R avec neutre commuté. Il aborde le raccordement électrique, le montage, les tests et des conseils d'application spécifiques, notamment pour les bornes de recharge de véhicules électriques.
Préview Disjoncteur différentiel Hager RCBO avec neutre commuté (6-32 A) - Guide d'installation et d'utilisation
Ce document fournit des instructions d'installation et d'utilisation pour le disjoncteur différentiel Hager (RCBO) avec neutre commuté, couvrant les modèles de 6 à 32. AmpCe document détaille les connexions électriques, le montage, les tests et les notes d'application spécifiques pour EVCS.
Préview Manuel d'installation et d'utilisation du disjoncteur différentiel Hager
Guide complet pour l'installation et l'utilisation des disjoncteurs différentiels Hager (RCBO), y compris les connexions électriques, le montage, les tests et des conseils spécifiques pour les applications EVCS.
Préview Guide d'application des disjoncteurs différentiels Hager : garantir une installation correcte
Guide Hager sur l'application des disjoncteurs différentiels (RCBO), abordant les problèmes liés à la commutation du neutre et aux disjoncteurs unidirectionnels, et proposant des solutions pour une installation correcte et le choix du produit. Inclut les caractéristiques techniques des modèles ADC920R et ADA920U.
Préview Hager Residual Current Breakers Operated RCBO 6-50A Installation and Safety Guide
This document provides installation instructions and safety warnings for Hager Residual Current Breakers Operated RCBO 6-50A. It details warranty information, electrical diagrams, and operational procedures for qualified contractors.
Préview Hager Consumer Unit AFDD Installation Guidance Notes for RCBO and MCB
Comprehensive installation guidance notes from Hager for Consumer Unit AFDD Single Mod, covering RCBO and MCB devices, switch disconnectors, and dual RCCB units. Includes retrofitting information and rating derating guidelines for electrical installations.