Sloan SF-2150

Manuel d'utilisation du robinet sans contact à capteur Sloan SF-2150

Modèle : SF-2150

1. Plus deview

The Sloan SF-2150 Sensor Activated Touch-Free Faucet provides a hygienic and water-efficient solution for commercial restrooms. This deck-mounted faucet features an infrared sensor for touchless activation, promoting cleanliness and reducing water consumption. Its robust commercial-grade construction ensures durability and long-term performance.

Caractéristiques principales :

  • Touch-Free Activation: Reliable infrared sensor for hygienic operation.
  • Water-Saving Efficiency: Delivers a low flow rate of 0.5 gallons per minute (GPM).
  • Adjustable Sensor Range: Customize sensing distance to suit specific needs.
  • Durabilité de qualité commerciale : Constructed with robust materials for high-traffic environments.
  • Installation et maintenance faciles : Designed for straightforward setup and accessible servicing.
  • Filtered Solenoid: Includes a serviceable strainer filter for clean water supply.
  • Conforme à l'ADA: Meets Americans with Disabilities Act requirements for accessibility.
Sloan SF-2150 Sensor Activated Touch-Free Faucet
Figure 1.1: Sloan SF-2150 Sensor Activated Touch-Free Faucet, Polished Chrome Finish.

Vidéo du produit

Cette vidéo offre un aperçu généralview of Sloan SF Faucets, highlighting their features and benefits in commercial settings.

2. Consignes de sécurité

Read all instructions carefully before installation and operation. Failure to follow these instructions may result in property damage, personal injury, or product malfunction.

  • Coupez toujours l'arrivée d'eau principale avant de commencer toute installation ou opération de maintenance.
  • Ensure all electrical connections (for battery power) are secure and correctly installed according to local codes.
  • N’utilisez pas de nettoyants abrasifs ni de produits chimiques agressifs sur la finition du robinet, car cela pourrait l’endommager.
  • Gardez les piles hors de portée des enfants. Jetez les piles usagées de manière responsable.
  • If you are unsure about any part of the installation or maintenance process, consult a qualified plumber or electrician.

3. Contenu du colis

Vérifiez que tous les composants sont présents avant de commencer l'installation :

  • Sloan SF-2150 Faucet Body (Polished Chrome)
  • Boîtier de commande avec solénoïde filtré
  • Câble de capteur de 36 pouces
  • Tuyau flexible de 24 pouces
  • Four (4) AA Batteries (included)
  • Mounting Hardware (gasket, washer, mounting nut, mounting screw)
  • Back-Check Tee (if applicable to your model)
Interne view of the Sloan SF-2150 control box with wiring and solenoid
Figure 3.1 : Interne view of the control box, showing wiring and solenoid valve.
Extérieur view of the Sloan SF-2150 control box with model number and technical support information
Figure 3.2: Exterior of the control box, indicating model SF2150 and technical help contact.

4. Instructions d'installation

This section outlines the steps for installing your Sloan SF-2150 faucet. Ensure the water supply is turned off before proceeding.

4.1. Préparer la surface de montage

  1. Ensure the mounting surface (deck) is clean and free of debris.
  2. Confirm the mounting hole is appropriately sized for the faucet body.

4.2. Installez le corps du robinet

  1. Place the faucet body through the mounting hole on the deck.
  2. From underneath the deck, place the rubber gasket, metal washer, and mounting nut onto the faucet shank.
  3. Secure the faucet body by tightening the mounting nut with the provided mounting screw. Do not overtighten.
Sloan SF-2150 Faucet with mounting hardware visible from underneath the deck
Figure 4.1: Faucet body with mounting hardware for deck installation.

4.3. Connect Water Supply and Sensor Cable

  1. Connect the 24-inch flex hose from the faucet body to the water supply line. Use appropriate plumbing tape or sealant as needed.
  2. Connect the 36-inch sensor cable from the faucet body to the designated port on the control box.
  3. Mount the control box in an accessible location under the sink, ensuring it is secure and protected from moisture.

4.4. Installez les piles

  1. Open the battery compartment on the control box.
  2. Insert the four (4) AA batteries, ensuring correct polarity.
  3. Fermez soigneusement le compartiment à piles.

4.5. Dernières étapes

  1. Ouvrez lentement l'arrivée d'eau principale et vérifiez s'il y a des fuites.
  2. Test the faucet operation by placing hands within the sensor range.

5. Mode d'emploi

The Sloan SF-2150 faucet is designed for simple, touch-free operation.

5.1. Activation automatique

The faucet activates automatically when hands are placed within the sensor's detection zone. Water will flow for a preset duration or until hands are removed from the sensor's range.

Côté view of Sloan SF-2150 Faucet showing the sensor window
Figure 5.1 : Côté view of the faucet, highlighting the infrared sensor window.

5.2. Adjustable Infrared Sensor Range

The infrared sensor range can be adjusted to optimize performance for different sink depths and user preferences. Refer to the control box for specific instructions on adjusting the sensor range. Typically, this involves pressing a button or turning a dial on the control box to cycle through different sensitivity settings.

6. Entretien

Un entretien régulier garantit des performances optimales et une longue durée de vie à votre robinet Sloan SF-2150.

6.1. Nettoyage du robinet

  • Clean the polished chrome finish with a soft cloth and mild, non-abrasive soap and water.
  • Avoid using abrasive cleaners, scouring pads, or harsh chemicals, as these can damage the finish and sensor.
  • Periodically wipe the sensor window to ensure clear detection.
Devant view of Sloan SF-2150 Faucet showing the aerator and sensor
Figure 6.1 : Face avant view of the faucet, showing the aerator and sensor area for cleaning.

6.2. Remplacement de la batterie

When the batteries are low, the faucet may exhibit inconsistent operation or stop working. Replace all four AA batteries simultaneously with new alkaline batteries.

  1. Coupez l'alimentation en eau du robinet.
  2. Locate the control box under the sink.
  3. Ouvrez le compartiment à piles.
  4. Retirez les piles usagées et jetez-les correctement.
  5. Insérez quatre piles alcalines AA neuves en respectant la polarité.
  6. Fermez soigneusement le compartiment à piles.
  7. Turn on the water supply and test the faucet.

6.3. Filtered Solenoid Maintenance

The control box contains a filtered solenoid valve with a serviceable strainer filter. If water flow is reduced or inconsistent, the filter may need cleaning.

  1. Coupez l'alimentation en eau du robinet.
  2. Carefully disconnect the water lines from the solenoid valve within the control box.
  3. Remove the strainer filter.
  4. Rinse the filter under running water to remove any debris. If heavily clogged, a soft brush may be used.
  5. Reinsert the clean filter and reconnect the water lines, ensuring all connections are tight to prevent leaks.
  6. Turn on the water supply and test the faucet.

7. Dépannage

This section addresses common issues you might encounter with your SF-2150 faucet.

ProblèmeCause possibleSolution
No water flow when sensor is activated.
  • L'alimentation en eau est coupée.
  • Piles faibles ou mortes.
  • Clogged solenoid filter.
  • Sensor cable disconnected.
  • Vérifiez la vanne d'alimentation en eau principale.
  • Remplacez les piles (Section 6.2).
  • Clean solenoid filter (Section 6.3).
  • Verify sensor cable connection to control box.
L'eau coule en continu.
  • Capteur obstrué ou sale.
  • Sensor range too sensitive.
  • Dysfonctionnement de l'électrovanne.
  • Nettoyer la vitre du capteur.
  • Adjust sensor range (Section 5.2).
  • Contact technical support if solenoid is suspected.
Inconsistent sensor activation.
  • Piles faibles.
  • Sensor window dirty.
  • Interférences de la lumière ambiante.
  • Sensor range needs adjustment.
  • Remplacez les piles (Section 6.2).
  • Nettoyer la vitre du capteur.
  • Ensure no direct light sources interfere with the sensor.
  • Adjust sensor range (Section 5.2).
Débit d'eau réduit.
  • Aérateur obstrué.
  • Clogged solenoid filter.
  • Remove and clean the aerator at the faucet spout.
  • Clean solenoid filter (Section 6.3).

8. Spécifications

FonctionnalitéDétail
ModèleSF-2150
MarqueSloan
Type de montageMontage sur le pont
Type de finitionChrome poli
MatérielLaiton
Débit maximal0.5 gallons par minute (GPM)
Source d'énergie4 piles AA (incluses)
Type de capteurInfrared (Adjustable Range)
Longueur du tuyau24 pouces (tuyau flexible)
Longueur du câble du capteur36 pouces
Dimensions du produit3.88"P x 1.5"L x 4.5"H
Poids de l'article5 livres
ConformitéConforme ADA

9. Garantie et assistance

9.1. Garantie limitée

The Sloan SF-2150 Sensor Activated Touch-Free Faucet is covered by a Garantie limitée de 1 ans from the date of purchase. This warranty covers defects in materials and workmanship under normal use and service. For full warranty details, please refer to the official Sloan warranty documentation or contact customer support.

9.2. Assistance technique

For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact Sloan Technical Support:

  • Téléphone: 1-888-756-2614
  • Website: www.sloan.com (for product information and additional resources)