Introduction
This manual provides detailed instructions for the proper use and maintenance of your Apera Instruments Salt20 Salinity Tester Kit. The Salt20 is designed for professional salinity measurement in various water solutions, including pools, spas, agriculture, and environmental monitoring.
Pour des performances optimales et une durée de vie prolongée de votre appareil, veuillez lire attentivement ce manuel avant utilisation.

The Apera Instruments Salt20 Salinity Tester is suitable for a wide range of applications including hydroponics, pools, and drinking water analysis.
Précautions de sécurité
Informations importantes sur la sécurité
- Always handle the device with care to prevent damage to the sensor.
- Do not immerse the entire meter in water beyond the specified IP67 waterproof rating.
- Keep calibration solutions and the device out of reach of children.
- Rangez l'appareil dans un endroit frais et sec lorsqu'il n'est pas utilisé.
- Ensure the battery compartment is sealed properly to maintain water resistance.
Produit terminéview
Composants du kit

The Salt20 Salinity Tester Kit includes the meter, calibration solution, AAA batteries, and a lanyard, all housed in a portable carrying case.
The Apera Instruments Salt20 Salinity Tester Kit includes:
- Salt20 Salinity Tester
- 1 bottle of calibration solution (12.88 mS/cm, equivalent to 6.44 ppt)
- AAA batteries (pre-installed or included)
- Cordon
- Étui de transport portable
Caractéristiques principales
- Haute précision : Apera's unique platinum black sensor (BPB) ensures high accuracy in a wide-range salinity measurement (0 to 10.0 ppt).
- Easy Auto Calibration: 1-point auto calibration with auto buffer recognition.
- Compensation automatique de la température (ATC) : 0-50°C ATC for precise readings.
- Écran LCD clair : Large LCD with dual display of salinity (ppt) and temperature (°C/°F), including reminders for stable readings and completed calibrations.
- Conception imperméable à l'eau: IP67 water-resistant and floatable for durability.
- Longue durée de vie de la batterie : Up to 1000 hours of operation powered by AAA batteries.
- Autodiagnostic : With out-of-range and low battery warnings.
Techniques de détection

The Salt20 features Apera's unique Brush-Resistant Platinum Black (BPB) sensor, designed for high accuracy and consistency in wide-range salinity testing.
Détails de l'écran LCD

The clear LCD display provides simultaneous readings for salinity (ppt) and temperature, along with indicators for stable readings and successful calibration.
Accessoires

A lanyard is included for convenient and secure use of the Salt20 Salinity Tester.

The complete test kit comes in a rugged carrying case for protection and portability.
Installation
Installation de la batterie
The Salt20 Salinity Tester is powered by 4 AAA batteries.
- Unscrew the battery cap at the top of the meter.
- Insert the AAA batteries according to the polarity indicators (+/-).
- Securely screw the battery cap back on to ensure the waterproof seal.
Préparation initiale
- Retirez le capuchon de protection du capteur.
- Rinse the sensor with distilled water and gently shake off excess water.
- The meter is now ready for calibration or measurement.
Mode d'emploi
Mesure de base
- Allumer: Short press the MEAS button to turn on the meter.
- Immerse Sensor: Dip the sensor into the sample solution, ensuring the solution covers the sensor completely. Stir gently to remove air bubbles.
- Lire la mesure : Wait for the smiley face icon to appear and remain stable on the LCD, indicating a stable reading. Record the salinity (ppt) and temperature (°C/°F) values.
- Éteindre: Long press the MEAS button to turn off the meter.
Changement d'unités
To switch between °C and °F, with the meter turned off, long press the CAL button until the unit changes.
Vidéo officielle du produit
Watch this official video from Apera Instruments for a visual guide on using the Salt20 Salinity Tester Kit. This video provides an overview des caractéristiques et du fonctionnement de base du produit.
Étalonnage
1-Point Auto Calibration
The Salt20 Salinity Tester uses a 1-point auto calibration process with auto buffer recognition. It is recommended to calibrate the meter regularly for accurate results, especially before critical measurements or if the meter has not been used for a long time.

The Salt20 Salinity Tester features effortless single-button auto calibration with auto buffer recognition, simplifying the calibration process.
- Préparer la solution : Pour a small amount of the 12.88 mS/cm (6.44 ppt) calibration solution into a clean beaker.
- Entrer en mode d'étalonnage : With the meter turned on, short press the CAL button. The display will show "CAL" and the calibration value.
- Immerse Sensor: Dip the sensor into the calibration solution. Stir gently.
- Attendez la stabilité : The meter will automatically recognize the calibration solution. Wait for the smiley face icon to appear and remain stable. The calibration success symbol (M) will also appear.
- Étalonnage de sortie : Short press the MEAS button to exit calibration mode and return to measurement mode.
Note: Always use fresh calibration solution for each calibration. Do not pour used solution back into the bottle.
Entretien
Nettoyage du capteur
The BPB (Brush-Resistant Platinum Black) sensor is robust but requires proper cleaning to maintain accuracy.
- After each use, rinse the sensor thoroughly with distilled or deionized water.
- If there is visible contamination, gently brush the sensor with a soft brush (like a soft toothbrush) while rinsing.
- For stubborn deposits, soak the sensor in a mild detergent solution for 10-15 minutes, then rinse thoroughly.
- Jamais wipe the sensor with abrasive materials or apply excessive force, as this can damage the platinum black coating.
Stockage
For long-term storage, ensure the sensor is clean and dry. Replace the protective cap. Store the meter in its carrying case in a cool, dry place.
Dépannage
Problèmes courants et solutions
| Problème | Cause possible | Solution |
|---|---|---|
| Lectures inexactes | Sensor dirty; Calibration needed; Expired calibration solution | Clean sensor; Perform calibration; Use fresh calibration solution |
| No Display / Meter Won't Turn On | Batteries déchargées ; installation de batterie incorrecte | Remplacez les piles ; vérifiez la polarité des piles. |
| "Out-of-Range" Warning | Salinity level exceeds 10.0 ppt | The meter's range is 0-10.0 ppt. For higher ranges, a different meter is required. |
| Réponse lente | Le capteur doit être nettoyé | Clean the sensor thoroughly |
Caractéristiques
Spécifications techniques
| Paramètre | Valeur |
|---|---|
| Gamme de salinité | 0 - 10.0 ppt |
| Salinity Accuracy | ± 1% PE |
| Plage de température | 0 - 50°C (32 - 122°F) |
| Compensation de température | Automatic (0-50°C) |
| Étalonnage | Auto 1-point |
| Alimentation électrique | 4 piles AAA |
| Autonomie de la batterie | Jusqu'à 1000 XNUMX heures |
| Indice d'étanchéité | IP67 (Dust-proof and Water-proof, Floatable) |
| Arrêt automatique | 8 minutes sans opération |
| Dimensions | 7.01 x 1.61 x 1.18 pouces |
| Poids | 3.8 onces |
Garantie et assistance
Informations sur la garantie
Apera Instruments provides a limited warranty for its products. Please refer to the official Apera Instruments webConsultez le site web ou la carte de garantie fournie avec votre produit pour connaître les conditions générales de garantie.
Assistance clientèle
For technical assistance, troubleshooting, or inquiries about replacement parts and accessories, please contact Apera Instruments customer support.
Website: www.aperainst.com
E-mail: Refer to your product documentation for specific contact email.
Téléphone: Refer to your product documentation for specific contact phone number.