Introduction

This manual provides detailed instructions for the proper use and maintenance of your Apera Instruments Salt20 Salinity Tester Kit. The Salt20 is designed for professional salinity measurement in various water solutions, including pools, spas, agriculture, and environmental monitoring.

Pour des performances optimales et une durée de vie prolongée de votre appareil, veuillez lire attentivement ce manuel avant utilisation.

Apera Instruments Salt20 Salinity Tester Kit showing applications in hydroponics, pools, and drinking water.

The Apera Instruments Salt20 Salinity Tester is suitable for a wide range of applications including hydroponics, pools, and drinking water analysis.

Précautions de sécurité

Informations importantes sur la sécurité

Produit terminéview

Composants du kit

Apera Instruments Salt20 Salinity Tester Kit with meter, calibration solution, and carrying case.

The Salt20 Salinity Tester Kit includes the meter, calibration solution, AAA batteries, and a lanyard, all housed in a portable carrying case.

The Apera Instruments Salt20 Salinity Tester Kit includes:

Caractéristiques principales

Techniques de détection

Close-up of the Apera Instruments Salt20 BPB EC sensor.

The Salt20 features Apera's unique Brush-Resistant Platinum Black (BPB) sensor, designed for high accuracy and consistency in wide-range salinity testing.

Détails de l'écran LCD

Diagram of the Apera Instruments Salt20 LCD display showing measurement values, temperature, stable reading reminder, and calibration success symbol.

The clear LCD display provides simultaneous readings for salinity (ppt) and temperature, along with indicators for stable readings and successful calibration.

Accessoires

Hand holding the Apera Instruments Salt20 Salinity Tester with an attached lanyard.

A lanyard is included for convenient and secure use of the Salt20 Salinity Tester.

Person holding the rugged carrying case for the Apera Instruments Salt20 Salinity Tester Kit.

The complete test kit comes in a rugged carrying case for protection and portability.

Installation

Installation de la batterie

The Salt20 Salinity Tester is powered by 4 AAA batteries.

  1. Unscrew the battery cap at the top of the meter.
  2. Insert the AAA batteries according to the polarity indicators (+/-).
  3. Securely screw the battery cap back on to ensure the waterproof seal.

Préparation initiale

  1. Retirez le capuchon de protection du capteur.
  2. Rinse the sensor with distilled water and gently shake off excess water.
  3. The meter is now ready for calibration or measurement.

Mode d'emploi

Mesure de base

  1. Allumer: Short press the MEAS button to turn on the meter.
  2. Immerse Sensor: Dip the sensor into the sample solution, ensuring the solution covers the sensor completely. Stir gently to remove air bubbles.
  3. Lire la mesure : Wait for the smiley face icon to appear and remain stable on the LCD, indicating a stable reading. Record the salinity (ppt) and temperature (°C/°F) values.
  4. Éteindre: Long press the MEAS button to turn off the meter.

Changement d'unités

To switch between °C and °F, with the meter turned off, long press the CAL button until the unit changes.

Vidéo officielle du produit

Watch this official video from Apera Instruments for a visual guide on using the Salt20 Salinity Tester Kit. This video provides an overview des caractéristiques et du fonctionnement de base du produit.

Étalonnage

1-Point Auto Calibration

The Salt20 Salinity Tester uses a 1-point auto calibration process with auto buffer recognition. It is recommended to calibrate the meter regularly for accurate results, especially before critical measurements or if the meter has not been used for a long time.

Diagram showing the calibration process for the Apera Instruments Salt20 Salinity Tester.

The Salt20 Salinity Tester features effortless single-button auto calibration with auto buffer recognition, simplifying the calibration process.

  1. Préparer la solution : Pour a small amount of the 12.88 mS/cm (6.44 ppt) calibration solution into a clean beaker.
  2. Entrer en mode d'étalonnage : With the meter turned on, short press the CAL button. The display will show "CAL" and the calibration value.
  3. Immerse Sensor: Dip the sensor into the calibration solution. Stir gently.
  4. Attendez la stabilité : The meter will automatically recognize the calibration solution. Wait for the smiley face icon to appear and remain stable. The calibration success symbol (M) will also appear.
  5. Étalonnage de sortie : Short press the MEAS button to exit calibration mode and return to measurement mode.

Note: Always use fresh calibration solution for each calibration. Do not pour used solution back into the bottle.

Entretien

Nettoyage du capteur

The BPB (Brush-Resistant Platinum Black) sensor is robust but requires proper cleaning to maintain accuracy.

  1. After each use, rinse the sensor thoroughly with distilled or deionized water.
  2. If there is visible contamination, gently brush the sensor with a soft brush (like a soft toothbrush) while rinsing.
  3. For stubborn deposits, soak the sensor in a mild detergent solution for 10-15 minutes, then rinse thoroughly.
  4. Jamais wipe the sensor with abrasive materials or apply excessive force, as this can damage the platinum black coating.

Stockage

For long-term storage, ensure the sensor is clean and dry. Replace the protective cap. Store the meter in its carrying case in a cool, dry place.

Dépannage

Problèmes courants et solutions

ProblèmeCause possibleSolution
Lectures inexactesSensor dirty; Calibration needed; Expired calibration solutionClean sensor; Perform calibration; Use fresh calibration solution
No Display / Meter Won't Turn OnBatteries déchargées ; installation de batterie incorrecteRemplacez les piles ; vérifiez la polarité des piles.
"Out-of-Range" WarningSalinity level exceeds 10.0 pptThe meter's range is 0-10.0 ppt. For higher ranges, a different meter is required.
Réponse lenteLe capteur doit être nettoyéClean the sensor thoroughly

Caractéristiques

Spécifications techniques

ParamètreValeur
Gamme de salinité0 - 10.0 ppt
Salinity Accuracy± 1% PE
Plage de température0 - 50°C (32 - 122°F)
Compensation de températureAutomatic (0-50°C)
ÉtalonnageAuto 1-point
Alimentation électrique4 piles AAA
Autonomie de la batterieJusqu'à 1000 XNUMX heures
Indice d'étanchéitéIP67 (Dust-proof and Water-proof, Floatable)
Arrêt automatique8 minutes sans opération
Dimensions7.01 x 1.61 x 1.18 pouces
Poids3.8 onces

Garantie et assistance

Informations sur la garantie

Apera Instruments provides a limited warranty for its products. Please refer to the official Apera Instruments webConsultez le site web ou la carte de garantie fournie avec votre produit pour connaître les conditions générales de garantie.

Assistance clientèle

For technical assistance, troubleshooting, or inquiries about replacement parts and accessories, please contact Apera Instruments customer support.

Website: www.aperainst.com

E-mail: Refer to your product documentation for specific contact email.

Téléphone: Refer to your product documentation for specific contact phone number.

Documents connexes - AI214

Préview Manuel d'utilisation du testeur de salinité de poche Salt20 d'Apera Instruments
Manuel d'instructions du testeur de salinité de poche Apera Instruments Salt20, couvrant l'installation de la batterie, les fonctions du clavier, l'étalonnage, la mesure de la salinité, les spécifications techniques et les informations sur la garantie.
Préview Manuel d'utilisation du testeur de salinité de poche SALT20 - Apera Instruments
Manuel d'utilisation du testeur de salinité de poche Apera Instruments SALT20, couvrant l'installation, le fonctionnement, l'étalonnage, les spécifications techniques et les informations de garantie fournies par Labco Scientific.
Préview Apera Instruments PC60 & PH20 Pocket Tester User Manuals
Comprehensive user manuals for Apera Instruments PC60 Premium Series 5-in-1 Multi-Parameter Pocket Tester and PH20 Value Series pH Tester Kit. Includes setup, calibration, measurement, troubleshooting, and specifications.
Préview Manuel d'utilisation du testeur 5 en 1 Apera Instruments PC60 Premium
Manuel d'utilisation complet du testeur 5 en 1 PC60 Premium d'Apera Instruments, couvrant les mesures de pH, de conductivité, de TDS, de salinité et de température. Inclut l'installation, l'étalonnage, le fonctionnement, la maintenance et le dépannage.
Préview Apera Instruments 5052 Seawater Salinity Pocket Tester Operation Manual
Detailed operation manual for the Apera Instruments 5052 Seawater Salinity Pocket Tester, covering technical parameters, calibration, measurement procedures, important notes, and warranty information.
Préview Testeur de conductivité de poche Apera EC20 : Manuel d’instructions et guide
Manuel d'utilisation complet du testeur de conductivité de poche Apera EC20. Découvrez la configuration, l'étalonnage, la mesure de la conductivité, les spécifications techniques et les informations relatives à la garantie.