1. Introduction
This manual provides essential information for the proper use and care of your Amphenol MS-156 RG316 Coaxial Cable. This high-quality cable is designed for reliable signal transmission in various applications, particularly for testing and measuring RF signals. It features an MS-156 plug male connector on one end and an SMA male right-angle connector on the other, with a length of 15cm (6 inches).
Veuillez lire attentivement ce manuel avant d'utiliser le produit afin d'en garantir des performances et une durée de vie optimales.

Cette image montre le Amphenol MS-156 RG316 coaxial cable. One end features an MS-156 plug male connector, and the other end has an SMA male right-angle connector. The cable is black and approximately 15cm (6 inches) long.
2. Installation
Le Amphenol MS-156 RG316 cable is designed for straightforward connection between compatible devices. Follow these steps for proper setup:
- Identifier les connecteurs : Locate the MS-156 plug male connector and the SMA male right-angle connector on the cable.
- Vérifiez la compatibilité de l'appareil : Ensure that your devices have corresponding female MS-156 and SMA ports.
- Connect MS-156 End: Gently insert the MS-156 plug male connector into the appropriate port on your first device. Ensure it seats firmly.
- Connect SMA End: Carefully align the SMA male right-angle connector with the SMA female port on your second device. Screw the connector clockwise until it is finger-tight. Ne pas trop serrer, as this can damage the connector or port.
- Vérifiez la connexion : Ensure both ends are securely connected and there is no visible gap or looseness.
3. Fonctionnement
Une fois que le Amphenol MS-156 RG316 cable is properly connected, it functions as a passive conduit for RF signals. Its operation is dependent on the devices it connects. Ensure that the devices are powered on and configured correctly according to their respective manuals.
- Transmission du signal: The cable will transmit RF signals between the connected devices.
- Testing and Measurement: When used as a test probe, ensure the cable is connected to appropriate test equipment and the device under test.
- Considérations environnementales : The cable is suitable for both indoor and outdoor use. However, avoid exposing connectors to excessive moisture or extreme temperatures to prevent signal degradation or damage.
4. Entretien
Proper maintenance will extend the lifespan and ensure the consistent performance of your Amphenol MS-156 RG316 cable.
- Manipulation des câbles : Avoid sharp bends, kinks, or excessive pulling on the cable, as this can damage the internal conductor and shielding, leading to signal loss.
- Entretien des connecteurs : Keep the connectors clean and free from dust, dirt, or moisture. Use a clean, dry, lint-free cloth to gently wipe the connector surfaces if necessary. Avoid using abrasive materials or harsh chemicals.
- Stockage: When not in use, store the cable coiled loosely in a dry, cool environment, away from direct sunlight and extreme temperatures. Avoid placing heavy objects on the cable.
- Inspection: Inspectez régulièrement le câble et les connecteurs afin de déceler tout signe d'usure, de dommage ou de corrosion. Remplacez le câble si vous constatez des dommages.
5. Dépannage
Si vous rencontrez des problèmes de transmission du signal, veuillez suivre les étapes de dépannage suivantes :
- Absence de signal ou signal intermittent :
- Vérifier les connexions : Ensure both the MS-156 and SMA connectors are securely and correctly attached to their respective ports.
- Inspecter le câble pour détecter tout dommage : Look for any visible cuts, kinks, or severe bends in the cable jacket. Internal damage may not be visible but can cause signal loss.
- Connecteurs propres : Dust or debris on the connector pins can interfere with signal transmission. Gently clean the connectors as described in the Maintenance section.
- Testez avec un autre câble : If possible, try using a known working cable to rule out issues with the devices themselves.
- Mauvaise qualité du signal :
- Ensure Correct Cable Type: Verify that an RG316 cable is appropriate for your application and frequency range.
- Minimiser les interférences : Keep the cable away from sources of electromagnetic interference (EMI) such as power cables, motors, or other electronic devices.
If problems persist after following these steps, consult the manuals for your connected devices or seek professional assistance.
6. Spécifications
| Fonctionnalité | Spécification |
|---|---|
| Marque | Amphénol |
| Modèle | MS-156 |
| Type de câble | RG-316 |
| Utilisations recommandées | Testing and measuring RF signals |
| Connecteur Sexe | Male-to-Male (MS-156 Plug Male to SMA Male Angle RA) |
| Longueur | 15 cm (6 pouces) |
| Couleur | Noir |
| Utilisation intérieure/extérieure | Intérieur, extérieur |
| Poids de l'article | 0.01 onces |
7. Informations sur la garantie
Détails spécifiques de la garantie pour le Amphenol MS-156 RG316 Coaxial Cable are not provided in the product information available. For warranty inquiries, please refer to the retailer or manufacturer's official website où le produit a été acheté.
8. Assistance
For technical support or further assistance with your Amphenol MS-156 RG316 Coaxial Cable, please contact the vendor or manufacturer directly. Contact information is typically available on their official websites or through your purchase documentation.